Verifying monitor unit calculations for tangential breast fields

An essential component of quality assurance in radiation therapy is verifying the accuracy of monitor unit calculations. Differences between sophisticated algorithms using 2.5D or 3D calculations and simpler monitor unit check algorithms or hand calculations assuming a flat water phantom must be exp...

Descripción completa

Detalles Bibliográficos
Autores principales: Kay, Ian, Dunscombe, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722436/
https://www.ncbi.nlm.nih.gov/pubmed/17533323
http://dx.doi.org/10.1120/jacmp.v7i2.2177
_version_ 1783285014014722048
author Kay, Ian
Dunscombe, Peter
author_facet Kay, Ian
Dunscombe, Peter
author_sort Kay, Ian
collection PubMed
description An essential component of quality assurance in radiation therapy is verifying the accuracy of monitor unit calculations. Differences between sophisticated algorithms using 2.5D or 3D calculations and simpler monitor unit check algorithms or hand calculations assuming a flat water phantom must be expected. For many anatomical sites, such differences are small and of little or no consequence in the context of expected clinical impact. However, for tangential breast fields the discrepancies are considerably larger than those that would generally be considered acceptable. A simple model to reconcile the differences between sophisticated and simple algorithms is presented, based on replacing the breast contour with a triangular or elliptical contour and using this to estimate an equivalent rectangular prism providing equivalent scatter to the prescription point. The elliptical approximation reconciles the observed differences in calculated monitor units. The analysis we present can assist the treatment planning physicist in selecting a method and tolerance window for verifying monitor unit calculations for tangential breast fields. PACS: 87.53.Kn, 87.53.Tf, 87.53.Xd
format Online
Article
Text
id pubmed-5722436
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57224362018-04-02 Verifying monitor unit calculations for tangential breast fields Kay, Ian Dunscombe, Peter J Appl Clin Med Phys Radiation Oncology Physics An essential component of quality assurance in radiation therapy is verifying the accuracy of monitor unit calculations. Differences between sophisticated algorithms using 2.5D or 3D calculations and simpler monitor unit check algorithms or hand calculations assuming a flat water phantom must be expected. For many anatomical sites, such differences are small and of little or no consequence in the context of expected clinical impact. However, for tangential breast fields the discrepancies are considerably larger than those that would generally be considered acceptable. A simple model to reconcile the differences between sophisticated and simple algorithms is presented, based on replacing the breast contour with a triangular or elliptical contour and using this to estimate an equivalent rectangular prism providing equivalent scatter to the prescription point. The elliptical approximation reconciles the observed differences in calculated monitor units. The analysis we present can assist the treatment planning physicist in selecting a method and tolerance window for verifying monitor unit calculations for tangential breast fields. PACS: 87.53.Kn, 87.53.Tf, 87.53.Xd John Wiley and Sons Inc. 2006-05-25 /pmc/articles/PMC5722436/ /pubmed/17533323 http://dx.doi.org/10.1120/jacmp.v7i2.2177 Text en © 2006 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Kay, Ian
Dunscombe, Peter
Verifying monitor unit calculations for tangential breast fields
title Verifying monitor unit calculations for tangential breast fields
title_full Verifying monitor unit calculations for tangential breast fields
title_fullStr Verifying monitor unit calculations for tangential breast fields
title_full_unstemmed Verifying monitor unit calculations for tangential breast fields
title_short Verifying monitor unit calculations for tangential breast fields
title_sort verifying monitor unit calculations for tangential breast fields
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722436/
https://www.ncbi.nlm.nih.gov/pubmed/17533323
http://dx.doi.org/10.1120/jacmp.v7i2.2177
work_keys_str_mv AT kayian verifyingmonitorunitcalculationsfortangentialbreastfields
AT dunscombepeter verifyingmonitorunitcalculationsfortangentialbreastfields