Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice
BACKGROUND: The complication of vein patch rupture is well described after carotid patch angioplasty; however, there is a paucity of data about the safety of vein patch closure in the setting of femoral endarterectomy. METHODS/RESULTS: From May 2012 to May 2015, 115 femoral endarterectomies with pat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5721262/ https://www.ncbi.nlm.nih.gov/pubmed/29234736 http://dx.doi.org/10.1016/j.ejvssr.2017.10.001 |
_version_ | 1783284772589535232 |
---|---|
author | Berner, M. Lattmann, Th. Stalder, Ph. Wigger, P. |
author_facet | Berner, M. Lattmann, Th. Stalder, Ph. Wigger, P. |
author_sort | Berner, M. |
collection | PubMed |
description | BACKGROUND: The complication of vein patch rupture is well described after carotid patch angioplasty; however, there is a paucity of data about the safety of vein patch closure in the setting of femoral endarterectomy. METHODS/RESULTS: From May 2012 to May 2015, 115 femoral endarterectomies with patch closure were performed. A patch rupture occurred in three cases (2.6%) with a mortality rate of 66% (2/3). In all cases the greater saphenous vein below the knee was used as patch material. DISCUSSION/CONCLUSION: Vein patches, particularly from small calibre veins, should be excluded in femoral endarterectomy procedures as they pose a substantial risk of rupture. |
format | Online Article Text |
id | pubmed-5721262 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-57212622017-12-11 Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice Berner, M. Lattmann, Th. Stalder, Ph. Wigger, P. EJVES Short Rep Short Report BACKGROUND: The complication of vein patch rupture is well described after carotid patch angioplasty; however, there is a paucity of data about the safety of vein patch closure in the setting of femoral endarterectomy. METHODS/RESULTS: From May 2012 to May 2015, 115 femoral endarterectomies with patch closure were performed. A patch rupture occurred in three cases (2.6%) with a mortality rate of 66% (2/3). In all cases the greater saphenous vein below the knee was used as patch material. DISCUSSION/CONCLUSION: Vein patches, particularly from small calibre veins, should be excluded in femoral endarterectomy procedures as they pose a substantial risk of rupture. Elsevier 2017-11-07 /pmc/articles/PMC5721262/ /pubmed/29234736 http://dx.doi.org/10.1016/j.ejvssr.2017.10.001 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Short Report Berner, M. Lattmann, Th. Stalder, Ph. Wigger, P. Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice |
title | Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice |
title_full | Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice |
title_fullStr | Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice |
title_full_unstemmed | Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice |
title_short | Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice |
title_sort | vein patch closure using below the knee greater saphenous vein for femoral endarterectomy procedures is not always a safe choice |
topic | Short Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5721262/ https://www.ncbi.nlm.nih.gov/pubmed/29234736 http://dx.doi.org/10.1016/j.ejvssr.2017.10.001 |
work_keys_str_mv | AT bernerm veinpatchclosureusingbelowthekneegreatersaphenousveinforfemoralendarterectomyproceduresisnotalwaysasafechoice AT lattmannth veinpatchclosureusingbelowthekneegreatersaphenousveinforfemoralendarterectomyproceduresisnotalwaysasafechoice AT stalderph veinpatchclosureusingbelowthekneegreatersaphenousveinforfemoralendarterectomyproceduresisnotalwaysasafechoice AT wiggerp veinpatchclosureusingbelowthekneegreatersaphenousveinforfemoralendarterectomyproceduresisnotalwaysasafechoice |