Traditional external beam radiotherapy of gynecological cancer consists of a 3D, four‐field‐box technique. The radiation treatment area is a large region of normal tissue, with greater inhomogeneity over the treatment volume, which could benefit more with intensity‐modulated radiation therapy (IMRT)...
Autores principales: | Fung, Albert Y.C., Enke, Charles A., Ayyangar, Komanduri M., Thompson, Robert B., Zhen, Weining, Raman, Natarajan V., Djajaputra, David, Li, Sicong, Nehru, Ramasamy M., Pillai, Sushakumari, Sourivong, Paul, Headley, Mary, Yager, Ann L. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2005
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5723493/ https://www.ncbi.nlm.nih.gov/pubmed/16143791 http://dx.doi.org/10.1120/jacmp.v6i3.2087 |
Ejemplares similares
-
On correlations in IMRT planning aims
por: Roy, Arkajyoti, et al.
Publicado: (2016) -
In‐house quality check of external beam plans using 3D treatment planning systems — a DVH comparison
por: Kumar, Ayyalasomayajula Anil, et al.
Publicado: (2016) -
Comparison of Dosimetric Parameters and Clinical Outcomes in Inversely Planned Intensity-Modulated Radiotherapy (IMRT) and Field-in-Field Forward Planned IMRT for the Treatment of Breast Cancer
por: Azharuddin, SK, et al.
Publicado: (2022) -
Automated IMRT planning with regional optimization using planning scripts
por: Xhaferllari, Ilma, et al.
Publicado: (2013) -
Verification of inverse planning and treatment delivery for segmental IMRT
por: Bedford, James L., et al.
Publicado: (2004)