Cargando…

Optimized plasma preparation is essential to monitor platelet-stored molecules in humans

Platelets store a plethora of different molecules within their granules, modulating numerous pathways, not only in coagulation, but also in angiogenesis, wound healing, and inflammatory diseases. These molecules get rapidly released upon activation and therefore represent an easily accessible indire...

Descripción completa

Detalles Bibliográficos
Autores principales: Mussbacher, Marion, Schrottmaier, Waltraud C., Salzmann, Manuel, Brostjan, Christine, Schmid, Johannes A., Starlinger, Patrick, Assinger, Alice
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722331/
https://www.ncbi.nlm.nih.gov/pubmed/29220362
http://dx.doi.org/10.1371/journal.pone.0188921
_version_ 1783284988428419072
author Mussbacher, Marion
Schrottmaier, Waltraud C.
Salzmann, Manuel
Brostjan, Christine
Schmid, Johannes A.
Starlinger, Patrick
Assinger, Alice
author_facet Mussbacher, Marion
Schrottmaier, Waltraud C.
Salzmann, Manuel
Brostjan, Christine
Schmid, Johannes A.
Starlinger, Patrick
Assinger, Alice
author_sort Mussbacher, Marion
collection PubMed
description Platelets store a plethora of different molecules within their granules, modulating numerous pathways, not only in coagulation, but also in angiogenesis, wound healing, and inflammatory diseases. These molecules get rapidly released upon activation and therefore represent an easily accessible indirect marker for platelet activation. Accurate analysis of platelet-derived molecules in the plasma requires appropriate anticoagulation to avoid in vitro activation and subsequent degranulation of platelets, potentially causing artificially high levels and masking biologically relevant differences within translational research studies. However, there is still enormous heterogeneity among anticoagulants used to prevent unwanted platelet activation, so that plasma levels reported for platelet granule contents range over several orders of magnitude. To address this problem and to define the most robust method of plasma preparation to avoid in vitro platelet activation during processing, we compared plasma concentrations of the three platelet-stored factors thrombospondin (TSP-1), platelet factor 4 (PF4), and soluble P-selectin (sCD62P) between human blood samples anticoagulated with either citrate-theophylline-adenosine-dipyridamole (CTAD), acid-citrate-dextrose (ACD), citrate, ethylenediaminetetraacetic acid (EDTA) or heparin. Additionally, we assessed the effect of storage temperature and time between blood drawing and sample processing within the differentially anticoagulated samples. Our data strongly support the use of CTAD as anticoagulant for determining plasma concentrations of platelet-stored molecules, as anticoagulation with heparin or EDTA led to a 12.4- or 8.3-fold increase in plasma levels of PF4, respectively. Whereas ACD was similar effective as CTAD, citrate only showed comparable PF4 plasma levels when plasma was kept at 4°C. Moreover, blood sampling with CTAD as anticoagulant resulted in the most reproducible values, even when samples were processed at ambient temperature or after storage over 6 hours. In the latter case, anticoagulation with heparin or EDTA led to artificially high plasma levels indicative of in vitro platelet activation. Therefore, we want to raise scientific awareness for choosing CTAD as optimal anticoagulant for the detection of platelet-stored molecules in plasma.
format Online
Article
Text
id pubmed-5722331
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-57223312017-12-15 Optimized plasma preparation is essential to monitor platelet-stored molecules in humans Mussbacher, Marion Schrottmaier, Waltraud C. Salzmann, Manuel Brostjan, Christine Schmid, Johannes A. Starlinger, Patrick Assinger, Alice PLoS One Research Article Platelets store a plethora of different molecules within their granules, modulating numerous pathways, not only in coagulation, but also in angiogenesis, wound healing, and inflammatory diseases. These molecules get rapidly released upon activation and therefore represent an easily accessible indirect marker for platelet activation. Accurate analysis of platelet-derived molecules in the plasma requires appropriate anticoagulation to avoid in vitro activation and subsequent degranulation of platelets, potentially causing artificially high levels and masking biologically relevant differences within translational research studies. However, there is still enormous heterogeneity among anticoagulants used to prevent unwanted platelet activation, so that plasma levels reported for platelet granule contents range over several orders of magnitude. To address this problem and to define the most robust method of plasma preparation to avoid in vitro platelet activation during processing, we compared plasma concentrations of the three platelet-stored factors thrombospondin (TSP-1), platelet factor 4 (PF4), and soluble P-selectin (sCD62P) between human blood samples anticoagulated with either citrate-theophylline-adenosine-dipyridamole (CTAD), acid-citrate-dextrose (ACD), citrate, ethylenediaminetetraacetic acid (EDTA) or heparin. Additionally, we assessed the effect of storage temperature and time between blood drawing and sample processing within the differentially anticoagulated samples. Our data strongly support the use of CTAD as anticoagulant for determining plasma concentrations of platelet-stored molecules, as anticoagulation with heparin or EDTA led to a 12.4- or 8.3-fold increase in plasma levels of PF4, respectively. Whereas ACD was similar effective as CTAD, citrate only showed comparable PF4 plasma levels when plasma was kept at 4°C. Moreover, blood sampling with CTAD as anticoagulant resulted in the most reproducible values, even when samples were processed at ambient temperature or after storage over 6 hours. In the latter case, anticoagulation with heparin or EDTA led to artificially high plasma levels indicative of in vitro platelet activation. Therefore, we want to raise scientific awareness for choosing CTAD as optimal anticoagulant for the detection of platelet-stored molecules in plasma. Public Library of Science 2017-12-08 /pmc/articles/PMC5722331/ /pubmed/29220362 http://dx.doi.org/10.1371/journal.pone.0188921 Text en © 2017 Mussbacher et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Mussbacher, Marion
Schrottmaier, Waltraud C.
Salzmann, Manuel
Brostjan, Christine
Schmid, Johannes A.
Starlinger, Patrick
Assinger, Alice
Optimized plasma preparation is essential to monitor platelet-stored molecules in humans
title Optimized plasma preparation is essential to monitor platelet-stored molecules in humans
title_full Optimized plasma preparation is essential to monitor platelet-stored molecules in humans
title_fullStr Optimized plasma preparation is essential to monitor platelet-stored molecules in humans
title_full_unstemmed Optimized plasma preparation is essential to monitor platelet-stored molecules in humans
title_short Optimized plasma preparation is essential to monitor platelet-stored molecules in humans
title_sort optimized plasma preparation is essential to monitor platelet-stored molecules in humans
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722331/
https://www.ncbi.nlm.nih.gov/pubmed/29220362
http://dx.doi.org/10.1371/journal.pone.0188921
work_keys_str_mv AT mussbachermarion optimizedplasmapreparationisessentialtomonitorplateletstoredmoleculesinhumans
AT schrottmaierwaltraudc optimizedplasmapreparationisessentialtomonitorplateletstoredmoleculesinhumans
AT salzmannmanuel optimizedplasmapreparationisessentialtomonitorplateletstoredmoleculesinhumans
AT brostjanchristine optimizedplasmapreparationisessentialtomonitorplateletstoredmoleculesinhumans
AT schmidjohannesa optimizedplasmapreparationisessentialtomonitorplateletstoredmoleculesinhumans
AT starlingerpatrick optimizedplasmapreparationisessentialtomonitorplateletstoredmoleculesinhumans
AT assingeralice optimizedplasmapreparationisessentialtomonitorplateletstoredmoleculesinhumans