Cargando…

Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film

Micro‐multileaf collimator systems coupled to linear accelerators for radioneurosurgery treatments require a rigorous dosimetric characterization in order to be used in 3D conformal and intensity modulated stereotactic radiosurgery and radiotherapy applications. This characterization involves high p...

Descripción completa

Detalles Bibliográficos
Autores principales: García‐Garduño, Olivia Amanda, Celis, Miguel Ángel, Lárraga‐Gutiérrez, José Manuel, Moreno‐Jiménez, Sergio, Martínez‐Dávalos, Arnulfo, Rodríguez‐Villafuerte, Mercedes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722293/
https://www.ncbi.nlm.nih.gov/pubmed/18716595
http://dx.doi.org/10.1120/jacmp.v9i3.2802
_version_ 1783284979070926848
author García‐Garduño, Olivia Amanda
Celis, Miguel Ángel
Lárraga‐Gutiérrez, José Manuel
Moreno‐Jiménez, Sergio
Martínez‐Dávalos, Arnulfo
Rodríguez‐Villafuerte, Mercedes
author_facet García‐Garduño, Olivia Amanda
Celis, Miguel Ángel
Lárraga‐Gutiérrez, José Manuel
Moreno‐Jiménez, Sergio
Martínez‐Dávalos, Arnulfo
Rodríguez‐Villafuerte, Mercedes
author_sort García‐Garduño, Olivia Amanda
collection PubMed
description Micro‐multileaf collimator systems coupled to linear accelerators for radioneurosurgery treatments require a rigorous dosimetric characterization in order to be used in 3D conformal and intensity modulated stereotactic radiosurgery and radiotherapy applications. This characterization involves high precision measurements of leaf transmission, leakage and beam penumbra through the collimation system and requires the use of detectors with high spatial resolution, high sensitivity and practically no energy dependence. In this work the use of GafChromic EBT radiochromic film to measure the basic dosimetric properties of the m3‐mMLC (BrainLAB, Germany) micro‐multileaf collimator system integrated to a 6 MV linear accelerator, is reported. Results show that average values of transmission and leakage radiation are [Formula: see text] and [Formula: see text] , respectively. The 80–20% beam penumbra were found to be [Formula: see text] along the leaf side (perpendicular to leaf motion) and [Formula: see text] along the leaf end (parallel to leaf motion) using square field sizes ranging from 9.1 to 1.8 cm. These measurements are in agreement with values reported in the literature for the same type of mMLC using different radiation detectors. PACS number: 87.56.N‐
format Online
Article
Text
id pubmed-5722293
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57222932018-04-02 Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film García‐Garduño, Olivia Amanda Celis, Miguel Ángel Lárraga‐Gutiérrez, José Manuel Moreno‐Jiménez, Sergio Martínez‐Dávalos, Arnulfo Rodríguez‐Villafuerte, Mercedes J Appl Clin Med Phys Radiation Oncology Physics Micro‐multileaf collimator systems coupled to linear accelerators for radioneurosurgery treatments require a rigorous dosimetric characterization in order to be used in 3D conformal and intensity modulated stereotactic radiosurgery and radiotherapy applications. This characterization involves high precision measurements of leaf transmission, leakage and beam penumbra through the collimation system and requires the use of detectors with high spatial resolution, high sensitivity and practically no energy dependence. In this work the use of GafChromic EBT radiochromic film to measure the basic dosimetric properties of the m3‐mMLC (BrainLAB, Germany) micro‐multileaf collimator system integrated to a 6 MV linear accelerator, is reported. Results show that average values of transmission and leakage radiation are [Formula: see text] and [Formula: see text] , respectively. The 80–20% beam penumbra were found to be [Formula: see text] along the leaf side (perpendicular to leaf motion) and [Formula: see text] along the leaf end (parallel to leaf motion) using square field sizes ranging from 9.1 to 1.8 cm. These measurements are in agreement with values reported in the literature for the same type of mMLC using different radiation detectors. PACS number: 87.56.N‐ John Wiley and Sons Inc. 2008-06-23 /pmc/articles/PMC5722293/ /pubmed/18716595 http://dx.doi.org/10.1120/jacmp.v9i3.2802 Text en © 2008 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
García‐Garduño, Olivia Amanda
Celis, Miguel Ángel
Lárraga‐Gutiérrez, José Manuel
Moreno‐Jiménez, Sergio
Martínez‐Dávalos, Arnulfo
Rodríguez‐Villafuerte, Mercedes
Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film
title Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film
title_full Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film
title_fullStr Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film
title_full_unstemmed Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film
title_short Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film
title_sort radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using gafchromic ebt film
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722293/
https://www.ncbi.nlm.nih.gov/pubmed/18716595
http://dx.doi.org/10.1120/jacmp.v9i3.2802
work_keys_str_mv AT garciagardunooliviaamanda radiationtransmissionleakageandbeampenumbrameasurementsofamicromultileafcollimatorusinggafchromicebtfilm
AT celismiguelangel radiationtransmissionleakageandbeampenumbrameasurementsofamicromultileafcollimatorusinggafchromicebtfilm
AT larragagutierrezjosemanuel radiationtransmissionleakageandbeampenumbrameasurementsofamicromultileafcollimatorusinggafchromicebtfilm
AT morenojimenezsergio radiationtransmissionleakageandbeampenumbrameasurementsofamicromultileafcollimatorusinggafchromicebtfilm
AT martinezdavalosarnulfo radiationtransmissionleakageandbeampenumbrameasurementsofamicromultileafcollimatorusinggafchromicebtfilm
AT rodriguezvillafuertemercedes radiationtransmissionleakageandbeampenumbrameasurementsofamicromultileafcollimatorusinggafchromicebtfilm