Improving a scissor‐action couch for conformal arc radiotherapy and radiosurgery
We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2004
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5723480/ https://www.ncbi.nlm.nih.gov/pubmed/15753940 http://dx.doi.org/10.1120/jacmp.v5i3.2026 |
_version_ | 1783285221477580800 |
---|---|
author | Li, Kaile Yu, Cedric X. Ma, Lijun |
author_facet | Li, Kaile Yu, Cedric X. Ma, Lijun |
author_sort | Li, Kaile |
collection | PubMed |
description | We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the couch: turn‐knob harnesses, double‐track alignment plates, and a drop‐in rod that attaches the couch to the concrete floor. These add‐on components minimize the intercomponent motion of the couch's scissor elevator, which allows consistent treatment setup. The accuracy of our isocenter couch alignment is an improvement over the above devices, within 1 mm of their accuracy. The couch has been used with over 15 patients and with over 50 modulated conformal arc treatment deliveries at our institution. PACS numbers: 87.53.Kn, 87.53.Ly, 87.56.Da |
format | Online Article Text |
id | pubmed-5723480 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2004 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57234802018-04-02 Improving a scissor‐action couch for conformal arc radiotherapy and radiosurgery Li, Kaile Yu, Cedric X. Ma, Lijun J Appl Clin Med Phys Radiation Oncology Physics We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the couch: turn‐knob harnesses, double‐track alignment plates, and a drop‐in rod that attaches the couch to the concrete floor. These add‐on components minimize the intercomponent motion of the couch's scissor elevator, which allows consistent treatment setup. The accuracy of our isocenter couch alignment is an improvement over the above devices, within 1 mm of their accuracy. The couch has been used with over 15 patients and with over 50 modulated conformal arc treatment deliveries at our institution. PACS numbers: 87.53.Kn, 87.53.Ly, 87.56.Da John Wiley and Sons Inc. 2004-10-21 /pmc/articles/PMC5723480/ /pubmed/15753940 http://dx.doi.org/10.1120/jacmp.v5i3.2026 Text en © 2004 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Li, Kaile Yu, Cedric X. Ma, Lijun Improving a scissor‐action couch for conformal arc radiotherapy and radiosurgery |
title | Improving a scissor‐action couch for conformal arc radiotherapy and radiosurgery |
title_full | Improving a scissor‐action couch for conformal arc radiotherapy and radiosurgery |
title_fullStr | Improving a scissor‐action couch for conformal arc radiotherapy and radiosurgery |
title_full_unstemmed | Improving a scissor‐action couch for conformal arc radiotherapy and radiosurgery |
title_short | Improving a scissor‐action couch for conformal arc radiotherapy and radiosurgery |
title_sort | improving a scissor‐action couch for conformal arc radiotherapy and radiosurgery |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5723480/ https://www.ncbi.nlm.nih.gov/pubmed/15753940 http://dx.doi.org/10.1120/jacmp.v5i3.2026 |
work_keys_str_mv | AT likaile improvingascissoractioncouchforconformalarcradiotherapyandradiosurgery AT yucedricx improvingascissoractioncouchforconformalarcradiotherapyandradiosurgery AT malijun improvingascissoractioncouchforconformalarcradiotherapyandradiosurgery |