Cargando…

Resistant Non-union of Humerus After Intramedullary Nailing Treated with Locking Compression Plate with Bone Grafting With Nail in Situ and Shoulder Spica: A Case Report

INTRODUCTION: Humerus non-union is a challenging situation for the surgeon and devastating and morbid situation for the patient. Surgical approach to the humerus is demanding because of the complex neurovascular anatomy and especially when previous surgeries have been attempted. CASE REPORT: We repo...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Jagdeep, Kalia, Anoop, Khatri, Kavin, Dahuja, Anshul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5728007/
https://www.ncbi.nlm.nih.gov/pubmed/29242802
http://dx.doi.org/10.13107/jocr.2250-0685.906
_version_ 1783285994111369216
author Singh, Jagdeep
Kalia, Anoop
Khatri, Kavin
Dahuja, Anshul
author_facet Singh, Jagdeep
Kalia, Anoop
Khatri, Kavin
Dahuja, Anshul
author_sort Singh, Jagdeep
collection PubMed
description INTRODUCTION: Humerus non-union is a challenging situation for the surgeon and devastating and morbid situation for the patient. Surgical approach to the humerus is demanding because of the complex neurovascular anatomy and especially when previous surgeries have been attempted. CASE REPORT: We report a case of a young adult male who sustained a compound fracture of humerus shaft treated with intramedullary nailing followed by subsequent bone grafting and eventually landed up in non-union and was treated at our center by locking compression plate application with nail in situ with iliac crest autogenous bone graft followed by shoulder spica application. CONCLUSION: Although humerus nailing is a valid therapeutic option for humeral shaft fractures, compression plating is considered the gold standard and non-union secondary to failed interlocking nailing is a challenging situation.
format Online
Article
Text
id pubmed-5728007
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-57280072017-12-14 Resistant Non-union of Humerus After Intramedullary Nailing Treated with Locking Compression Plate with Bone Grafting With Nail in Situ and Shoulder Spica: A Case Report Singh, Jagdeep Kalia, Anoop Khatri, Kavin Dahuja, Anshul J Orthop Case Rep Case Report INTRODUCTION: Humerus non-union is a challenging situation for the surgeon and devastating and morbid situation for the patient. Surgical approach to the humerus is demanding because of the complex neurovascular anatomy and especially when previous surgeries have been attempted. CASE REPORT: We report a case of a young adult male who sustained a compound fracture of humerus shaft treated with intramedullary nailing followed by subsequent bone grafting and eventually landed up in non-union and was treated at our center by locking compression plate application with nail in situ with iliac crest autogenous bone graft followed by shoulder spica application. CONCLUSION: Although humerus nailing is a valid therapeutic option for humeral shaft fractures, compression plating is considered the gold standard and non-union secondary to failed interlocking nailing is a challenging situation. Indian Orthopaedic Research Group 2017 /pmc/articles/PMC5728007/ /pubmed/29242802 http://dx.doi.org/10.13107/jocr.2250-0685.906 Text en Copyright: © Indian Orthopaedic Research Group http://creativecommons.org/licenses/by-nc/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Singh, Jagdeep
Kalia, Anoop
Khatri, Kavin
Dahuja, Anshul
Resistant Non-union of Humerus After Intramedullary Nailing Treated with Locking Compression Plate with Bone Grafting With Nail in Situ and Shoulder Spica: A Case Report
title Resistant Non-union of Humerus After Intramedullary Nailing Treated with Locking Compression Plate with Bone Grafting With Nail in Situ and Shoulder Spica: A Case Report
title_full Resistant Non-union of Humerus After Intramedullary Nailing Treated with Locking Compression Plate with Bone Grafting With Nail in Situ and Shoulder Spica: A Case Report
title_fullStr Resistant Non-union of Humerus After Intramedullary Nailing Treated with Locking Compression Plate with Bone Grafting With Nail in Situ and Shoulder Spica: A Case Report
title_full_unstemmed Resistant Non-union of Humerus After Intramedullary Nailing Treated with Locking Compression Plate with Bone Grafting With Nail in Situ and Shoulder Spica: A Case Report
title_short Resistant Non-union of Humerus After Intramedullary Nailing Treated with Locking Compression Plate with Bone Grafting With Nail in Situ and Shoulder Spica: A Case Report
title_sort resistant non-union of humerus after intramedullary nailing treated with locking compression plate with bone grafting with nail in situ and shoulder spica: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5728007/
https://www.ncbi.nlm.nih.gov/pubmed/29242802
http://dx.doi.org/10.13107/jocr.2250-0685.906
work_keys_str_mv AT singhjagdeep resistantnonunionofhumerusafterintramedullarynailingtreatedwithlockingcompressionplatewithbonegraftingwithnailinsituandshoulderspicaacasereport
AT kaliaanoop resistantnonunionofhumerusafterintramedullarynailingtreatedwithlockingcompressionplatewithbonegraftingwithnailinsituandshoulderspicaacasereport
AT khatrikavin resistantnonunionofhumerusafterintramedullarynailingtreatedwithlockingcompressionplatewithbonegraftingwithnailinsituandshoulderspicaacasereport
AT dahujaanshul resistantnonunionofhumerusafterintramedullarynailingtreatedwithlockingcompressionplatewithbonegraftingwithnailinsituandshoulderspicaacasereport