Current treatment planning systems (TPSs) for partial breast irradiation using the MammoSite brachytherapy applicator (Cytyc Corporation, Marlborough, MA) often neglect the effect of inhomogeneity, leading to potential inaccuracies in dose distributions. Previous publications either have studied onl...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Zhengdong, Parsai, E. Ishmael, Feldmeier, John J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722616/
https://www.ncbi.nlm.nih.gov/pubmed/18449153
http://dx.doi.org/10.1120/jacmp.v8i4.2669
_version_ 1783285055504777216
author Zhang, Zhengdong
Parsai, E. Ishmael
Feldmeier, John J.
author_facet Zhang, Zhengdong
Parsai, E. Ishmael
Feldmeier, John J.
author_sort Zhang, Zhengdong
collection PubMed
description Current treatment planning systems (TPSs) for partial breast irradiation using the MammoSite brachytherapy applicator (Cytyc Corporation, Marlborough, MA) often neglect the effect of inhomogeneity, leading to potential inaccuracies in dose distributions. Previous publications either have studied only a planar dose perturbation along the bisector of the source or have paid little attention to the anisotropy effect of the system. In the present study, we investigated the attenuation‐corrected radial dose and anisotropy functions in a form parallel to the updated American Association of Physicists in Medicine TG‐43 formalism. This work quantitatively delineates the inaccuracies in dose distributions in three‐dimensional space. Monte Carlo N‐particle transport code simulations in coupled photon–electron transport were used to quantify the changes in dose deposition and distribution caused by the increased attenuation coefficient of iodine‐based contrast solution. The source geometry was that of the VariSource wire model VS2000 (Varian Medical Systems, Palo Alto, CA). The concentration of the iodine‐based solution was varied from 5% to 25% by volume, a range recommended by the balloon's manufacturer. Balloon diameters of 4, 5, and 6 cm were simulated. Dose rates at the typical prescription line (1 cm away from the balloon surface) were determined for various polar angles. The computations showed that the dose rate reduction throughout the entire region of interest ranged from 0.64% for the smallest balloon diameter and contrast concentration to 6.17% for the largest balloon diameter and contrast concentration. The corrected radial dose function has a predominant influence on dose reduction, but the corrected anisotropy functions explain only the effect at the MammoSite system poles. By applying the corrected radial dose and anisotropy functions to TPSs, the attenuation effect can be reduced to the minimum. PACS number: 87.53.‐j
format Online
Article
Text
id pubmed-5722616
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57226162018-04-02 Three‐dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations Zhang, Zhengdong Parsai, E. Ishmael Feldmeier, John J. J Appl Clin Med Phys Radiation Oncology Physics Current treatment planning systems (TPSs) for partial breast irradiation using the MammoSite brachytherapy applicator (Cytyc Corporation, Marlborough, MA) often neglect the effect of inhomogeneity, leading to potential inaccuracies in dose distributions. Previous publications either have studied only a planar dose perturbation along the bisector of the source or have paid little attention to the anisotropy effect of the system. In the present study, we investigated the attenuation‐corrected radial dose and anisotropy functions in a form parallel to the updated American Association of Physicists in Medicine TG‐43 formalism. This work quantitatively delineates the inaccuracies in dose distributions in three‐dimensional space. Monte Carlo N‐particle transport code simulations in coupled photon–electron transport were used to quantify the changes in dose deposition and distribution caused by the increased attenuation coefficient of iodine‐based contrast solution. The source geometry was that of the VariSource wire model VS2000 (Varian Medical Systems, Palo Alto, CA). The concentration of the iodine‐based solution was varied from 5% to 25% by volume, a range recommended by the balloon's manufacturer. Balloon diameters of 4, 5, and 6 cm were simulated. Dose rates at the typical prescription line (1 cm away from the balloon surface) were determined for various polar angles. The computations showed that the dose rate reduction throughout the entire region of interest ranged from 0.64% for the smallest balloon diameter and contrast concentration to 6.17% for the largest balloon diameter and contrast concentration. The corrected radial dose function has a predominant influence on dose reduction, but the corrected anisotropy functions explain only the effect at the MammoSite system poles. By applying the corrected radial dose and anisotropy functions to TPSs, the attenuation effect can be reduced to the minimum. PACS number: 87.53.‐j John Wiley and Sons Inc. 2007-11-20 /pmc/articles/PMC5722616/ /pubmed/18449153 http://dx.doi.org/10.1120/jacmp.v8i4.2669 Text en © 2007 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Zhang, Zhengdong
Parsai, E. Ishmael
Feldmeier, John J.
Three‐dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations
title Three‐dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations
title_full Three‐dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations
title_fullStr Three‐dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations
title_full_unstemmed Three‐dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations
title_short Three‐dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations
title_sort three‐dimensional quantitative dose reduction analysis in mammosite balloon by monte carlo calculations
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722616/
https://www.ncbi.nlm.nih.gov/pubmed/18449153
http://dx.doi.org/10.1120/jacmp.v8i4.2669
work_keys_str_mv AT zhangzhengdong threedimensionalquantitativedosereductionanalysisinmammositeballoonbymontecarlocalculations
AT parsaieishmael threedimensionalquantitativedosereductionanalysisinmammositeballoonbymontecarlocalculations
AT feldmeierjohnj threedimensionalquantitativedosereductionanalysisinmammositeballoonbymontecarlocalculations