Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures
A hospital‐based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field‐guided navigation system. Our resul...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2005
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5723488/ https://www.ncbi.nlm.nih.gov/pubmed/16143799 http://dx.doi.org/10.1120/jacmp.v6i3.2111 |
_version_ | 1783285223335657472 |
---|---|
author | Chu, James C.H. Hsi, Wen Chien Hubbard, Lincoln Zhang, Yunkai Bernard, Damian Reeder, Pamela Lopes, Demetrius |
author_facet | Chu, James C.H. Hsi, Wen Chien Hubbard, Lincoln Zhang, Yunkai Bernard, Damian Reeder, Pamela Lopes, Demetrius |
author_sort | Chu, James C.H. |
collection | PubMed |
description | A hospital‐based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field‐guided navigation system. Our results show that the system's radiological imaging components produce images with quality similar to that produced by other modern fluoroscopic devices. The system's magnetic navigation components also deflect the wire and catheter tips toward the intended direction. The physician, however, will have to oversteer the wire or catheter when defining the steering angle during the procedure. The MGS could be clinically useful in device navigation deflection and vessel access. PACS numbers: 07.55.Db, 07.85.‐m |
format | Online Article Text |
id | pubmed-5723488 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2005 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57234882018-04-02 Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures Chu, James C.H. Hsi, Wen Chien Hubbard, Lincoln Zhang, Yunkai Bernard, Damian Reeder, Pamela Lopes, Demetrius J Appl Clin Med Phys Other Topics A hospital‐based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field‐guided navigation system. Our results show that the system's radiological imaging components produce images with quality similar to that produced by other modern fluoroscopic devices. The system's magnetic navigation components also deflect the wire and catheter tips toward the intended direction. The physician, however, will have to oversteer the wire or catheter when defining the steering angle during the procedure. The MGS could be clinically useful in device navigation deflection and vessel access. PACS numbers: 07.55.Db, 07.85.‐m John Wiley and Sons Inc. 2005-08-17 /pmc/articles/PMC5723488/ /pubmed/16143799 http://dx.doi.org/10.1120/jacmp.v6i3.2111 Text en © 2005 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Other Topics Chu, James C.H. Hsi, Wen Chien Hubbard, Lincoln Zhang, Yunkai Bernard, Damian Reeder, Pamela Lopes, Demetrius Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures |
title | Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures |
title_full | Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures |
title_fullStr | Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures |
title_full_unstemmed | Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures |
title_short | Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures |
title_sort | performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures |
topic | Other Topics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5723488/ https://www.ncbi.nlm.nih.gov/pubmed/16143799 http://dx.doi.org/10.1120/jacmp.v6i3.2111 |
work_keys_str_mv | AT chujamesch performanceofmagneticfieldguidednavigationsystemforinterventionalneurosurgicalandcardiacprocedures AT hsiwenchien performanceofmagneticfieldguidednavigationsystemforinterventionalneurosurgicalandcardiacprocedures AT hubbardlincoln performanceofmagneticfieldguidednavigationsystemforinterventionalneurosurgicalandcardiacprocedures AT zhangyunkai performanceofmagneticfieldguidednavigationsystemforinterventionalneurosurgicalandcardiacprocedures AT bernarddamian performanceofmagneticfieldguidednavigationsystemforinterventionalneurosurgicalandcardiacprocedures AT reederpamela performanceofmagneticfieldguidednavigationsystemforinterventionalneurosurgicalandcardiacprocedures AT lopesdemetrius performanceofmagneticfieldguidednavigationsystemforinterventionalneurosurgicalandcardiacprocedures |