Cargando…
Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method
Monte Carlo calculations of the absorbed dose at various points of a brachytherapy anthropomorphic phantom are presented. The phantom walls and internal structures are made of polymethylmethacrylate and its external shape was taken from a female Alderson phantom. A complete Fletcher‐Green type appli...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2002
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724533/ https://www.ncbi.nlm.nih.gov/pubmed/12383048 http://dx.doi.org/10.1120/jacmp.v3i4.2552 |
_version_ | 1783285378314141696 |
---|---|
author | Rodríguez, Miguel L. deAlmeida, Carlos E. |
author_facet | Rodríguez, Miguel L. deAlmeida, Carlos E. |
author_sort | Rodríguez, Miguel L. |
collection | PubMed |
description | Monte Carlo calculations of the absorbed dose at various points of a brachytherapy anthropomorphic phantom are presented. The phantom walls and internal structures are made of polymethylmethacrylate and its external shape was taken from a female Alderson phantom. A complete Fletcher‐Green type applicator with the uterine tandem was fixed at the bottom of the phantom reproducing a typical geometrical configuration as that attained in a gynecological brachytherapy treatment. The dose rate produced by an array of five (137)Cs CDC‐J type sources placed in the applicator colpostats and the uterine tandem was evaluated by Monte Carlo simulations using the code penelope at three points: point A, the rectum, and the bladder. The influence of the applicator in the dose rate was evaluated by comparing Monte Carlo simulations of the sources alone and the sources inserted in the applicator. Differences up to 56% in the dose may be observed for the two cases in the planes including the rectum and bladder. The results show a reduction of the dose of 15.6%, 14.0%, and 5.6% in the rectum, bladder, and point A respectively, when the applicator wall and shieldings are considered. PACS number(s): 87.53Jw, 87.53.Wz, 87.53.Vb, 87.66.Xa |
format | Online Article Text |
id | pubmed-5724533 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2002 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57245332018-04-02 Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method Rodríguez, Miguel L. deAlmeida, Carlos E. J Appl Clin Med Phys Radiation Oncology Physics Monte Carlo calculations of the absorbed dose at various points of a brachytherapy anthropomorphic phantom are presented. The phantom walls and internal structures are made of polymethylmethacrylate and its external shape was taken from a female Alderson phantom. A complete Fletcher‐Green type applicator with the uterine tandem was fixed at the bottom of the phantom reproducing a typical geometrical configuration as that attained in a gynecological brachytherapy treatment. The dose rate produced by an array of five (137)Cs CDC‐J type sources placed in the applicator colpostats and the uterine tandem was evaluated by Monte Carlo simulations using the code penelope at three points: point A, the rectum, and the bladder. The influence of the applicator in the dose rate was evaluated by comparing Monte Carlo simulations of the sources alone and the sources inserted in the applicator. Differences up to 56% in the dose may be observed for the two cases in the planes including the rectum and bladder. The results show a reduction of the dose of 15.6%, 14.0%, and 5.6% in the rectum, bladder, and point A respectively, when the applicator wall and shieldings are considered. PACS number(s): 87.53Jw, 87.53.Wz, 87.53.Vb, 87.66.Xa John Wiley and Sons Inc. 2002-09-01 /pmc/articles/PMC5724533/ /pubmed/12383048 http://dx.doi.org/10.1120/jacmp.v3i4.2552 Text en © 2002 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Rodríguez, Miguel L. deAlmeida, Carlos E. Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method |
title | Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method |
title_full | Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method |
title_fullStr | Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method |
title_full_unstemmed | Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method |
title_short | Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method |
title_sort | absorbed dose calculations in a brachytherapy pelvic phantom using the monte carlo method |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724533/ https://www.ncbi.nlm.nih.gov/pubmed/12383048 http://dx.doi.org/10.1120/jacmp.v3i4.2552 |
work_keys_str_mv | AT rodriguezmiguell absorbeddosecalculationsinabrachytherapypelvicphantomusingthemontecarlomethod AT dealmeidacarlose absorbeddosecalculationsinabrachytherapypelvicphantomusingthemontecarlomethod |