Cargando…

Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography

BACKGROUND: We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). METHODS: The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 year...

Descripción completa

Detalles Bibliográficos
Autores principales: Koyoshi, Rie, Shiga, Yuhei, Idemoto, Yoshiaki, Ueda, Yoko, Tashiro, Kohei, Kuwano, Takashi, Kitajima, Ken, Fujimi, Kanta, Kawamura, Akira, Ogawa, Masahiro, Miura, Shin-ichiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elmer Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722041/
https://www.ncbi.nlm.nih.gov/pubmed/29238430
http://dx.doi.org/10.14740/jocmr3213w
_version_ 1783284932149248000
author Koyoshi, Rie
Shiga, Yuhei
Idemoto, Yoshiaki
Ueda, Yoko
Tashiro, Kohei
Kuwano, Takashi
Kitajima, Ken
Fujimi, Kanta
Kawamura, Akira
Ogawa, Masahiro
Miura, Shin-ichiro
author_facet Koyoshi, Rie
Shiga, Yuhei
Idemoto, Yoshiaki
Ueda, Yoko
Tashiro, Kohei
Kuwano, Takashi
Kitajima, Ken
Fujimi, Kanta
Kawamura, Akira
Ogawa, Masahiro
Miura, Shin-ichiro
author_sort Koyoshi, Rie
collection PubMed
description BACKGROUND: We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). METHODS: The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. RESULTS: SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. CONCLUSION: In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.
format Online
Article
Text
id pubmed-5722041
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elmer Press
record_format MEDLINE/PubMed
spelling pubmed-57220412017-12-13 Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography Koyoshi, Rie Shiga, Yuhei Idemoto, Yoshiaki Ueda, Yoko Tashiro, Kohei Kuwano, Takashi Kitajima, Ken Fujimi, Kanta Kawamura, Akira Ogawa, Masahiro Miura, Shin-ichiro J Clin Med Res Original Article BACKGROUND: We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). METHODS: The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. RESULTS: SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. CONCLUSION: In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA. Elmer Press 2018-01 2017-12-01 /pmc/articles/PMC5722041/ /pubmed/29238430 http://dx.doi.org/10.14740/jocmr3213w Text en Copyright 2018, Koyoshi et al. http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Koyoshi, Rie
Shiga, Yuhei
Idemoto, Yoshiaki
Ueda, Yoko
Tashiro, Kohei
Kuwano, Takashi
Kitajima, Ken
Fujimi, Kanta
Kawamura, Akira
Ogawa, Masahiro
Miura, Shin-ichiro
Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography
title Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography
title_full Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography
title_fullStr Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography
title_full_unstemmed Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography
title_short Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography
title_sort safety of landiolol hydrochloride as a premedication for producing an appropriate heart rate for multidetector-row computed tomography coronary angiography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722041/
https://www.ncbi.nlm.nih.gov/pubmed/29238430
http://dx.doi.org/10.14740/jocmr3213w
work_keys_str_mv AT koyoshirie safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT shigayuhei safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT idemotoyoshiaki safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT uedayoko safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT tashirokohei safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT kuwanotakashi safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT kitajimaken safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT fujimikanta safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT kawamuraakira safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT ogawamasahiro safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography
AT miurashinichiro safetyoflandiololhydrochlorideasapremedicationforproducinganappropriateheartrateformultidetectorrowcomputedtomographycoronaryangiography