Cargando…
Is daily computed tomography image guidance necessary for nasal cavity and nasopharyngeal radiotherapy? An investigation based on helical tomotherapy
To analyze the magnitude of setup errors corrected by helical tomotherapy megavoltage computed tomography (MVCT) on a daily or weekly basis and the impact of those corrections on the delivered dose to the tumor and organs at risk (OARs), we retrospectively analyzed the setup errors for 6 nasal cavit...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5721532/ https://www.ncbi.nlm.nih.gov/pubmed/18449163 http://dx.doi.org/10.1120/jacmp.v9i1.2686 |
_version_ | 1783284825446154240 |
---|---|
author | Sheng, Ke Chow, Jennifer Hunter, Grant Larner, James Read, Paul |
author_facet | Sheng, Ke Chow, Jennifer Hunter, Grant Larner, James Read, Paul |
author_sort | Sheng, Ke |
collection | PubMed |
description | To analyze the magnitude of setup errors corrected by helical tomotherapy megavoltage computed tomography (MVCT) on a daily or weekly basis and the impact of those corrections on the delivered dose to the tumor and organs at risk (OARs), we retrospectively analyzed the setup errors for 6 nasal cavity and 4 nasopharyngeal cancer patients treated with helical tomotherapy for 25 – 33 fractions. Each patient had MVCT‐guided repositioning for all fractions of treatment. The new dose–volume histograms (DVHs) and equivalent uniform doses (EUDs) for the planning target volume (PTV) and OARs were calculated for hypothetical situations in which no imaging guidance (IG) or once‐weekly imaging guidance (WIG) took place. The mean total setup error for treatment without daily IG was [Formula: see text] mm, which could be reduced to [Formula: see text] mm if WIG were to be performed. The geometric uncertainties from the absence of IG resulted in a reduction of mean PTV EUD by [Formula: see text] , which could be reduced to [Formula: see text] with WIG. The EUDs of the OARs increased to [Formula: see text] Gy or [Formula: see text] Gy without and with WIG respectively. Without daily IG, the mean uncertainty in patient position has a relatively small effect on the mean dosimetry for PTV and OARs, and the use of WIG can further reduce those effects by approximately half. On the other hand, because of the large variance, with low probability, substantial deviation from the original planned dosimetry may occur without IG. Therefore, daily MVCT is preferred as an important safety measure in the delivery of intensity‐modulated radiation therapy. PACS number: 87.53.Dq |
format | Online Article Text |
id | pubmed-5721532 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57215322018-04-02 Is daily computed tomography image guidance necessary for nasal cavity and nasopharyngeal radiotherapy? An investigation based on helical tomotherapy Sheng, Ke Chow, Jennifer Hunter, Grant Larner, James Read, Paul J Appl Clin Med Phys Radiation Oncology Physics To analyze the magnitude of setup errors corrected by helical tomotherapy megavoltage computed tomography (MVCT) on a daily or weekly basis and the impact of those corrections on the delivered dose to the tumor and organs at risk (OARs), we retrospectively analyzed the setup errors for 6 nasal cavity and 4 nasopharyngeal cancer patients treated with helical tomotherapy for 25 – 33 fractions. Each patient had MVCT‐guided repositioning for all fractions of treatment. The new dose–volume histograms (DVHs) and equivalent uniform doses (EUDs) for the planning target volume (PTV) and OARs were calculated for hypothetical situations in which no imaging guidance (IG) or once‐weekly imaging guidance (WIG) took place. The mean total setup error for treatment without daily IG was [Formula: see text] mm, which could be reduced to [Formula: see text] mm if WIG were to be performed. The geometric uncertainties from the absence of IG resulted in a reduction of mean PTV EUD by [Formula: see text] , which could be reduced to [Formula: see text] with WIG. The EUDs of the OARs increased to [Formula: see text] Gy or [Formula: see text] Gy without and with WIG respectively. Without daily IG, the mean uncertainty in patient position has a relatively small effect on the mean dosimetry for PTV and OARs, and the use of WIG can further reduce those effects by approximately half. On the other hand, because of the large variance, with low probability, substantial deviation from the original planned dosimetry may occur without IG. Therefore, daily MVCT is preferred as an important safety measure in the delivery of intensity‐modulated radiation therapy. PACS number: 87.53.Dq John Wiley and Sons Inc. 2008-01-28 /pmc/articles/PMC5721532/ /pubmed/18449163 http://dx.doi.org/10.1120/jacmp.v9i1.2686 Text en © 2008 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Sheng, Ke Chow, Jennifer Hunter, Grant Larner, James Read, Paul Is daily computed tomography image guidance necessary for nasal cavity and nasopharyngeal radiotherapy? An investigation based on helical tomotherapy |
title | Is daily computed tomography image guidance necessary for nasal cavity and nasopharyngeal radiotherapy? An investigation based on helical tomotherapy |
title_full | Is daily computed tomography image guidance necessary for nasal cavity and nasopharyngeal radiotherapy? An investigation based on helical tomotherapy |
title_fullStr | Is daily computed tomography image guidance necessary for nasal cavity and nasopharyngeal radiotherapy? An investigation based on helical tomotherapy |
title_full_unstemmed | Is daily computed tomography image guidance necessary for nasal cavity and nasopharyngeal radiotherapy? An investigation based on helical tomotherapy |
title_short | Is daily computed tomography image guidance necessary for nasal cavity and nasopharyngeal radiotherapy? An investigation based on helical tomotherapy |
title_sort | is daily computed tomography image guidance necessary for nasal cavity and nasopharyngeal radiotherapy? an investigation based on helical tomotherapy |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5721532/ https://www.ncbi.nlm.nih.gov/pubmed/18449163 http://dx.doi.org/10.1120/jacmp.v9i1.2686 |
work_keys_str_mv | AT shengke isdailycomputedtomographyimageguidancenecessaryfornasalcavityandnasopharyngealradiotherapyaninvestigationbasedonhelicaltomotherapy AT chowjennifer isdailycomputedtomographyimageguidancenecessaryfornasalcavityandnasopharyngealradiotherapyaninvestigationbasedonhelicaltomotherapy AT huntergrant isdailycomputedtomographyimageguidancenecessaryfornasalcavityandnasopharyngealradiotherapyaninvestigationbasedonhelicaltomotherapy AT larnerjames isdailycomputedtomographyimageguidancenecessaryfornasalcavityandnasopharyngealradiotherapyaninvestigationbasedonhelicaltomotherapy AT readpaul isdailycomputedtomographyimageguidancenecessaryfornasalcavityandnasopharyngealradiotherapyaninvestigationbasedonhelicaltomotherapy |