Cargando…
Midterm Results of Cementless and Cemented Unicondylar Knee Arthroplasty with Mobile Meniscal Bearing: A Prospective Cohort Study
BACKGROUND: Cemented unicompartmental knee arthroplasty (UKA) yields good clinical outcome but common revision reasons are loosening and pain. Cementless UKA may reduce the revision rate. OBJECTIVE: The current study was designed to assess clinical and radiographic outcome of cemented and cementless...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bentham Open
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5721307/ https://www.ncbi.nlm.nih.gov/pubmed/29290853 http://dx.doi.org/10.2174/1874325001711011173 |
_version_ | 1783284780801982464 |
---|---|
author | Stempin, Radosław Kaczmarek, Wiesław Stempin, Kacper Dutka, Julian |
author_facet | Stempin, Radosław Kaczmarek, Wiesław Stempin, Kacper Dutka, Julian |
author_sort | Stempin, Radosław |
collection | PubMed |
description | BACKGROUND: Cemented unicompartmental knee arthroplasty (UKA) yields good clinical outcome but common revision reasons are loosening and pain. Cementless UKA may reduce the revision rate. OBJECTIVE: The current study was designed to assess clinical and radiographic outcome of cemented and cementless UKA, using bone quality as determined by the Bone Hardness Test (BHT) as selection criterion for cementless implantation. METHODS: In this prospective comparative cohort study we analyzed 50 cementless and 29 Oxford consecutive UKA cases. Patients with sufficient bone quality were eligible for cementless UKA. Bone quality was assessed with the BHT, which consisted of exercising pressure with the thumb on the bone surface created after resection of the tibia. RESULTS: The average surgical times were 62.5 ± 12.6 and 78 ± 16 minutes in the cementless and the cemented group, respectively (p < 0.01). The average thickness of the polyethylene insert was 4.3 ± 1.2 (range, 3 – 9) and 3.7 ± 0.8 (range, 3 – 6) mm, respectively (p = 0.02). Both types of implants yielded excellent clinical and functional results. At an average follow-up time of seven years, we found non-significant differences between clinical results of cementless versus cemented implants. CONCLUSION: Shorter surgical time makes cementless implantation more attractive to surgeons when considering UKA options for their patients. The average thickness of the polyethylene insert in cementless group was 0.6 mm thinner than in the cemented group. The BHT is a simple and useful test to assess whether patients are eligible for cementless UKA. |
format | Online Article Text |
id | pubmed-5721307 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Bentham Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-57213072017-12-29 Midterm Results of Cementless and Cemented Unicondylar Knee Arthroplasty with Mobile Meniscal Bearing: A Prospective Cohort Study Stempin, Radosław Kaczmarek, Wiesław Stempin, Kacper Dutka, Julian Open Orthop J Article BACKGROUND: Cemented unicompartmental knee arthroplasty (UKA) yields good clinical outcome but common revision reasons are loosening and pain. Cementless UKA may reduce the revision rate. OBJECTIVE: The current study was designed to assess clinical and radiographic outcome of cemented and cementless UKA, using bone quality as determined by the Bone Hardness Test (BHT) as selection criterion for cementless implantation. METHODS: In this prospective comparative cohort study we analyzed 50 cementless and 29 Oxford consecutive UKA cases. Patients with sufficient bone quality were eligible for cementless UKA. Bone quality was assessed with the BHT, which consisted of exercising pressure with the thumb on the bone surface created after resection of the tibia. RESULTS: The average surgical times were 62.5 ± 12.6 and 78 ± 16 minutes in the cementless and the cemented group, respectively (p < 0.01). The average thickness of the polyethylene insert was 4.3 ± 1.2 (range, 3 – 9) and 3.7 ± 0.8 (range, 3 – 6) mm, respectively (p = 0.02). Both types of implants yielded excellent clinical and functional results. At an average follow-up time of seven years, we found non-significant differences between clinical results of cementless versus cemented implants. CONCLUSION: Shorter surgical time makes cementless implantation more attractive to surgeons when considering UKA options for their patients. The average thickness of the polyethylene insert in cementless group was 0.6 mm thinner than in the cemented group. The BHT is a simple and useful test to assess whether patients are eligible for cementless UKA. Bentham Open 2017-10-31 /pmc/articles/PMC5721307/ /pubmed/29290853 http://dx.doi.org/10.2174/1874325001711011173 Text en © 2017 Stempin et al. https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Article Stempin, Radosław Kaczmarek, Wiesław Stempin, Kacper Dutka, Julian Midterm Results of Cementless and Cemented Unicondylar Knee Arthroplasty with Mobile Meniscal Bearing: A Prospective Cohort Study |
title | Midterm Results of Cementless and Cemented Unicondylar Knee Arthroplasty with Mobile Meniscal Bearing: A Prospective Cohort Study |
title_full | Midterm Results of Cementless and Cemented Unicondylar Knee Arthroplasty with Mobile Meniscal Bearing: A Prospective Cohort Study |
title_fullStr | Midterm Results of Cementless and Cemented Unicondylar Knee Arthroplasty with Mobile Meniscal Bearing: A Prospective Cohort Study |
title_full_unstemmed | Midterm Results of Cementless and Cemented Unicondylar Knee Arthroplasty with Mobile Meniscal Bearing: A Prospective Cohort Study |
title_short | Midterm Results of Cementless and Cemented Unicondylar Knee Arthroplasty with Mobile Meniscal Bearing: A Prospective Cohort Study |
title_sort | midterm results of cementless and cemented unicondylar knee arthroplasty with mobile meniscal bearing: a prospective cohort study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5721307/ https://www.ncbi.nlm.nih.gov/pubmed/29290853 http://dx.doi.org/10.2174/1874325001711011173 |
work_keys_str_mv | AT stempinradosław midtermresultsofcementlessandcementedunicondylarkneearthroplastywithmobilemeniscalbearingaprospectivecohortstudy AT kaczmarekwiesław midtermresultsofcementlessandcementedunicondylarkneearthroplastywithmobilemeniscalbearingaprospectivecohortstudy AT stempinkacper midtermresultsofcementlessandcementedunicondylarkneearthroplastywithmobilemeniscalbearingaprospectivecohortstudy AT dutkajulian midtermresultsofcementlessandcementedunicondylarkneearthroplastywithmobilemeniscalbearingaprospectivecohortstudy |