Cargando…
Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study
In the present study, amount of titanium (Ti) released into the surrounding bone during placement of implants with different surface structure was investigated. Quantification of Ti released during insertion from three different implants was performed in this ex vivo study. Jaw bone from pigs was us...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724801/ https://www.ncbi.nlm.nih.gov/pubmed/29242814 http://dx.doi.org/10.1080/23337931.2017.1399270 |
_version_ | 1783285415715799040 |
---|---|
author | Pettersson, Mattias Pettersson, Jean Molin Thorén, Margareta Johansson, Anders |
author_facet | Pettersson, Mattias Pettersson, Jean Molin Thorén, Margareta Johansson, Anders |
author_sort | Pettersson, Mattias |
collection | PubMed |
description | In the present study, amount of titanium (Ti) released into the surrounding bone during placement of implants with different surface structure was investigated. Quantification of Ti released during insertion from three different implants was performed in this ex vivo study. Jaw bone from pigs was used as model for installation of the implants and Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) was used for analysis of the released Ti. Implant surface were examined with scanning electron microscopy (SEM), before and after the placement into the bone. Ti was abraded to the surrounding bone upon insertion of a dental implant and the surface roughness of the implant increased the amount of Ti found. Diameter and total area of the implant were of less importance for the Ti released to the bone. No visible damages to the implant surfaces could be identified in SEM after placement. |
format | Online Article Text |
id | pubmed-5724801 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-57248012017-12-14 Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study Pettersson, Mattias Pettersson, Jean Molin Thorén, Margareta Johansson, Anders Acta Biomater Odontol Scand Original Article In the present study, amount of titanium (Ti) released into the surrounding bone during placement of implants with different surface structure was investigated. Quantification of Ti released during insertion from three different implants was performed in this ex vivo study. Jaw bone from pigs was used as model for installation of the implants and Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) was used for analysis of the released Ti. Implant surface were examined with scanning electron microscopy (SEM), before and after the placement into the bone. Ti was abraded to the surrounding bone upon insertion of a dental implant and the surface roughness of the implant increased the amount of Ti found. Diameter and total area of the implant were of less importance for the Ti released to the bone. No visible damages to the implant surfaces could be identified in SEM after placement. Taylor & Francis 2017-11-14 /pmc/articles/PMC5724801/ /pubmed/29242814 http://dx.doi.org/10.1080/23337931.2017.1399270 Text en © 2017 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Pettersson, Mattias Pettersson, Jean Molin Thorén, Margareta Johansson, Anders Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study |
title | Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study |
title_full | Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study |
title_fullStr | Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study |
title_full_unstemmed | Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study |
title_short | Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study |
title_sort | release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5724801/ https://www.ncbi.nlm.nih.gov/pubmed/29242814 http://dx.doi.org/10.1080/23337931.2017.1399270 |
work_keys_str_mv | AT petterssonmattias releaseoftitaniumafterinsertionofdentalimplantswithdifferentsurfacecharacteristicsanexvivoanimalstudy AT petterssonjean releaseoftitaniumafterinsertionofdentalimplantswithdifferentsurfacecharacteristicsanexvivoanimalstudy AT molinthorenmargareta releaseoftitaniumafterinsertionofdentalimplantswithdifferentsurfacecharacteristicsanexvivoanimalstudy AT johanssonanders releaseoftitaniumafterinsertionofdentalimplantswithdifferentsurfacecharacteristicsanexvivoanimalstudy |