Cargando…
b matrix errors in echo planar diffusion tensor imaging
Diffusion‐weighted magnetic resonance imaging (DW‐MRI) is a recognized tool for early detection of infarction of the human brain. DW‐MRI uses the signal loss associated with the random thermal motion of water molecules in the presence of magnetic field gradients to derive parameters that reflect the...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2001
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5726039/ https://www.ncbi.nlm.nih.gov/pubmed/11602015 http://dx.doi.org/10.1120/jacmp.v2i3.2612 |
_version_ | 1783285659003256832 |
---|---|
author | Boujraf, Saïd Luypaert, Robert Osteaux, Michel |
author_facet | Boujraf, Saïd Luypaert, Robert Osteaux, Michel |
author_sort | Boujraf, Saïd |
collection | PubMed |
description | Diffusion‐weighted magnetic resonance imaging (DW‐MRI) is a recognized tool for early detection of infarction of the human brain. DW‐MRI uses the signal loss associated with the random thermal motion of water molecules in the presence of magnetic field gradients to derive parameters that reflect the translational mobility of the water molecules in tissues. If diffusion‐weighted images with different values of b matrix are acquired during one individual investigation, it is possible to calculate apparent diffusion coefficient maps that are the elements of the diffusion tensor. The diffusion tensor elements represent the apparent diffusion coefficient of protons of water molecules in each pixel in the corresponding sample. The relation between signal intensity in the diffusion‐weighted images, diffusion tensor, and b matrix is derived from the Bloch equations. Our goal is to establish the magnitude of the error made in the calculation of the elements of the diffusion tensor when the imaging gradients are ignored. PACS number(s): 87.57. –s, 87.61.–c |
format | Online Article Text |
id | pubmed-5726039 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2001 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57260392018-04-02 b matrix errors in echo planar diffusion tensor imaging Boujraf, Saïd Luypaert, Robert Osteaux, Michel J Appl Clin Med Phys Medical Imaging Diffusion‐weighted magnetic resonance imaging (DW‐MRI) is a recognized tool for early detection of infarction of the human brain. DW‐MRI uses the signal loss associated with the random thermal motion of water molecules in the presence of magnetic field gradients to derive parameters that reflect the translational mobility of the water molecules in tissues. If diffusion‐weighted images with different values of b matrix are acquired during one individual investigation, it is possible to calculate apparent diffusion coefficient maps that are the elements of the diffusion tensor. The diffusion tensor elements represent the apparent diffusion coefficient of protons of water molecules in each pixel in the corresponding sample. The relation between signal intensity in the diffusion‐weighted images, diffusion tensor, and b matrix is derived from the Bloch equations. Our goal is to establish the magnitude of the error made in the calculation of the elements of the diffusion tensor when the imaging gradients are ignored. PACS number(s): 87.57. –s, 87.61.–c John Wiley and Sons Inc. 2001-09-01 /pmc/articles/PMC5726039/ /pubmed/11602015 http://dx.doi.org/10.1120/jacmp.v2i3.2612 Text en © 2001 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Medical Imaging Boujraf, Saïd Luypaert, Robert Osteaux, Michel b matrix errors in echo planar diffusion tensor imaging |
title | b matrix errors in echo planar diffusion tensor imaging |
title_full | b matrix errors in echo planar diffusion tensor imaging |
title_fullStr | b matrix errors in echo planar diffusion tensor imaging |
title_full_unstemmed | b matrix errors in echo planar diffusion tensor imaging |
title_short | b matrix errors in echo planar diffusion tensor imaging |
title_sort | b matrix errors in echo planar diffusion tensor imaging |
topic | Medical Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5726039/ https://www.ncbi.nlm.nih.gov/pubmed/11602015 http://dx.doi.org/10.1120/jacmp.v2i3.2612 |
work_keys_str_mv | AT boujrafsaid bmatrixerrorsinechoplanardiffusiontensorimaging AT luypaertrobert bmatrixerrorsinechoplanardiffusiontensorimaging AT osteauxmichel bmatrixerrorsinechoplanardiffusiontensorimaging |