Cargando…

Regression modelling combining MRI measurements and patient anthropometry for patient screening and prediction of graft diameter in hamstring autograft arthroscopic ACL reconstruction

BACKGROUND: Previous studies have associated anthropometric data and pre-operative hamstring tendon measurements to intraoperative graft diameter for hamstring autograft ACL reconstruction, although an integrated model has yet to be described. The aim of this study was to present such a predictive m...

Descripción completa

Detalles Bibliográficos
Autores principales: An, Vincent V.G., Scholes, Corey, Mhaskar, Vikram A., Parker, David A., Fritsch, Brett A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Asia-Pacific Knee, Arthroscopy and Sports Medicine Society 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5721915/
https://www.ncbi.nlm.nih.gov/pubmed/29264276
http://dx.doi.org/10.1016/j.asmart.2017.02.001
_version_ 1783284912913121280
author An, Vincent V.G.
Scholes, Corey
Mhaskar, Vikram A.
Parker, David A.
Fritsch, Brett A.
author_facet An, Vincent V.G.
Scholes, Corey
Mhaskar, Vikram A.
Parker, David A.
Fritsch, Brett A.
author_sort An, Vincent V.G.
collection PubMed
description BACKGROUND: Previous studies have associated anthropometric data and pre-operative hamstring tendon measurements to intraoperative graft diameter for hamstring autograft ACL reconstruction, although an integrated model has yet to be described. The aim of this study was to present such a predictive model for quadrupled semitendinosus (4-ST) and doubled semitendinosus-gracilis (4-STG) graft constructs combining anthropometry (height and weight) and preoperative measurements of tendon as predictors. METHODS: ACL reconstructions using 4-STG and 4-ST were retrospectively reviewed. The outlines of the semitendinosus and gracilis tendons were identified manually in the axial slice of a preoperative T2 weighted MRI using a region-of-interest tool. Regression analysis using intraoperative graft diameter as the dependent variable was performed with tendon cross-sectional area (XSA), gender and height as predictors. RESULTS: 108 ACL reconstructions in 107 patients were examined, 75 of which were performed using the 4-STG construct, and 33 which employed the 4-ST construct. The mean graft diameter in the 4-ST group (8.6 ± 0.8 mm) was significantly (p < 0.001) greater than the 4-STG group (7.9 ± 0.7 mm). Female gender and 4-STG graft construct were associated with increased risk of graft diameter <8 mm. Predictive models of graft diameter were accurate to ±1 mm for both construct types. CONCLUSIONS: An integrated method for assessing patient risk of producing a diminutive graft diameter and planning augmentation in select cases has been presented. The present findings describe a validated predictive model that builds on previous univariable analyses. Further investigation of larger samples, including factors associated with graft preparation, is required to improve model accuracy for routine clinical application. LEVEL OF EVIDENCE: IV, Retrospective Cohort Study
format Online
Article
Text
id pubmed-5721915
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Asia-Pacific Knee, Arthroscopy and Sports Medicine Society
record_format MEDLINE/PubMed
spelling pubmed-57219152017-12-20 Regression modelling combining MRI measurements and patient anthropometry for patient screening and prediction of graft diameter in hamstring autograft arthroscopic ACL reconstruction An, Vincent V.G. Scholes, Corey Mhaskar, Vikram A. Parker, David A. Fritsch, Brett A. Asia Pac J Sports Med Arthrosc Rehabil Technol Original Article BACKGROUND: Previous studies have associated anthropometric data and pre-operative hamstring tendon measurements to intraoperative graft diameter for hamstring autograft ACL reconstruction, although an integrated model has yet to be described. The aim of this study was to present such a predictive model for quadrupled semitendinosus (4-ST) and doubled semitendinosus-gracilis (4-STG) graft constructs combining anthropometry (height and weight) and preoperative measurements of tendon as predictors. METHODS: ACL reconstructions using 4-STG and 4-ST were retrospectively reviewed. The outlines of the semitendinosus and gracilis tendons were identified manually in the axial slice of a preoperative T2 weighted MRI using a region-of-interest tool. Regression analysis using intraoperative graft diameter as the dependent variable was performed with tendon cross-sectional area (XSA), gender and height as predictors. RESULTS: 108 ACL reconstructions in 107 patients were examined, 75 of which were performed using the 4-STG construct, and 33 which employed the 4-ST construct. The mean graft diameter in the 4-ST group (8.6 ± 0.8 mm) was significantly (p < 0.001) greater than the 4-STG group (7.9 ± 0.7 mm). Female gender and 4-STG graft construct were associated with increased risk of graft diameter <8 mm. Predictive models of graft diameter were accurate to ±1 mm for both construct types. CONCLUSIONS: An integrated method for assessing patient risk of producing a diminutive graft diameter and planning augmentation in select cases has been presented. The present findings describe a validated predictive model that builds on previous univariable analyses. Further investigation of larger samples, including factors associated with graft preparation, is required to improve model accuracy for routine clinical application. LEVEL OF EVIDENCE: IV, Retrospective Cohort Study Asia-Pacific Knee, Arthroscopy and Sports Medicine Society 2017-02-27 /pmc/articles/PMC5721915/ /pubmed/29264276 http://dx.doi.org/10.1016/j.asmart.2017.02.001 Text en © 2017 Asia Pacific Knee, Arthroscopy and Sports Medicine Society. Published by Elsevier (Singapore) Pte Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
An, Vincent V.G.
Scholes, Corey
Mhaskar, Vikram A.
Parker, David A.
Fritsch, Brett A.
Regression modelling combining MRI measurements and patient anthropometry for patient screening and prediction of graft diameter in hamstring autograft arthroscopic ACL reconstruction
title Regression modelling combining MRI measurements and patient anthropometry for patient screening and prediction of graft diameter in hamstring autograft arthroscopic ACL reconstruction
title_full Regression modelling combining MRI measurements and patient anthropometry for patient screening and prediction of graft diameter in hamstring autograft arthroscopic ACL reconstruction
title_fullStr Regression modelling combining MRI measurements and patient anthropometry for patient screening and prediction of graft diameter in hamstring autograft arthroscopic ACL reconstruction
title_full_unstemmed Regression modelling combining MRI measurements and patient anthropometry for patient screening and prediction of graft diameter in hamstring autograft arthroscopic ACL reconstruction
title_short Regression modelling combining MRI measurements and patient anthropometry for patient screening and prediction of graft diameter in hamstring autograft arthroscopic ACL reconstruction
title_sort regression modelling combining mri measurements and patient anthropometry for patient screening and prediction of graft diameter in hamstring autograft arthroscopic acl reconstruction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5721915/
https://www.ncbi.nlm.nih.gov/pubmed/29264276
http://dx.doi.org/10.1016/j.asmart.2017.02.001
work_keys_str_mv AT anvincentvg regressionmodellingcombiningmrimeasurementsandpatientanthropometryforpatientscreeningandpredictionofgraftdiameterinhamstringautograftarthroscopicaclreconstruction
AT scholescorey regressionmodellingcombiningmrimeasurementsandpatientanthropometryforpatientscreeningandpredictionofgraftdiameterinhamstringautograftarthroscopicaclreconstruction
AT mhaskarvikrama regressionmodellingcombiningmrimeasurementsandpatientanthropometryforpatientscreeningandpredictionofgraftdiameterinhamstringautograftarthroscopicaclreconstruction
AT parkerdavida regressionmodellingcombiningmrimeasurementsandpatientanthropometryforpatientscreeningandpredictionofgraftdiameterinhamstringautograftarthroscopicaclreconstruction
AT fritschbretta regressionmodellingcombiningmrimeasurementsandpatientanthropometryforpatientscreeningandpredictionofgraftdiameterinhamstringautograftarthroscopicaclreconstruction