Cargando…
Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system
PURPOSE: To develop and assess a three-dimensional (3D) self-gated technique for the evaluation of myocardial infarction (MI) in mouse model without the use of external electrocardiogram (ECG) trigger and respiratory motion sensor on a 3T clinical MR system. METHODS: A 3D T1-weighted GRE sequence wi...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720776/ https://www.ncbi.nlm.nih.gov/pubmed/29216303 http://dx.doi.org/10.1371/journal.pone.0189286 |
_version_ | 1783284728237916160 |
---|---|
author | Zhang, Xiaoyong Qiu, Bensheng Wei, Zijun Yan, Fei Shi, Caiyun Su, Shi Liu, Xin Ji, Jim X. Xie, Guoxi |
author_facet | Zhang, Xiaoyong Qiu, Bensheng Wei, Zijun Yan, Fei Shi, Caiyun Su, Shi Liu, Xin Ji, Jim X. Xie, Guoxi |
author_sort | Zhang, Xiaoyong |
collection | PubMed |
description | PURPOSE: To develop and assess a three-dimensional (3D) self-gated technique for the evaluation of myocardial infarction (MI) in mouse model without the use of external electrocardiogram (ECG) trigger and respiratory motion sensor on a 3T clinical MR system. METHODS: A 3D T1-weighted GRE sequence with stack-of-stars sampling trajectories was developed and performed on six mice with MIs that were injected with a gadolinium-based contrast agent at a 3T clinical MR system. Respiratory and cardiac self-gating signals were derived from the Cartesian mapping of the k-space center along the partition encoding direction by bandpass filtering in image domain. The data were then realigned according to the predetermined self-gating signals for the following image reconstruction. In order to accelerate the data acquisition, image reconstruction was based on compressed sensing (CS) theory by exploiting temporal sparsity of the reconstructed images. In addition, images were also reconstructed from the same realigned data by conventional regridding method for demonstrating the advantageous of the proposed reconstruction method. Furthermore, the accuracy of detecting MI by the proposed method was assessed using histological analysis as the standard reference. Linear regression and Bland-Altman analysis were used to assess the agreement between the proposed method and the histological analysis. RESULTS: Compared to the conventional regridding method, the proposed CS method reconstructed images with much less streaking artifact, as well as a better contrast-to-noise ratio (CNR) between the blood and myocardium (4.1 ± 2.1 vs. 2.9 ± 1.1, p = 0.031). Linear regression and Bland-Altman analysis demonstrated that excellent correlation was obtained between infarct sizes derived from the proposed method and histology analysis. CONCLUSION: A 3D T1-weighted self-gating technique for mouse cardiac imaging was developed, which has potential for accurately evaluating MIs in mice at 3T clinical MR system without the use of external ECG trigger and respiratory motion sensor. |
format | Online Article Text |
id | pubmed-5720776 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-57207762017-12-15 Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system Zhang, Xiaoyong Qiu, Bensheng Wei, Zijun Yan, Fei Shi, Caiyun Su, Shi Liu, Xin Ji, Jim X. Xie, Guoxi PLoS One Research Article PURPOSE: To develop and assess a three-dimensional (3D) self-gated technique for the evaluation of myocardial infarction (MI) in mouse model without the use of external electrocardiogram (ECG) trigger and respiratory motion sensor on a 3T clinical MR system. METHODS: A 3D T1-weighted GRE sequence with stack-of-stars sampling trajectories was developed and performed on six mice with MIs that were injected with a gadolinium-based contrast agent at a 3T clinical MR system. Respiratory and cardiac self-gating signals were derived from the Cartesian mapping of the k-space center along the partition encoding direction by bandpass filtering in image domain. The data were then realigned according to the predetermined self-gating signals for the following image reconstruction. In order to accelerate the data acquisition, image reconstruction was based on compressed sensing (CS) theory by exploiting temporal sparsity of the reconstructed images. In addition, images were also reconstructed from the same realigned data by conventional regridding method for demonstrating the advantageous of the proposed reconstruction method. Furthermore, the accuracy of detecting MI by the proposed method was assessed using histological analysis as the standard reference. Linear regression and Bland-Altman analysis were used to assess the agreement between the proposed method and the histological analysis. RESULTS: Compared to the conventional regridding method, the proposed CS method reconstructed images with much less streaking artifact, as well as a better contrast-to-noise ratio (CNR) between the blood and myocardium (4.1 ± 2.1 vs. 2.9 ± 1.1, p = 0.031). Linear regression and Bland-Altman analysis demonstrated that excellent correlation was obtained between infarct sizes derived from the proposed method and histology analysis. CONCLUSION: A 3D T1-weighted self-gating technique for mouse cardiac imaging was developed, which has potential for accurately evaluating MIs in mice at 3T clinical MR system without the use of external ECG trigger and respiratory motion sensor. Public Library of Science 2017-12-07 /pmc/articles/PMC5720776/ /pubmed/29216303 http://dx.doi.org/10.1371/journal.pone.0189286 Text en © 2017 Zhang et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Zhang, Xiaoyong Qiu, Bensheng Wei, Zijun Yan, Fei Shi, Caiyun Su, Shi Liu, Xin Ji, Jim X. Xie, Guoxi Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system |
title | Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system |
title_full | Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system |
title_fullStr | Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system |
title_full_unstemmed | Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system |
title_short | Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system |
title_sort | three-dimensional self-gated cardiac mr imaging for the evaluation of myocardial infarction in mouse model on a 3t clinical mr system |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720776/ https://www.ncbi.nlm.nih.gov/pubmed/29216303 http://dx.doi.org/10.1371/journal.pone.0189286 |
work_keys_str_mv | AT zhangxiaoyong threedimensionalselfgatedcardiacmrimagingfortheevaluationofmyocardialinfarctioninmousemodelona3tclinicalmrsystem AT qiubensheng threedimensionalselfgatedcardiacmrimagingfortheevaluationofmyocardialinfarctioninmousemodelona3tclinicalmrsystem AT weizijun threedimensionalselfgatedcardiacmrimagingfortheevaluationofmyocardialinfarctioninmousemodelona3tclinicalmrsystem AT yanfei threedimensionalselfgatedcardiacmrimagingfortheevaluationofmyocardialinfarctioninmousemodelona3tclinicalmrsystem AT shicaiyun threedimensionalselfgatedcardiacmrimagingfortheevaluationofmyocardialinfarctioninmousemodelona3tclinicalmrsystem AT sushi threedimensionalselfgatedcardiacmrimagingfortheevaluationofmyocardialinfarctioninmousemodelona3tclinicalmrsystem AT liuxin threedimensionalselfgatedcardiacmrimagingfortheevaluationofmyocardialinfarctioninmousemodelona3tclinicalmrsystem AT jijimx threedimensionalselfgatedcardiacmrimagingfortheevaluationofmyocardialinfarctioninmousemodelona3tclinicalmrsystem AT xieguoxi threedimensionalselfgatedcardiacmrimagingfortheevaluationofmyocardialinfarctioninmousemodelona3tclinicalmrsystem |