Validation of physics improvements for IMRT with a commercial treatment‐planning system
A new Pinnacle 3D treatment‐planning system software release has recently become available (v7.4, Philips Radiation Oncology Systems, Milpitas, CA), which supports modeling of rounded multileaf collimator (MLC) leaf ends; it also includes a number of other software enhancements intended to improve t...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2005
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5723472/ https://www.ncbi.nlm.nih.gov/pubmed/15940214 http://dx.doi.org/10.1120/jacmp.v6i2.2083 |
_version_ | 1783285219544006656 |
---|---|
author | Cadman, Patrick McNutt, Todd Bzdusek, Karl |
author_facet | Cadman, Patrick McNutt, Todd Bzdusek, Karl |
author_sort | Cadman, Patrick |
collection | PubMed |
description | A new Pinnacle 3D treatment‐planning system software release has recently become available (v7.4, Philips Radiation Oncology Systems, Milpitas, CA), which supports modeling of rounded multileaf collimator (MLC) leaf ends; it also includes a number of other software enhancements intended to improve the overall dose calculation accuracy. In this report, we provide a general discussion of the dose calculation algorithm and new beam‐modeling parameters. The accuracy of a diode dosimeter was established for measurement of MLC‐shaped beam profiles required by the new software version by comparison with film and ion chamber measurements in various regions of the field. The results suggest that a suitable diode or other small volume dosimeter with appropriate energy sensitivity should be used to obtain profiles for commissioning the planning system. Film should be used with caution, especially for larger field profile measurements. The dose calculation algorithm and modeling parameters chosen were validated through various test field measurements including a bar pattern, a strip pattern, and a clinical head and neck IMRT field. For the bar and strip patterns, the agreement between Pinnacle calculations and diode measurements was generally very good. These tests were helpful in establishing the new model parameter values, especially tongue‐and‐groove width, additional interleaf leakage, rounded leaf tip radius, and MLC transmission. For the clinical head and neck field, the comparison between Pinnacle and film measurements showed regions of approximately 2 cGy under‐ or overdose. However, the Pinnacle calculations agreed with diode measurements at all points to within 1 cGy or 1% of the maximum dose for the field (67 cGy). The greatest discrepancy between film and diode measurements for the clinical field (maximum of 2.8%) occurred in low‐dose regions in the central part of the field. The disagreement may be due to the overresponse of film to scattered radiation in the low‐dose regions, which have significant shielding by the MLCs. PACS numbers: 87.53.Bn, 87.53.Dq |
format | Online Article Text |
id | pubmed-5723472 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2005 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57234722018-04-02 Validation of physics improvements for IMRT with a commercial treatment‐planning system Cadman, Patrick McNutt, Todd Bzdusek, Karl J Appl Clin Med Phys Radiation Oncology Physics A new Pinnacle 3D treatment‐planning system software release has recently become available (v7.4, Philips Radiation Oncology Systems, Milpitas, CA), which supports modeling of rounded multileaf collimator (MLC) leaf ends; it also includes a number of other software enhancements intended to improve the overall dose calculation accuracy. In this report, we provide a general discussion of the dose calculation algorithm and new beam‐modeling parameters. The accuracy of a diode dosimeter was established for measurement of MLC‐shaped beam profiles required by the new software version by comparison with film and ion chamber measurements in various regions of the field. The results suggest that a suitable diode or other small volume dosimeter with appropriate energy sensitivity should be used to obtain profiles for commissioning the planning system. Film should be used with caution, especially for larger field profile measurements. The dose calculation algorithm and modeling parameters chosen were validated through various test field measurements including a bar pattern, a strip pattern, and a clinical head and neck IMRT field. For the bar and strip patterns, the agreement between Pinnacle calculations and diode measurements was generally very good. These tests were helpful in establishing the new model parameter values, especially tongue‐and‐groove width, additional interleaf leakage, rounded leaf tip radius, and MLC transmission. For the clinical head and neck field, the comparison between Pinnacle and film measurements showed regions of approximately 2 cGy under‐ or overdose. However, the Pinnacle calculations agreed with diode measurements at all points to within 1 cGy or 1% of the maximum dose for the field (67 cGy). The greatest discrepancy between film and diode measurements for the clinical field (maximum of 2.8%) occurred in low‐dose regions in the central part of the field. The disagreement may be due to the overresponse of film to scattered radiation in the low‐dose regions, which have significant shielding by the MLCs. PACS numbers: 87.53.Bn, 87.53.Dq John Wiley and Sons Inc. 2005-05-21 /pmc/articles/PMC5723472/ /pubmed/15940214 http://dx.doi.org/10.1120/jacmp.v6i2.2083 Text en © 2005 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Cadman, Patrick McNutt, Todd Bzdusek, Karl Validation of physics improvements for IMRT with a commercial treatment‐planning system |
title | Validation of physics improvements for IMRT with a commercial treatment‐planning system |
title_full | Validation of physics improvements for IMRT with a commercial treatment‐planning system |
title_fullStr | Validation of physics improvements for IMRT with a commercial treatment‐planning system |
title_full_unstemmed | Validation of physics improvements for IMRT with a commercial treatment‐planning system |
title_short | Validation of physics improvements for IMRT with a commercial treatment‐planning system |
title_sort | validation of physics improvements for imrt with a commercial treatment‐planning system |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5723472/ https://www.ncbi.nlm.nih.gov/pubmed/15940214 http://dx.doi.org/10.1120/jacmp.v6i2.2083 |
work_keys_str_mv | AT cadmanpatrick validationofphysicsimprovementsforimrtwithacommercialtreatmentplanningsystem AT mcnutttodd validationofphysicsimprovementsforimrtwithacommercialtreatmentplanningsystem AT bzdusekkarl validationofphysicsimprovementsforimrtwithacommercialtreatmentplanningsystem |