Cargando…

Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program

A comparison of isocenter dose calculated by a commercial intensity modulated radiation therapy treatment planning system and independent monitor unit verification calculation (MUVC) software was made. The percent disparity between the treatment plan and MUVC doses were calculated for 507 treatments...

Descripción completa

Detalles Bibliográficos
Autores principales: Haslam, J. J., Bonta, D. V., Lujan, A. E., Rash, C., Jackson, W., Roeske, J. C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2003
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724446/
https://www.ncbi.nlm.nih.gov/pubmed/12841793
http://dx.doi.org/10.1120/jacmp.v4i3.2519
_version_ 1783285360965451776
author Haslam, J. J.
Bonta, D. V.
Lujan, A. E.
Rash, C.
Jackson, W.
Roeske, J. C.
author_facet Haslam, J. J.
Bonta, D. V.
Lujan, A. E.
Rash, C.
Jackson, W.
Roeske, J. C.
author_sort Haslam, J. J.
collection PubMed
description A comparison of isocenter dose calculated by a commercial intensity modulated radiation therapy treatment planning system and independent monitor unit verification calculation (MUVC) software was made. The percent disparity between the treatment plan and MUVC doses were calculated for 507 treatments (head and neck, prostate, abdomen, female pelvis, rectum and anus, and miscellaneous) from 303 patients. The MUVC calculated dose was, on average, 1.4% higher than the treatment planning dose, with a 1.2% standard deviation. The distribution of the disparities appeared to be Gaussian in shape with some variation by treatment site. Based on our analysis, disparities outside the range of [Formula: see text] about the mean value should be checked and resolved prior to treatment delivery. PACS number(s): 87.53.–j, 87.66.–a
format Online
Article
Text
id pubmed-5724446
institution National Center for Biotechnology Information
language English
publishDate 2003
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57244462018-04-02 Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program Haslam, J. J. Bonta, D. V. Lujan, A. E. Rash, C. Jackson, W. Roeske, J. C. J Appl Clin Med Phys Radiation Oncology Physics A comparison of isocenter dose calculated by a commercial intensity modulated radiation therapy treatment planning system and independent monitor unit verification calculation (MUVC) software was made. The percent disparity between the treatment plan and MUVC doses were calculated for 507 treatments (head and neck, prostate, abdomen, female pelvis, rectum and anus, and miscellaneous) from 303 patients. The MUVC calculated dose was, on average, 1.4% higher than the treatment planning dose, with a 1.2% standard deviation. The distribution of the disparities appeared to be Gaussian in shape with some variation by treatment site. Based on our analysis, disparities outside the range of [Formula: see text] about the mean value should be checked and resolved prior to treatment delivery. PACS number(s): 87.53.–j, 87.66.–a John Wiley and Sons Inc. 2003-06-01 /pmc/articles/PMC5724446/ /pubmed/12841793 http://dx.doi.org/10.1120/jacmp.v4i3.2519 Text en © 2003 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Haslam, J. J.
Bonta, D. V.
Lujan, A. E.
Rash, C.
Jackson, W.
Roeske, J. C.
Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program
title Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program
title_full Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program
title_fullStr Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program
title_full_unstemmed Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program
title_short Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program
title_sort comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724446/
https://www.ncbi.nlm.nih.gov/pubmed/12841793
http://dx.doi.org/10.1120/jacmp.v4i3.2519
work_keys_str_mv AT haslamjj comparisonofdosecalculatedbyanintensitymodulatedradiotherapytreatmentplanningsystemandanindependentmonitorunitverificationprogram
AT bontadv comparisonofdosecalculatedbyanintensitymodulatedradiotherapytreatmentplanningsystemandanindependentmonitorunitverificationprogram
AT lujanae comparisonofdosecalculatedbyanintensitymodulatedradiotherapytreatmentplanningsystemandanindependentmonitorunitverificationprogram
AT rashc comparisonofdosecalculatedbyanintensitymodulatedradiotherapytreatmentplanningsystemandanindependentmonitorunitverificationprogram
AT jacksonw comparisonofdosecalculatedbyanintensitymodulatedradiotherapytreatmentplanningsystemandanindependentmonitorunitverificationprogram
AT roeskejc comparisonofdosecalculatedbyanintensitymodulatedradiotherapytreatmentplanningsystemandanindependentmonitorunitverificationprogram