Cargando…
Dual-energy micro-CT for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents
Chemical staining of soft-tissues can be used as a strategy to increase their low inherent contrast in X-ray absorption micro-computed tomography (micro-CT), allowing to obtain fast three-dimensional structural information of animal organs. Though some staining agents are commonly used in this conte...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5727238/ https://www.ncbi.nlm.nih.gov/pubmed/29234002 http://dx.doi.org/10.1038/s41598-017-17064-z |
_version_ | 1783285838211186688 |
---|---|
author | Martins de Souza e Silva, Juliana Utsch, Julian Kimm, Melanie A. Allner, Sebastian Epple, Michael F. Achterhold, Klaus Pfeiffer, Franz |
author_facet | Martins de Souza e Silva, Juliana Utsch, Julian Kimm, Melanie A. Allner, Sebastian Epple, Michael F. Achterhold, Klaus Pfeiffer, Franz |
author_sort | Martins de Souza e Silva, Juliana |
collection | PubMed |
description | Chemical staining of soft-tissues can be used as a strategy to increase their low inherent contrast in X-ray absorption micro-computed tomography (micro-CT), allowing to obtain fast three-dimensional structural information of animal organs. Though some staining agents are commonly used in this context, little is known about the staining agents’ ability to stain specific types of tissues; the times necessary to provide a sufficient contrast; and the effect of staining solution in distorting the tissue. Here we contribute to studies of animal organs (mouse heart and lungs) using staining combined with dual-energy micro-CT (DECT). DECT was used in order to obtain an additional quantitative measure for the amount of staining agents within the sample in 3D maps. Our results show that the two staining solutions used in this work diffuse differently in the tissues studied, the staining times of some tens of minutes already produce high-quality micro-CT images and, at the concentrations applied in this work, the staining solutions tested do not cause relevant tissue distortions. While one staining solution provides images of the general morphology of the organs, the other reveals organs’ features in the order of a hundred micrometers. |
format | Online Article Text |
id | pubmed-5727238 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-57272382017-12-13 Dual-energy micro-CT for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents Martins de Souza e Silva, Juliana Utsch, Julian Kimm, Melanie A. Allner, Sebastian Epple, Michael F. Achterhold, Klaus Pfeiffer, Franz Sci Rep Article Chemical staining of soft-tissues can be used as a strategy to increase their low inherent contrast in X-ray absorption micro-computed tomography (micro-CT), allowing to obtain fast three-dimensional structural information of animal organs. Though some staining agents are commonly used in this context, little is known about the staining agents’ ability to stain specific types of tissues; the times necessary to provide a sufficient contrast; and the effect of staining solution in distorting the tissue. Here we contribute to studies of animal organs (mouse heart and lungs) using staining combined with dual-energy micro-CT (DECT). DECT was used in order to obtain an additional quantitative measure for the amount of staining agents within the sample in 3D maps. Our results show that the two staining solutions used in this work diffuse differently in the tissues studied, the staining times of some tens of minutes already produce high-quality micro-CT images and, at the concentrations applied in this work, the staining solutions tested do not cause relevant tissue distortions. While one staining solution provides images of the general morphology of the organs, the other reveals organs’ features in the order of a hundred micrometers. Nature Publishing Group UK 2017-12-12 /pmc/articles/PMC5727238/ /pubmed/29234002 http://dx.doi.org/10.1038/s41598-017-17064-z Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Martins de Souza e Silva, Juliana Utsch, Julian Kimm, Melanie A. Allner, Sebastian Epple, Michael F. Achterhold, Klaus Pfeiffer, Franz Dual-energy micro-CT for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents |
title | Dual-energy micro-CT for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents |
title_full | Dual-energy micro-CT for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents |
title_fullStr | Dual-energy micro-CT for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents |
title_full_unstemmed | Dual-energy micro-CT for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents |
title_short | Dual-energy micro-CT for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents |
title_sort | dual-energy micro-ct for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5727238/ https://www.ncbi.nlm.nih.gov/pubmed/29234002 http://dx.doi.org/10.1038/s41598-017-17064-z |
work_keys_str_mv | AT martinsdesouzaesilvajuliana dualenergymicroctforquantifyingthetimecourseandstainingcharacteristicsofexvivoanimalorganstreatedwithiodineandgadoliniumbasedcontrastagents AT utschjulian dualenergymicroctforquantifyingthetimecourseandstainingcharacteristicsofexvivoanimalorganstreatedwithiodineandgadoliniumbasedcontrastagents AT kimmmelaniea dualenergymicroctforquantifyingthetimecourseandstainingcharacteristicsofexvivoanimalorganstreatedwithiodineandgadoliniumbasedcontrastagents AT allnersebastian dualenergymicroctforquantifyingthetimecourseandstainingcharacteristicsofexvivoanimalorganstreatedwithiodineandgadoliniumbasedcontrastagents AT epplemichaelf dualenergymicroctforquantifyingthetimecourseandstainingcharacteristicsofexvivoanimalorganstreatedwithiodineandgadoliniumbasedcontrastagents AT achterholdklaus dualenergymicroctforquantifyingthetimecourseandstainingcharacteristicsofexvivoanimalorganstreatedwithiodineandgadoliniumbasedcontrastagents AT pfeifferfranz dualenergymicroctforquantifyingthetimecourseandstainingcharacteristicsofexvivoanimalorganstreatedwithiodineandgadoliniumbasedcontrastagents |