The American Association of Physicists in Medicine Task Group 36 (AAPM TG‐36) data can be used to estimate peripheral dose (PD) distributions outside the primary radiation field. However, the report data does not apply to linear accelerators equipped with a multileaf collimator (MLC) and universal w...

Descripción completa

Detalles Bibliográficos
Autores principales: Mutic, Sasa, Esthappan, Jacqueline, Klein, Eric E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2002
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724532/
https://www.ncbi.nlm.nih.gov/pubmed/12383050
http://dx.doi.org/10.1120/jacmp.v3i4.2554
_version_ 1783285378057240576
author Mutic, Sasa
Esthappan, Jacqueline
Klein, Eric E.
author_facet Mutic, Sasa
Esthappan, Jacqueline
Klein, Eric E.
author_sort Mutic, Sasa
collection PubMed
description The American Association of Physicists in Medicine Task Group 36 (AAPM TG‐36) data can be used to estimate peripheral dose (PD) distributions outside the primary radiation field. However, the report data does not apply to linear accelerators equipped with a multileaf collimator (MLC) and universal wedge (UW). Tertiary multileaf collimators have been shown to significantly affect PD distributions and TG‐36 reported data. Measurements were performed to evaluate PD distributions for a linear accelerator equipped with a secondary MLC, backup diaphragms, and UW. This data can be used to compliment the TG‐36 report for estimation of doses to critical structures outside primary radiation fields. For the evaluated linear accelerator, an MLC is incorporated in the upper secondary collimator jaws. Backup shielding diaphragms are located underneath the MLC. At the nominal collimator position, the MLC and the backup diaphragm provide collimation primarily in the transverse direction. Conventional, solid tungsten‐alloy jaws, located underneath the backup diaphragms, provide secondary collimation in the longitudinal direction. The universal wedge provides dose modulation in the direction of the conventional jaws. Measurements were made with an ionization chamber inserted into a [Formula: see text] water‐equivalent plastic phantom with the secondary collimator and MLC settings of [Formula: see text] , and [Formula: see text] with and without UW. Data was acquired along the machine's longitudinal axis for 6, 10, and 18 MV photons. Peripheral dose distributions were measured with the collimator rotated to 0(°) and 270(°) for open field measurements and to 0(°), 180(°), and 270(°) for wedged fields (IEC 1217). This allowed evaluation of peripheral dose distributions as a function of collimator rotation. Wedged fields were normalized to deliver the same dose at the depth of maximum dose on the central axis as open fields. The measured PD distributions were generally comparable to data reported by TG‐36. At distances close to the field edge (less than 30 or 40 cm), the measured PD distributions were lower when the measurement point was shielded by solid jaws than with MLC and backup diaphragm. At longer distances, this trend reversed for all energies and evaluated field sizes. However, the difference in PD distribution with collimator rotation was not large enough to warrant strategic positioning of the collimator to reduce dose to critical structures outside the primary radiation field. Because internal scatter dominates close to the field edge, wedged PD distributions were comparable to open field doses at distances closer than 30 cm. However, at distances larger than 30 cm from the field edge, wedged PD distributions were significantly grater than those for open fields due to increased contribution of leakage radiation. Increased leakage radiation is due to the increase in wedged field monitor units, which is related to a small wedge factor (0.27 to 0.29). PACS number(s): 87.53.–j, 87.66.–a
format Online
Article
Text
id pubmed-5724532
institution National Center for Biotechnology Information
language English
publishDate 2002
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57245322018-04-02 Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge Mutic, Sasa Esthappan, Jacqueline Klein, Eric E. J Appl Clin Med Phys Radiation Oncology Physics The American Association of Physicists in Medicine Task Group 36 (AAPM TG‐36) data can be used to estimate peripheral dose (PD) distributions outside the primary radiation field. However, the report data does not apply to linear accelerators equipped with a multileaf collimator (MLC) and universal wedge (UW). Tertiary multileaf collimators have been shown to significantly affect PD distributions and TG‐36 reported data. Measurements were performed to evaluate PD distributions for a linear accelerator equipped with a secondary MLC, backup diaphragms, and UW. This data can be used to compliment the TG‐36 report for estimation of doses to critical structures outside primary radiation fields. For the evaluated linear accelerator, an MLC is incorporated in the upper secondary collimator jaws. Backup shielding diaphragms are located underneath the MLC. At the nominal collimator position, the MLC and the backup diaphragm provide collimation primarily in the transverse direction. Conventional, solid tungsten‐alloy jaws, located underneath the backup diaphragms, provide secondary collimation in the longitudinal direction. The universal wedge provides dose modulation in the direction of the conventional jaws. Measurements were made with an ionization chamber inserted into a [Formula: see text] water‐equivalent plastic phantom with the secondary collimator and MLC settings of [Formula: see text] , and [Formula: see text] with and without UW. Data was acquired along the machine's longitudinal axis for 6, 10, and 18 MV photons. Peripheral dose distributions were measured with the collimator rotated to 0(°) and 270(°) for open field measurements and to 0(°), 180(°), and 270(°) for wedged fields (IEC 1217). This allowed evaluation of peripheral dose distributions as a function of collimator rotation. Wedged fields were normalized to deliver the same dose at the depth of maximum dose on the central axis as open fields. The measured PD distributions were generally comparable to data reported by TG‐36. At distances close to the field edge (less than 30 or 40 cm), the measured PD distributions were lower when the measurement point was shielded by solid jaws than with MLC and backup diaphragm. At longer distances, this trend reversed for all energies and evaluated field sizes. However, the difference in PD distribution with collimator rotation was not large enough to warrant strategic positioning of the collimator to reduce dose to critical structures outside the primary radiation field. Because internal scatter dominates close to the field edge, wedged PD distributions were comparable to open field doses at distances closer than 30 cm. However, at distances larger than 30 cm from the field edge, wedged PD distributions were significantly grater than those for open fields due to increased contribution of leakage radiation. Increased leakage radiation is due to the increase in wedged field monitor units, which is related to a small wedge factor (0.27 to 0.29). PACS number(s): 87.53.–j, 87.66.–a John Wiley and Sons Inc. 2002-09-01 /pmc/articles/PMC5724532/ /pubmed/12383050 http://dx.doi.org/10.1120/jacmp.v3i4.2554 Text en © 2002 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Mutic, Sasa
Esthappan, Jacqueline
Klein, Eric E.
Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge
title Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge
title_full Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge
title_fullStr Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge
title_full_unstemmed Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge
title_short Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge
title_sort peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724532/
https://www.ncbi.nlm.nih.gov/pubmed/12383050
http://dx.doi.org/10.1120/jacmp.v3i4.2554
work_keys_str_mv AT muticsasa peripheraldosedistributionsforalinearacceleratorequippedwithasecondarymultileafcollimatoranduniversalwedge
AT esthappanjacqueline peripheraldosedistributionsforalinearacceleratorequippedwithasecondarymultileafcollimatoranduniversalwedge
AT kleinerice peripheraldosedistributionsforalinearacceleratorequippedwithasecondarymultileafcollimatoranduniversalwedge