A survey on planar IMRT QA analysis
Quality assurance (QA) systems for intensity‐modulated radiation therapy (IMRT) have become standard tools in modern clinical medical physics departments. However, because formalized industry standards or recommendations from professional societies have yet to be defined, methods of IMRT QA analysis...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722600/ https://www.ncbi.nlm.nih.gov/pubmed/17712302 http://dx.doi.org/10.1120/jacmp.v8i3.2448 |
_version_ | 1783285051498168320 |
---|---|
author | Nelms, Benjamin E. Simon, Jeff A. |
author_facet | Nelms, Benjamin E. Simon, Jeff A. |
author_sort | Nelms, Benjamin E. |
collection | PubMed |
description | Quality assurance (QA) systems for intensity‐modulated radiation therapy (IMRT) have become standard tools in modern clinical medical physics departments. However, because formalized industry standards or recommendations from professional societies have yet to be defined, methods of IMRT QA analysis vary from institution to institution. Understanding where matters stand today is an important step toward improving the effectiveness of IMRT QA and developing standards. We therefore conducted an IMRT QA survey. This particular survey was limited to users of an electronic two‐dimensional diode array device, but we took care to keep the questions as general and useful as possible. The online survey polled institutions (one survey per institution) on a collection of questions about methods of IMRT QA. The topics were general to the IMRT QA analysis methods common to all IMRT systems; none of the questions was vendor‐ or product‐specific. Survey results showed that a significant proportion of responding institutions (32.8%) use the single‐gantry‐angle composite method for IMRT QA analysis instead of field‐by‐field analysis. Most institutions perform absolute dose comparisons rather than relative dose comparisons, with the 3% criterion being used most often for the percentage difference analysis, and the 3 mm criterion for distance‐to‐agreement analysis. The most prevalent standard for acceptance testing is the combined 3% and 3 mm criteria. A significant percentage of responding institutions report not yet having standard benchmarks for acceptance testing—specifically, 26.6%, 35.3%, and 67.6% had not yet established standard acceptance criteria for prostate, head and neck, and breast IMRT respectively. This survey helps in understanding how institutions perform IMRT QA analysis today. This understanding will help to move institutions toward more standardized acceptance testing. But before standards are defined, it would be useful to connect the conventional planar QA analyses to their resulting impact on the overall plan, using clinically relevant metrics (such as estimated deviations in dose–volume histograms). PACS numbers: 87.50.Gi, 87.52.Df, 87.52.Px, 87.53.Dq, 87.53.Tf, 87.53.Kn, 87.56.Fc |
format | Online Article Text |
id | pubmed-5722600 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57226002018-04-02 A survey on planar IMRT QA analysis Nelms, Benjamin E. Simon, Jeff A. J Appl Clin Med Phys Radiation Oncology Physics Quality assurance (QA) systems for intensity‐modulated radiation therapy (IMRT) have become standard tools in modern clinical medical physics departments. However, because formalized industry standards or recommendations from professional societies have yet to be defined, methods of IMRT QA analysis vary from institution to institution. Understanding where matters stand today is an important step toward improving the effectiveness of IMRT QA and developing standards. We therefore conducted an IMRT QA survey. This particular survey was limited to users of an electronic two‐dimensional diode array device, but we took care to keep the questions as general and useful as possible. The online survey polled institutions (one survey per institution) on a collection of questions about methods of IMRT QA. The topics were general to the IMRT QA analysis methods common to all IMRT systems; none of the questions was vendor‐ or product‐specific. Survey results showed that a significant proportion of responding institutions (32.8%) use the single‐gantry‐angle composite method for IMRT QA analysis instead of field‐by‐field analysis. Most institutions perform absolute dose comparisons rather than relative dose comparisons, with the 3% criterion being used most often for the percentage difference analysis, and the 3 mm criterion for distance‐to‐agreement analysis. The most prevalent standard for acceptance testing is the combined 3% and 3 mm criteria. A significant percentage of responding institutions report not yet having standard benchmarks for acceptance testing—specifically, 26.6%, 35.3%, and 67.6% had not yet established standard acceptance criteria for prostate, head and neck, and breast IMRT respectively. This survey helps in understanding how institutions perform IMRT QA analysis today. This understanding will help to move institutions toward more standardized acceptance testing. But before standards are defined, it would be useful to connect the conventional planar QA analyses to their resulting impact on the overall plan, using clinically relevant metrics (such as estimated deviations in dose–volume histograms). PACS numbers: 87.50.Gi, 87.52.Df, 87.52.Px, 87.53.Dq, 87.53.Tf, 87.53.Kn, 87.56.Fc John Wiley and Sons Inc. 2007-07-17 /pmc/articles/PMC5722600/ /pubmed/17712302 http://dx.doi.org/10.1120/jacmp.v8i3.2448 Text en © 2007 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Nelms, Benjamin E. Simon, Jeff A. A survey on planar IMRT QA analysis |
title | A survey on planar IMRT QA analysis |
title_full | A survey on planar IMRT QA analysis |
title_fullStr | A survey on planar IMRT QA analysis |
title_full_unstemmed | A survey on planar IMRT QA analysis |
title_short | A survey on planar IMRT QA analysis |
title_sort | survey on planar imrt qa analysis |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722600/ https://www.ncbi.nlm.nih.gov/pubmed/17712302 http://dx.doi.org/10.1120/jacmp.v8i3.2448 |
work_keys_str_mv | AT nelmsbenjamine asurveyonplanarimrtqaanalysis AT simonjeffa asurveyonplanarimrtqaanalysis AT nelmsbenjamine surveyonplanarimrtqaanalysis AT simonjeffa surveyonplanarimrtqaanalysis |