Technical note: The effect of the 4‐mm‐collimator output factor on gamma knife dose distributions

We present results of investigations of the clinical significance of variations in the value of the 4‐mm‐collimator output factor, [Formula: see text]. Changes in treatment volume, dose‐volume histograms (DVHs), and isodose distributions were studied, by varying [Formula: see text] up to 20%. The va...

Descripción completa

Detalles Bibliográficos
Autores principales: Gibbons, John P., Mihailidis, Dimitris, Worthington, Curtis, Alkhatib, Hassaan, Boulware, Raleigh, Clark, Robert, Dial, Burke, Neglia, William
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2003
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724451/
https://www.ncbi.nlm.nih.gov/pubmed/14604431
http://dx.doi.org/10.1120/jacmp.v4i4.2512
_version_ 1783285362198577152
author Gibbons, John P.
Mihailidis, Dimitris
Worthington, Curtis
Alkhatib, Hassaan
Boulware, Raleigh
Clark, Robert
Dial, Burke
Neglia, William
author_facet Gibbons, John P.
Mihailidis, Dimitris
Worthington, Curtis
Alkhatib, Hassaan
Boulware, Raleigh
Clark, Robert
Dial, Burke
Neglia, William
author_sort Gibbons, John P.
collection PubMed
description We present results of investigations of the clinical significance of variations in the value of the 4‐mm‐collimator output factor, [Formula: see text]. Changes in treatment volume, dose‐volume histograms (DVHs), and isodose distributions were studied, by varying [Formula: see text] up to 20%. The variations were performed on a sample of clinical patient treatment plans for which the 4 mm collimator was used. Although smaller effects are noted for the prescription isodose line, greater dosimetric changes occur for higher dose regions within the target. PACS number(s): 87.53.–j, 87.52.–g
format Online
Article
Text
id pubmed-5724451
institution National Center for Biotechnology Information
language English
publishDate 2003
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57244512018-04-02 Technical note: The effect of the 4‐mm‐collimator output factor on gamma knife dose distributions Gibbons, John P. Mihailidis, Dimitris Worthington, Curtis Alkhatib, Hassaan Boulware, Raleigh Clark, Robert Dial, Burke Neglia, William J Appl Clin Med Phys Technical Notes We present results of investigations of the clinical significance of variations in the value of the 4‐mm‐collimator output factor, [Formula: see text]. Changes in treatment volume, dose‐volume histograms (DVHs), and isodose distributions were studied, by varying [Formula: see text] up to 20%. The variations were performed on a sample of clinical patient treatment plans for which the 4 mm collimator was used. Although smaller effects are noted for the prescription isodose line, greater dosimetric changes occur for higher dose regions within the target. PACS number(s): 87.53.–j, 87.52.–g John Wiley and Sons Inc. 2003-09-01 /pmc/articles/PMC5724451/ /pubmed/14604431 http://dx.doi.org/10.1120/jacmp.v4i4.2512 Text en © 2003 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Gibbons, John P.
Mihailidis, Dimitris
Worthington, Curtis
Alkhatib, Hassaan
Boulware, Raleigh
Clark, Robert
Dial, Burke
Neglia, William
Technical note: The effect of the 4‐mm‐collimator output factor on gamma knife dose distributions
title Technical note: The effect of the 4‐mm‐collimator output factor on gamma knife dose distributions
title_full Technical note: The effect of the 4‐mm‐collimator output factor on gamma knife dose distributions
title_fullStr Technical note: The effect of the 4‐mm‐collimator output factor on gamma knife dose distributions
title_full_unstemmed Technical note: The effect of the 4‐mm‐collimator output factor on gamma knife dose distributions
title_short Technical note: The effect of the 4‐mm‐collimator output factor on gamma knife dose distributions
title_sort technical note: the effect of the 4‐mm‐collimator output factor on gamma knife dose distributions
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724451/
https://www.ncbi.nlm.nih.gov/pubmed/14604431
http://dx.doi.org/10.1120/jacmp.v4i4.2512
work_keys_str_mv AT gibbonsjohnp technicalnotetheeffectofthe4mmcollimatoroutputfactorongammaknifedosedistributions
AT mihailidisdimitris technicalnotetheeffectofthe4mmcollimatoroutputfactorongammaknifedosedistributions
AT worthingtoncurtis technicalnotetheeffectofthe4mmcollimatoroutputfactorongammaknifedosedistributions
AT alkhatibhassaan technicalnotetheeffectofthe4mmcollimatoroutputfactorongammaknifedosedistributions
AT boulwareraleigh technicalnotetheeffectofthe4mmcollimatoroutputfactorongammaknifedosedistributions
AT clarkrobert technicalnotetheeffectofthe4mmcollimatoroutputfactorongammaknifedosedistributions
AT dialburke technicalnotetheeffectofthe4mmcollimatoroutputfactorongammaknifedosedistributions
AT negliawilliam technicalnotetheeffectofthe4mmcollimatoroutputfactorongammaknifedosedistributions