Cargando…
Effect of skull shape approximations in Gamma Knife dose calculations
Doses in Leksell GammaPlan (Elekta, Stockholm, Sweden) are calculated for each shot by summing the contribution from the 201 radiation beams emitted by the Gamma Knife (Elekta), weighted for attenuation in the tissue traversed. The patient's head is modeled based on 24 skull measurements, from...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722611/ https://www.ncbi.nlm.nih.gov/pubmed/17712300 http://dx.doi.org/10.1120/jacmp.v8i3.2377 |
_version_ | 1783285054222368768 |
---|---|
author | Berndt, Anita Beck, James |
author_facet | Berndt, Anita Beck, James |
author_sort | Berndt, Anita |
collection | PubMed |
description | Doses in Leksell GammaPlan (Elekta, Stockholm, Sweden) are calculated for each shot by summing the contribution from the 201 radiation beams emitted by the Gamma Knife (Elekta), weighted for attenuation in the tissue traversed. The patient's head is modeled based on 24 skull measurements, from which the depth to the calculation point is determined for each beam. The limited number of measurement points associated with this approach can result in substantial discrepancies between the skull model used for dose calculations and the actual skull contour from computed tomography or magnetic resonance data. A review of 24 patients found that differences between the actual and approximated skull shape gave treatment time errors as large as 4.1%, although in most instances, the errors were less than 1%. The conclusion was that the Leksell GammaPlan head model provides a quick and convenient approach for specifying the shape of the patient's head in all but extreme cases, where discrepancies as large as ~5% can result. PACS number: 87.53.Ly |
format | Online Article Text |
id | pubmed-5722611 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57226112018-04-02 Effect of skull shape approximations in Gamma Knife dose calculations Berndt, Anita Beck, James J Appl Clin Med Phys Radiation Oncology Physics Doses in Leksell GammaPlan (Elekta, Stockholm, Sweden) are calculated for each shot by summing the contribution from the 201 radiation beams emitted by the Gamma Knife (Elekta), weighted for attenuation in the tissue traversed. The patient's head is modeled based on 24 skull measurements, from which the depth to the calculation point is determined for each beam. The limited number of measurement points associated with this approach can result in substantial discrepancies between the skull model used for dose calculations and the actual skull contour from computed tomography or magnetic resonance data. A review of 24 patients found that differences between the actual and approximated skull shape gave treatment time errors as large as 4.1%, although in most instances, the errors were less than 1%. The conclusion was that the Leksell GammaPlan head model provides a quick and convenient approach for specifying the shape of the patient's head in all but extreme cases, where discrepancies as large as ~5% can result. PACS number: 87.53.Ly John Wiley and Sons Inc. 2007-07-17 /pmc/articles/PMC5722611/ /pubmed/17712300 http://dx.doi.org/10.1120/jacmp.v8i3.2377 Text en © 2007 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Berndt, Anita Beck, James Effect of skull shape approximations in Gamma Knife dose calculations |
title | Effect of skull shape approximations in Gamma Knife dose calculations |
title_full | Effect of skull shape approximations in Gamma Knife dose calculations |
title_fullStr | Effect of skull shape approximations in Gamma Knife dose calculations |
title_full_unstemmed | Effect of skull shape approximations in Gamma Knife dose calculations |
title_short | Effect of skull shape approximations in Gamma Knife dose calculations |
title_sort | effect of skull shape approximations in gamma knife dose calculations |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722611/ https://www.ncbi.nlm.nih.gov/pubmed/17712300 http://dx.doi.org/10.1120/jacmp.v8i3.2377 |
work_keys_str_mv | AT berndtanita effectofskullshapeapproximationsingammaknifedosecalculations AT beckjames effectofskullshapeapproximationsingammaknifedosecalculations |