Cargando…

Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging

Two specially designed plastic/aluminum phantoms positioned thermoluminescent dosimeters (TLDs) at the right and left breast location of an anthrophomorophic chest torso. Imaging was performed on a spiral CT for a volume of the chest phantom through the breast area for a noncontiguous (pitch 1.5) he...

Descripción completa

Detalles Bibliográficos
Autores principales: Hall, Jeffery L., Navarrete, Jorge L., Surprenant, Edgar, Sklansky, Jack, Eisenman, Jack I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2002
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724539/
https://www.ncbi.nlm.nih.gov/pubmed/12383053
http://dx.doi.org/10.1120/jacmp.v3i4.2558
_version_ 1783285379736010752
author Hall, Jeffery L.
Navarrete, Jorge L.
Surprenant, Edgar
Sklansky, Jack
Eisenman, Jack I.
author_facet Hall, Jeffery L.
Navarrete, Jorge L.
Surprenant, Edgar
Sklansky, Jack
Eisenman, Jack I.
author_sort Hall, Jeffery L.
collection PubMed
description Two specially designed plastic/aluminum phantoms positioned thermoluminescent dosimeters (TLDs) at the right and left breast location of an anthrophomorophic chest torso. Imaging was performed on a spiral CT for a volume of the chest phantom through the breast area for a noncontiguous (pitch 1.5) helical chest scan. Conventional pencil beam ionization chamber measurements were made at the same operating parameters. The doses ranged from approximately 1 to 3 cGy. For both breast phantoms, the doses were highest for the medial inner quadrants near the mediastinum. The doses were lowest for the outer quadrants (lateral aspects) of both breasts. PACS number(s): 87.66.–a, 87.52.–g
format Online
Article
Text
id pubmed-5724539
institution National Center for Biotechnology Information
language English
publishDate 2002
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57245392018-04-02 Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging Hall, Jeffery L. Navarrete, Jorge L. Surprenant, Edgar Sklansky, Jack Eisenman, Jack I. J Appl Clin Med Phys Radiation Measurements Two specially designed plastic/aluminum phantoms positioned thermoluminescent dosimeters (TLDs) at the right and left breast location of an anthrophomorophic chest torso. Imaging was performed on a spiral CT for a volume of the chest phantom through the breast area for a noncontiguous (pitch 1.5) helical chest scan. Conventional pencil beam ionization chamber measurements were made at the same operating parameters. The doses ranged from approximately 1 to 3 cGy. For both breast phantoms, the doses were highest for the medial inner quadrants near the mediastinum. The doses were lowest for the outer quadrants (lateral aspects) of both breasts. PACS number(s): 87.66.–a, 87.52.–g John Wiley and Sons Inc. 2002-09-01 /pmc/articles/PMC5724539/ /pubmed/12383053 http://dx.doi.org/10.1120/jacmp.v3i4.2558 Text en © 2002 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Measurements
Hall, Jeffery L.
Navarrete, Jorge L.
Surprenant, Edgar
Sklansky, Jack
Eisenman, Jack I.
Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging
title Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging
title_full Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging
title_fullStr Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging
title_full_unstemmed Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging
title_short Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging
title_sort technical note: a new tld‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral ct chest imaging
topic Radiation Measurements
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724539/
https://www.ncbi.nlm.nih.gov/pubmed/12383053
http://dx.doi.org/10.1120/jacmp.v3i4.2558
work_keys_str_mv AT halljefferyl technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging
AT navarretejorgel technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging
AT surprenantedgar technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging
AT sklanskyjack technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging
AT eisenmanjacki technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging