Cargando…
Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging
Two specially designed plastic/aluminum phantoms positioned thermoluminescent dosimeters (TLDs) at the right and left breast location of an anthrophomorophic chest torso. Imaging was performed on a spiral CT for a volume of the chest phantom through the breast area for a noncontiguous (pitch 1.5) he...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2002
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724539/ https://www.ncbi.nlm.nih.gov/pubmed/12383053 http://dx.doi.org/10.1120/jacmp.v3i4.2558 |
_version_ | 1783285379736010752 |
---|---|
author | Hall, Jeffery L. Navarrete, Jorge L. Surprenant, Edgar Sklansky, Jack Eisenman, Jack I. |
author_facet | Hall, Jeffery L. Navarrete, Jorge L. Surprenant, Edgar Sklansky, Jack Eisenman, Jack I. |
author_sort | Hall, Jeffery L. |
collection | PubMed |
description | Two specially designed plastic/aluminum phantoms positioned thermoluminescent dosimeters (TLDs) at the right and left breast location of an anthrophomorophic chest torso. Imaging was performed on a spiral CT for a volume of the chest phantom through the breast area for a noncontiguous (pitch 1.5) helical chest scan. Conventional pencil beam ionization chamber measurements were made at the same operating parameters. The doses ranged from approximately 1 to 3 cGy. For both breast phantoms, the doses were highest for the medial inner quadrants near the mediastinum. The doses were lowest for the outer quadrants (lateral aspects) of both breasts. PACS number(s): 87.66.–a, 87.52.–g |
format | Online Article Text |
id | pubmed-5724539 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2002 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57245392018-04-02 Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging Hall, Jeffery L. Navarrete, Jorge L. Surprenant, Edgar Sklansky, Jack Eisenman, Jack I. J Appl Clin Med Phys Radiation Measurements Two specially designed plastic/aluminum phantoms positioned thermoluminescent dosimeters (TLDs) at the right and left breast location of an anthrophomorophic chest torso. Imaging was performed on a spiral CT for a volume of the chest phantom through the breast area for a noncontiguous (pitch 1.5) helical chest scan. Conventional pencil beam ionization chamber measurements were made at the same operating parameters. The doses ranged from approximately 1 to 3 cGy. For both breast phantoms, the doses were highest for the medial inner quadrants near the mediastinum. The doses were lowest for the outer quadrants (lateral aspects) of both breasts. PACS number(s): 87.66.–a, 87.52.–g John Wiley and Sons Inc. 2002-09-01 /pmc/articles/PMC5724539/ /pubmed/12383053 http://dx.doi.org/10.1120/jacmp.v3i4.2558 Text en © 2002 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Measurements Hall, Jeffery L. Navarrete, Jorge L. Surprenant, Edgar Sklansky, Jack Eisenman, Jack I. Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging |
title | Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging |
title_full | Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging |
title_fullStr | Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging |
title_full_unstemmed | Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging |
title_short | Technical Note: A new TLD‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral CT chest imaging |
title_sort | technical note: a new tld‐phantom measurement system for determining dose distribution levels in the right and left breast from spiral ct chest imaging |
topic | Radiation Measurements |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724539/ https://www.ncbi.nlm.nih.gov/pubmed/12383053 http://dx.doi.org/10.1120/jacmp.v3i4.2558 |
work_keys_str_mv | AT halljefferyl technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging AT navarretejorgel technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging AT surprenantedgar technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging AT sklanskyjack technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging AT eisenmanjacki technicalnoteanewtldphantommeasurementsystemfordeterminingdosedistributionlevelsintherightandleftbreastfromspiralctchestimaging |