Experimental verification of the application of lateral buildup ratio on the 4‐MeV electron beam

The lateral buildup ratio (LBR) used to estimate the depth dose distribution of electron beams for an irregular cutout field was obtained for a 4‐MeV energy beam from a Varian 21 EX linear accelerator. The depth‐dose curves for a group of circular cutout fields starting from a 2‐cm diameter were mea...

Descripción completa

Detalles Bibliográficos
Autores principales: Chow, James C.L., Newman, Scott
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722474/
https://www.ncbi.nlm.nih.gov/pubmed/16518315
http://dx.doi.org/10.1120/jacmp.v7i1.2153
_version_ 1783285019219853312
author Chow, James C.L.
Newman, Scott
author_facet Chow, James C.L.
Newman, Scott
author_sort Chow, James C.L.
collection PubMed
description The lateral buildup ratio (LBR) used to estimate the depth dose distribution of electron beams for an irregular cutout field was obtained for a 4‐MeV energy beam from a Varian 21 EX linear accelerator. The depth‐dose curves for a group of circular cutout fields starting from a 2‐cm diameter were measured. Electron diodes were used in a large water tank to measure the LBR values for 6, 9, 12, and 16 MeV electron beam energies and a [Formula: see text] applicator. The results agreed with the published data. When the same equipment, setup, and technique were used to determine the LBR values for the 4‐MeV energy beam, the values were only reasonable, being within the clinical treatment range (i.e., LBR [Formula: see text]) for the smallest [Formula: see text] applicator. The calculated LBR values were clinically unacceptable for the circular cutout fields with a diameter larger than 2 cm with the [Formula: see text] applicator. The difficulty in the LBR measurement may be due to the significant contribution of scattered electrons from the beam defining system. This study also focused on how well the sigma values for the 4‐MeV beam can predict depth‐dose curves for other field sizes and whether the values are applicator‐dependent. PACS numbers: 87.53.Fs; 87.53.Hv; 87.66.Jj
format Online
Article
Text
id pubmed-5722474
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57224742018-04-02 Experimental verification of the application of lateral buildup ratio on the 4‐MeV electron beam Chow, James C.L. Newman, Scott J Appl Clin Med Phys Radiation Oncology Physics The lateral buildup ratio (LBR) used to estimate the depth dose distribution of electron beams for an irregular cutout field was obtained for a 4‐MeV energy beam from a Varian 21 EX linear accelerator. The depth‐dose curves for a group of circular cutout fields starting from a 2‐cm diameter were measured. Electron diodes were used in a large water tank to measure the LBR values for 6, 9, 12, and 16 MeV electron beam energies and a [Formula: see text] applicator. The results agreed with the published data. When the same equipment, setup, and technique were used to determine the LBR values for the 4‐MeV energy beam, the values were only reasonable, being within the clinical treatment range (i.e., LBR [Formula: see text]) for the smallest [Formula: see text] applicator. The calculated LBR values were clinically unacceptable for the circular cutout fields with a diameter larger than 2 cm with the [Formula: see text] applicator. The difficulty in the LBR measurement may be due to the significant contribution of scattered electrons from the beam defining system. This study also focused on how well the sigma values for the 4‐MeV beam can predict depth‐dose curves for other field sizes and whether the values are applicator‐dependent. PACS numbers: 87.53.Fs; 87.53.Hv; 87.66.Jj John Wiley and Sons Inc. 2006-02-21 /pmc/articles/PMC5722474/ /pubmed/16518315 http://dx.doi.org/10.1120/jacmp.v7i1.2153 Text en © 2006 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Chow, James C.L.
Newman, Scott
Experimental verification of the application of lateral buildup ratio on the 4‐MeV electron beam
title Experimental verification of the application of lateral buildup ratio on the 4‐MeV electron beam
title_full Experimental verification of the application of lateral buildup ratio on the 4‐MeV electron beam
title_fullStr Experimental verification of the application of lateral buildup ratio on the 4‐MeV electron beam
title_full_unstemmed Experimental verification of the application of lateral buildup ratio on the 4‐MeV electron beam
title_short Experimental verification of the application of lateral buildup ratio on the 4‐MeV electron beam
title_sort experimental verification of the application of lateral buildup ratio on the 4‐mev electron beam
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722474/
https://www.ncbi.nlm.nih.gov/pubmed/16518315
http://dx.doi.org/10.1120/jacmp.v7i1.2153
work_keys_str_mv AT chowjamescl experimentalverificationoftheapplicationoflateralbuildupratioonthe4mevelectronbeam
AT newmanscott experimentalverificationoftheapplicationoflateralbuildupratioonthe4mevelectronbeam