Cargando…

Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy

We present a simple and fast high-performance liquid chromatography method with fluorescence detection for the determination of the antiepileptic drug perampanel in human plasma. The chromatographic separation was performed on a Kinetex PFP (100 × 2.6 mm, 4.6 µm) column, using a mobile phase of sodi...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohamed, Susan, Candela, Carmina, Riva, Roberto, Contin, Manuela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722279/
https://www.ncbi.nlm.nih.gov/pubmed/29234708
http://dx.doi.org/10.1016/j.plabm.2017.11.003
_version_ 1783284975687172096
author Mohamed, Susan
Candela, Carmina
Riva, Roberto
Contin, Manuela
author_facet Mohamed, Susan
Candela, Carmina
Riva, Roberto
Contin, Manuela
author_sort Mohamed, Susan
collection PubMed
description We present a simple and fast high-performance liquid chromatography method with fluorescence detection for the determination of the antiepileptic drug perampanel in human plasma. The chromatographic separation was performed on a Kinetex PFP (100 × 2.6 mm, 4.6 µm) column, using a mobile phase of sodium acetate 0.03 M pH 3.7 and acetonitrile (40/60, v/v), at a flow rate of 0.8 mL/min. Total chromatography time for each run was 5 min. Sample preparation (250 µL) involved only one simple precipitation step by acetonitrile spiked with mirtazapine as internal standard. The method was validated over a concentration range of 20–1000 ng/mL and successfully applied to measure perampanel concentrations in plasma samples obtained from patients with epilepsy. This assay combines the high specificity of fluorescence detection with a very simple and fast sample pretreatment and can offer real advantages over existing methods in terms of simplicity and transferability to a therapeutic drug monitoring setting.
format Online
Article
Text
id pubmed-5722279
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-57222792017-12-11 Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy Mohamed, Susan Candela, Carmina Riva, Roberto Contin, Manuela Pract Lab Med Article We present a simple and fast high-performance liquid chromatography method with fluorescence detection for the determination of the antiepileptic drug perampanel in human plasma. The chromatographic separation was performed on a Kinetex PFP (100 × 2.6 mm, 4.6 µm) column, using a mobile phase of sodium acetate 0.03 M pH 3.7 and acetonitrile (40/60, v/v), at a flow rate of 0.8 mL/min. Total chromatography time for each run was 5 min. Sample preparation (250 µL) involved only one simple precipitation step by acetonitrile spiked with mirtazapine as internal standard. The method was validated over a concentration range of 20–1000 ng/mL and successfully applied to measure perampanel concentrations in plasma samples obtained from patients with epilepsy. This assay combines the high specificity of fluorescence detection with a very simple and fast sample pretreatment and can offer real advantages over existing methods in terms of simplicity and transferability to a therapeutic drug monitoring setting. Elsevier 2017-11-26 /pmc/articles/PMC5722279/ /pubmed/29234708 http://dx.doi.org/10.1016/j.plabm.2017.11.003 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Mohamed, Susan
Candela, Carmina
Riva, Roberto
Contin, Manuela
Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy
title Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy
title_full Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy
title_fullStr Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy
title_full_unstemmed Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy
title_short Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy
title_sort simple and rapid validated hplc-fluorescence determination of perampanel in the plasma of patients with epilepsy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722279/
https://www.ncbi.nlm.nih.gov/pubmed/29234708
http://dx.doi.org/10.1016/j.plabm.2017.11.003
work_keys_str_mv AT mohamedsusan simpleandrapidvalidatedhplcfluorescencedeterminationofperampanelintheplasmaofpatientswithepilepsy
AT candelacarmina simpleandrapidvalidatedhplcfluorescencedeterminationofperampanelintheplasmaofpatientswithepilepsy
AT rivaroberto simpleandrapidvalidatedhplcfluorescencedeterminationofperampanelintheplasmaofpatientswithepilepsy
AT continmanuela simpleandrapidvalidatedhplcfluorescencedeterminationofperampanelintheplasmaofpatientswithepilepsy