Cargando…
Multiple breath washout testing in adults with pulmonary disease and healthy controls – can fewer measurements eventually be more?
BACKGROUND: Multiple breath washout (MBW) became a valuable research tool assessing ventilation heterogeneity. However, routine clinical application still faces several challenges. Deriving MBW parameters from three technically acceptable measurements according to current recommendations prolongs te...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5725793/ https://www.ncbi.nlm.nih.gov/pubmed/29228942 http://dx.doi.org/10.1186/s12890-017-0543-y |
Sumario: | BACKGROUND: Multiple breath washout (MBW) became a valuable research tool assessing ventilation heterogeneity. However, routine clinical application still faces several challenges. Deriving MBW parameters from three technically acceptable measurements according to current recommendations prolongs test times. We therefore aimed to evaluate reporting only duplicate measurements in healthy adults and pulmonary disease. METHODS: One hundred and fifty-three subjects prospectively underwent conventional lung function testing and closed-circuit SF(6)-MBW. Three technically acceptable MBW-measurements were obtained in 103 subjects. RESULTS: Lung clearance index (LCI) differed significantly among 19 controls (7.4 ± 0.8), 19 patients with sarcoidosis (8.1 ± 1.2), 32 with bronchial asthma (9.2 ± 1.9) and 33 with COPD (10.8 ± 2.2, p < 0.001). Within-test repeatability was high (coefficient of variation between 2.5% in controls and 3.6% in COPD) and remained unchanged when only including the first two measurements. Likewise, LCI remained stable with mean absolute changes ranging from 0.9 ± 0.8% in controls to 1.5 ± 0.9% in COPD (p = 0.1). Mean test time reduction differed significantly between groups reaching 200 s in COPD (p = 0.01). CONCLUSIONS: Duplicate SF(6)-MBW-measurements are sufficient in adult patients with pulmonary disease and healthy controls. LCI values and intra-test repeatability are not affected reducing total test time statistically significant. Our findings have the potential to further facilitate application of MBW in research and clinical routine. TRIAL REGISTRATION: NCT03176745, June 2, 2017 retrospectively registered. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12890-017-0543-y) contains supplementary material, which is available to authorized users. |
---|