Cargando…

Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro

INTRODUCTION: Endodontic instruments are developed to provide a better cleaning of the root canal system and reduce its risk of fracture. The aim of this study was to evaluate the instrumentation time and cyclic fatigue resistance of WaveOne Gold, ProDesign R and ProDesign Logic files. METHODS AND M...

Descripción completa

Detalles Bibliográficos
Autores principales: de Menezes, Sílvio Emanuel Acioly Conrado, Batista, Shirley Machado, Lira, Juliana Ouro Preto, de Melo Monteiro, Gabriela Queiroz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iranian Center for Endodontic Research 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722121/
https://www.ncbi.nlm.nih.gov/pubmed/29225643
http://dx.doi.org/10.22037/iej.v12i4.17494
_version_ 1783284953686999040
author de Menezes, Sílvio Emanuel Acioly Conrado
Batista, Shirley Machado
Lira, Juliana Ouro Preto
de Melo Monteiro, Gabriela Queiroz
author_facet de Menezes, Sílvio Emanuel Acioly Conrado
Batista, Shirley Machado
Lira, Juliana Ouro Preto
de Melo Monteiro, Gabriela Queiroz
author_sort de Menezes, Sílvio Emanuel Acioly Conrado
collection PubMed
description INTRODUCTION: Endodontic instruments are developed to provide a better cleaning of the root canal system and reduce its risk of fracture. The aim of this study was to evaluate the instrumentation time and cyclic fatigue resistance of WaveOne Gold, ProDesign R and ProDesign Logic files. METHODS AND MATERIALS: Thirty Nickel-titanium (NiTi) rotary instruments were divided into 3 groups (n=10). ProDesign Logic file 25/0.06 was used in continuous rotation after glide path preparation. WaveOne Gold 25/0.07 and ProDesign R 25/0.06 files were used in reciprocating motion. Every file instrumented 3 standardized artificial canals. The average time, the number of cycles (NCI) and cyclic fatigue resistance of each file were determined through the number of cycles to failure (NCF) in a stainless-steel device. The total amount of cycles to fracture was also calculated (NCI+NCF). Data was analyzed using the Kruskal-Wallis and Mann-Whitney tests. RESULTS: The instrumentation time of the ProDesign Logic file was significantly lower when compared to the other files (P=0.019). The longest times to failure were presented by ProDesign Logic (182.07 sec) and ProDesign R (152.38 sec) files. The same differences were observed for the NCF (910.37 and 761.93). The WaveOne Gold group presented a lower NCF as well as a smaller sum of NCI+NCF (748.33) that was statistically significant when compared to the other groups (P<0.05) respectively. CONCLUSION: The use of continuous rotational motion in canals with a glide path in the ProDesign Logic group led to shorter instrumentation time. The cyclic fatigue resistance of ProDesign R and Logic instruments was superior to WaveOne Gold. The thermal treatment of the instrument’s alloy, its cross section and the glide path seems to influence the cyclic fatigue resistance.
format Online
Article
Text
id pubmed-5722121
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Iranian Center for Endodontic Research
record_format MEDLINE/PubMed
spelling pubmed-57221212017-12-08 Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro de Menezes, Sílvio Emanuel Acioly Conrado Batista, Shirley Machado Lira, Juliana Ouro Preto de Melo Monteiro, Gabriela Queiroz Iran Endod J Original Article INTRODUCTION: Endodontic instruments are developed to provide a better cleaning of the root canal system and reduce its risk of fracture. The aim of this study was to evaluate the instrumentation time and cyclic fatigue resistance of WaveOne Gold, ProDesign R and ProDesign Logic files. METHODS AND MATERIALS: Thirty Nickel-titanium (NiTi) rotary instruments were divided into 3 groups (n=10). ProDesign Logic file 25/0.06 was used in continuous rotation after glide path preparation. WaveOne Gold 25/0.07 and ProDesign R 25/0.06 files were used in reciprocating motion. Every file instrumented 3 standardized artificial canals. The average time, the number of cycles (NCI) and cyclic fatigue resistance of each file were determined through the number of cycles to failure (NCF) in a stainless-steel device. The total amount of cycles to fracture was also calculated (NCI+NCF). Data was analyzed using the Kruskal-Wallis and Mann-Whitney tests. RESULTS: The instrumentation time of the ProDesign Logic file was significantly lower when compared to the other files (P=0.019). The longest times to failure were presented by ProDesign Logic (182.07 sec) and ProDesign R (152.38 sec) files. The same differences were observed for the NCF (910.37 and 761.93). The WaveOne Gold group presented a lower NCF as well as a smaller sum of NCI+NCF (748.33) that was statistically significant when compared to the other groups (P<0.05) respectively. CONCLUSION: The use of continuous rotational motion in canals with a glide path in the ProDesign Logic group led to shorter instrumentation time. The cyclic fatigue resistance of ProDesign R and Logic instruments was superior to WaveOne Gold. The thermal treatment of the instrument’s alloy, its cross section and the glide path seems to influence the cyclic fatigue resistance. Iranian Center for Endodontic Research 2017 /pmc/articles/PMC5722121/ /pubmed/29225643 http://dx.doi.org/10.22037/iej.v12i4.17494 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
de Menezes, Sílvio Emanuel Acioly Conrado
Batista, Shirley Machado
Lira, Juliana Ouro Preto
de Melo Monteiro, Gabriela Queiroz
Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro
title Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro
title_full Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro
title_fullStr Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro
title_full_unstemmed Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro
title_short Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro
title_sort cyclic fatigue resistance of waveone gold, prodesign r and prodesign logic files in curved canals in vitro
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722121/
https://www.ncbi.nlm.nih.gov/pubmed/29225643
http://dx.doi.org/10.22037/iej.v12i4.17494
work_keys_str_mv AT demenezessilvioemanuelaciolyconrado cyclicfatigueresistanceofwaveonegoldprodesignrandprodesignlogicfilesincurvedcanalsinvitro
AT batistashirleymachado cyclicfatigueresistanceofwaveonegoldprodesignrandprodesignlogicfilesincurvedcanalsinvitro
AT lirajulianaouropreto cyclicfatigueresistanceofwaveonegoldprodesignrandprodesignlogicfilesincurvedcanalsinvitro
AT demelomonteirogabrielaqueiroz cyclicfatigueresistanceofwaveonegoldprodesignrandprodesignlogicfilesincurvedcanalsinvitro