Use of a radioactive check device for redundancy check of ionization chambers
The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer‐type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionizati...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2000
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5726160/ https://www.ncbi.nlm.nih.gov/pubmed/11674830 http://dx.doi.org/10.1120/jacmp.v1i4.2636 |
_version_ | 1783285686388916224 |
---|---|
author | Sidhu, N. P. S. Rouvas, Alkis Cadman, Patrick |
author_facet | Sidhu, N. P. S. Rouvas, Alkis Cadman, Patrick |
author_sort | Sidhu, N. P. S. |
collection | PubMed |
description | The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer‐type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionization chambers. The ionization chambers exhibited a maximum variation of 1% in the angular response in this check device. After accounting for the angular response the maximum variation of the short‐term repeatability was 0.14% with a standard deviation of [Formula: see text]. The long‐term constancy checked over a period of nine months was less than [Formula: see text] for measurements, taking into account the angular response of the ionization chambers. No significant effect of the background radiation levels was observed on the measurements. PACS number(s): 87.53.–j, 87.52.–g |
format | Online Article Text |
id | pubmed-5726160 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2000 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57261602018-04-02 Use of a radioactive check device for redundancy check of ionization chambers Sidhu, N. P. S. Rouvas, Alkis Cadman, Patrick J Appl Clin Med Phys Radiation Oncology Physics The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer‐type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionization chambers. The ionization chambers exhibited a maximum variation of 1% in the angular response in this check device. After accounting for the angular response the maximum variation of the short‐term repeatability was 0.14% with a standard deviation of [Formula: see text]. The long‐term constancy checked over a period of nine months was less than [Formula: see text] for measurements, taking into account the angular response of the ionization chambers. No significant effect of the background radiation levels was observed on the measurements. PACS number(s): 87.53.–j, 87.52.–g John Wiley and Sons Inc. 2000-09-01 /pmc/articles/PMC5726160/ /pubmed/11674830 http://dx.doi.org/10.1120/jacmp.v1i4.2636 Text en © 2000 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Sidhu, N. P. S. Rouvas, Alkis Cadman, Patrick Use of a radioactive check device for redundancy check of ionization chambers |
title | Use of a radioactive check device for redundancy check of ionization chambers |
title_full | Use of a radioactive check device for redundancy check of ionization chambers |
title_fullStr | Use of a radioactive check device for redundancy check of ionization chambers |
title_full_unstemmed | Use of a radioactive check device for redundancy check of ionization chambers |
title_short | Use of a radioactive check device for redundancy check of ionization chambers |
title_sort | use of a radioactive check device for redundancy check of ionization chambers |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5726160/ https://www.ncbi.nlm.nih.gov/pubmed/11674830 http://dx.doi.org/10.1120/jacmp.v1i4.2636 |
work_keys_str_mv | AT sidhunps useofaradioactivecheckdeviceforredundancycheckofionizationchambers AT rouvasalkis useofaradioactivecheckdeviceforredundancycheckofionizationchambers AT cadmanpatrick useofaradioactivecheckdeviceforredundancycheckofionizationchambers |