Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy
We present a simple and fast high-performance liquid chromatography method with fluorescence detection for the determination of the antiepileptic drug perampanel in human plasma. The chromatographic separation was performed on a Kinetex PFP (100 × 2.6 mm, 4.6 µm) column, using a mobile phase of sodi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722279/ https://www.ncbi.nlm.nih.gov/pubmed/29234708 http://dx.doi.org/10.1016/j.plabm.2017.11.003 |
_version_ | 1783284975687172096 |
---|---|
author | Mohamed, Susan Candela, Carmina Riva, Roberto Contin, Manuela |
author_facet | Mohamed, Susan Candela, Carmina Riva, Roberto Contin, Manuela |
author_sort | Mohamed, Susan |
collection | PubMed |
description | We present a simple and fast high-performance liquid chromatography method with fluorescence detection for the determination of the antiepileptic drug perampanel in human plasma. The chromatographic separation was performed on a Kinetex PFP (100 × 2.6 mm, 4.6 µm) column, using a mobile phase of sodium acetate 0.03 M pH 3.7 and acetonitrile (40/60, v/v), at a flow rate of 0.8 mL/min. Total chromatography time for each run was 5 min. Sample preparation (250 µL) involved only one simple precipitation step by acetonitrile spiked with mirtazapine as internal standard. The method was validated over a concentration range of 20–1000 ng/mL and successfully applied to measure perampanel concentrations in plasma samples obtained from patients with epilepsy. This assay combines the high specificity of fluorescence detection with a very simple and fast sample pretreatment and can offer real advantages over existing methods in terms of simplicity and transferability to a therapeutic drug monitoring setting. |
format | Online Article Text |
id | pubmed-5722279 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-57222792017-12-11 Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy Mohamed, Susan Candela, Carmina Riva, Roberto Contin, Manuela Pract Lab Med Article We present a simple and fast high-performance liquid chromatography method with fluorescence detection for the determination of the antiepileptic drug perampanel in human plasma. The chromatographic separation was performed on a Kinetex PFP (100 × 2.6 mm, 4.6 µm) column, using a mobile phase of sodium acetate 0.03 M pH 3.7 and acetonitrile (40/60, v/v), at a flow rate of 0.8 mL/min. Total chromatography time for each run was 5 min. Sample preparation (250 µL) involved only one simple precipitation step by acetonitrile spiked with mirtazapine as internal standard. The method was validated over a concentration range of 20–1000 ng/mL and successfully applied to measure perampanel concentrations in plasma samples obtained from patients with epilepsy. This assay combines the high specificity of fluorescence detection with a very simple and fast sample pretreatment and can offer real advantages over existing methods in terms of simplicity and transferability to a therapeutic drug monitoring setting. Elsevier 2017-11-26 /pmc/articles/PMC5722279/ /pubmed/29234708 http://dx.doi.org/10.1016/j.plabm.2017.11.003 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Mohamed, Susan Candela, Carmina Riva, Roberto Contin, Manuela Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy |
title | Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy |
title_full | Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy |
title_fullStr | Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy |
title_full_unstemmed | Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy |
title_short | Simple and rapid validated HPLC-fluorescence determination of perampanel in the plasma of patients with epilepsy |
title_sort | simple and rapid validated hplc-fluorescence determination of perampanel in the plasma of patients with epilepsy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722279/ https://www.ncbi.nlm.nih.gov/pubmed/29234708 http://dx.doi.org/10.1016/j.plabm.2017.11.003 |
work_keys_str_mv | AT mohamedsusan simpleandrapidvalidatedhplcfluorescencedeterminationofperampanelintheplasmaofpatientswithepilepsy AT candelacarmina simpleandrapidvalidatedhplcfluorescencedeterminationofperampanelintheplasmaofpatientswithepilepsy AT rivaroberto simpleandrapidvalidatedhplcfluorescencedeterminationofperampanelintheplasmaofpatientswithepilepsy AT continmanuela simpleandrapidvalidatedhplcfluorescencedeterminationofperampanelintheplasmaofpatientswithepilepsy |