Verification procedure for isocentric alignment of proton beams
We present a technique—based on the Lutz, Winston, and Maleki test used in stereotactic linear accelerator radiosurgery—for verifying whether proton beams are being delivered within the required spatial coincidence with the gantry mechanical isocenter. Our procedure uses a proton beam that is collim...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722618/ https://www.ncbi.nlm.nih.gov/pubmed/18449154 http://dx.doi.org/10.1120/jacmp.v8i4.2671 |
_version_ | 1783285056330006528 |
---|---|
author | Ciangaru, George Yang, James N. Oliver, Patrick J. Bues, Martin Zhu, Mengping Nakagawa, Fumio Chiba, Hitoshi Nakamura, Shin Yoshino, Hirofumi Umezawa, Mosumi Smith, Alfred R. |
author_facet | Ciangaru, George Yang, James N. Oliver, Patrick J. Bues, Martin Zhu, Mengping Nakagawa, Fumio Chiba, Hitoshi Nakamura, Shin Yoshino, Hirofumi Umezawa, Mosumi Smith, Alfred R. |
author_sort | Ciangaru, George |
collection | PubMed |
description | We present a technique—based on the Lutz, Winston, and Maleki test used in stereotactic linear accelerator radiosurgery—for verifying whether proton beams are being delivered within the required spatial coincidence with the gantry mechanical isocenter. Our procedure uses a proton beam that is collimated by a circular aperture at its central axis and is then intercepted by a small steel sphere rigidly supported by the patient couch. A laser tracker measurement system and a correction algorithm for couch position assures precise positioning of the steel sphere at the mechanical isocenter of the gantry. A film‐based radiation dosimetry technique, chosen for the good spatial resolution it achieves, records the proton dose distribution for optical image analysis. The optical image obtained presents a circular high‐dose region surrounding a lower‐dose area corresponding to the proton beam absorption by the steel sphere, thereby providing a measure of the beam alignment with the mechanical isocenter. We found the self‐developing Gafchromic EBT film (International Specialty Products, Wayne, NJ) and commercial Epson 10000 XL flatbed scanner (Epson America, Long Beach, CA) to be accurate and efficient tools. The positions of the gantry mechanical and proton beam isocenters, as recorded on film, were clearly identifiable within the scanning resolution used for routine alignment testing (0.17 mm per pixel). The mean displacement of the collimated proton beam from the gantry mechanical isocenter was [Formula: see text] for the gantry positions tested, which was well within the maximum deviation of 0.50 mm accepted at the Proton Therapy Center in Houston. PACS numbers: 87.53.Xd, 87.53.Oc, 87.56.‐v, 87.66.‐a, 87.56.Fc |
format | Online Article Text |
id | pubmed-5722618 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57226182018-04-02 Verification procedure for isocentric alignment of proton beams Ciangaru, George Yang, James N. Oliver, Patrick J. Bues, Martin Zhu, Mengping Nakagawa, Fumio Chiba, Hitoshi Nakamura, Shin Yoshino, Hirofumi Umezawa, Mosumi Smith, Alfred R. J Appl Clin Med Phys Radiation Oncology Physics We present a technique—based on the Lutz, Winston, and Maleki test used in stereotactic linear accelerator radiosurgery—for verifying whether proton beams are being delivered within the required spatial coincidence with the gantry mechanical isocenter. Our procedure uses a proton beam that is collimated by a circular aperture at its central axis and is then intercepted by a small steel sphere rigidly supported by the patient couch. A laser tracker measurement system and a correction algorithm for couch position assures precise positioning of the steel sphere at the mechanical isocenter of the gantry. A film‐based radiation dosimetry technique, chosen for the good spatial resolution it achieves, records the proton dose distribution for optical image analysis. The optical image obtained presents a circular high‐dose region surrounding a lower‐dose area corresponding to the proton beam absorption by the steel sphere, thereby providing a measure of the beam alignment with the mechanical isocenter. We found the self‐developing Gafchromic EBT film (International Specialty Products, Wayne, NJ) and commercial Epson 10000 XL flatbed scanner (Epson America, Long Beach, CA) to be accurate and efficient tools. The positions of the gantry mechanical and proton beam isocenters, as recorded on film, were clearly identifiable within the scanning resolution used for routine alignment testing (0.17 mm per pixel). The mean displacement of the collimated proton beam from the gantry mechanical isocenter was [Formula: see text] for the gantry positions tested, which was well within the maximum deviation of 0.50 mm accepted at the Proton Therapy Center in Houston. PACS numbers: 87.53.Xd, 87.53.Oc, 87.56.‐v, 87.66.‐a, 87.56.Fc John Wiley and Sons Inc. 2007-10-24 /pmc/articles/PMC5722618/ /pubmed/18449154 http://dx.doi.org/10.1120/jacmp.v8i4.2671 Text en © 2007 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Ciangaru, George Yang, James N. Oliver, Patrick J. Bues, Martin Zhu, Mengping Nakagawa, Fumio Chiba, Hitoshi Nakamura, Shin Yoshino, Hirofumi Umezawa, Mosumi Smith, Alfred R. Verification procedure for isocentric alignment of proton beams |
title | Verification procedure for isocentric alignment of proton beams |
title_full | Verification procedure for isocentric alignment of proton beams |
title_fullStr | Verification procedure for isocentric alignment of proton beams |
title_full_unstemmed | Verification procedure for isocentric alignment of proton beams |
title_short | Verification procedure for isocentric alignment of proton beams |
title_sort | verification procedure for isocentric alignment of proton beams |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722618/ https://www.ncbi.nlm.nih.gov/pubmed/18449154 http://dx.doi.org/10.1120/jacmp.v8i4.2671 |
work_keys_str_mv | AT ciangarugeorge verificationprocedureforisocentricalignmentofprotonbeams AT yangjamesn verificationprocedureforisocentricalignmentofprotonbeams AT oliverpatrickj verificationprocedureforisocentricalignmentofprotonbeams AT buesmartin verificationprocedureforisocentricalignmentofprotonbeams AT zhumengping verificationprocedureforisocentricalignmentofprotonbeams AT nakagawafumio verificationprocedureforisocentricalignmentofprotonbeams AT chibahitoshi verificationprocedureforisocentricalignmentofprotonbeams AT nakamurashin verificationprocedureforisocentricalignmentofprotonbeams AT yoshinohirofumi verificationprocedureforisocentricalignmentofprotonbeams AT umezawamosumi verificationprocedureforisocentricalignmentofprotonbeams AT smithalfredr verificationprocedureforisocentricalignmentofprotonbeams |