Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results
PURPOSE: We evaluated long-term clinical and radiographic results in patients underwent primary total hip arthroplasty (THA) using 36-mm metallic femoral head and 1st generation highly cross-linked polyethylene among patients aged 40 years and less, with minimum 10 years follow-up. MATERIALS AND MET...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Hip Society
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5729163/ https://www.ncbi.nlm.nih.gov/pubmed/29250495 http://dx.doi.org/10.5371/hp.2017.29.4.223 |
_version_ | 1783286136441929728 |
---|---|
author | Choi, Won Kee Kim, Jae Jung Cho, Myung-Rae |
author_facet | Choi, Won Kee Kim, Jae Jung Cho, Myung-Rae |
author_sort | Choi, Won Kee |
collection | PubMed |
description | PURPOSE: We evaluated long-term clinical and radiographic results in patients underwent primary total hip arthroplasty (THA) using 36-mm metallic femoral head and 1st generation highly cross-linked polyethylene among patients aged 40 years and less, with minimum 10 years follow-up. MATERIALS AND METHODS: We retrospectively reviewed 20 hips underwent primary THA by one hip surgeon using 36-mm femoral head and 1st generation highly cross-linked polyethylene from 2004 to 2006. Mean follow up was 131.55 months. Clinical follow-ups included functional measurements. And we evaluated post operative complications, prosthesis loosening, failure, and osteolysis. For radiologic evaluations, together with position of acetabular cup at 6 weeks later of postoperation, we separately calculated the penentrations of femoral heads into polyethylene liners during postoperation and one year later check-ups, and during one year later check-ups and final check-ups. Polywear pro3D 5.10 software was used to measure penetrations of femoral head. RESULTS: Mean acetabular cup inclination and anteversion were 49.02° and 10.19°, respectively. Mean thickness of the polyethylene liner at 45° was 6.44 mm. There were no major complications such as implant loosening or osteolysis, and one case of dislocation occurred. Average modified Harris hip score at final follow-up was 91, and Merle d'Aubigne and Postel scores 15 were or over. Average femoral head penetration of bedding wear was 0.170±0.039 mm/year. Steady-state wear rates was 0.059±0.006 mm/year. CONCLUSION: Results of THA with 36-mm metallic femoral heads on 1st generation highly cross linked as a bearing surface in less than 40 year-old patients were satisfactory. |
format | Online Article Text |
id | pubmed-5729163 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Korean Hip Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-57291632017-12-15 Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results Choi, Won Kee Kim, Jae Jung Cho, Myung-Rae Hip Pelvis Original Article PURPOSE: We evaluated long-term clinical and radiographic results in patients underwent primary total hip arthroplasty (THA) using 36-mm metallic femoral head and 1st generation highly cross-linked polyethylene among patients aged 40 years and less, with minimum 10 years follow-up. MATERIALS AND METHODS: We retrospectively reviewed 20 hips underwent primary THA by one hip surgeon using 36-mm femoral head and 1st generation highly cross-linked polyethylene from 2004 to 2006. Mean follow up was 131.55 months. Clinical follow-ups included functional measurements. And we evaluated post operative complications, prosthesis loosening, failure, and osteolysis. For radiologic evaluations, together with position of acetabular cup at 6 weeks later of postoperation, we separately calculated the penentrations of femoral heads into polyethylene liners during postoperation and one year later check-ups, and during one year later check-ups and final check-ups. Polywear pro3D 5.10 software was used to measure penetrations of femoral head. RESULTS: Mean acetabular cup inclination and anteversion were 49.02° and 10.19°, respectively. Mean thickness of the polyethylene liner at 45° was 6.44 mm. There were no major complications such as implant loosening or osteolysis, and one case of dislocation occurred. Average modified Harris hip score at final follow-up was 91, and Merle d'Aubigne and Postel scores 15 were or over. Average femoral head penetration of bedding wear was 0.170±0.039 mm/year. Steady-state wear rates was 0.059±0.006 mm/year. CONCLUSION: Results of THA with 36-mm metallic femoral heads on 1st generation highly cross linked as a bearing surface in less than 40 year-old patients were satisfactory. Korean Hip Society 2017-12 2017-12-01 /pmc/articles/PMC5729163/ /pubmed/29250495 http://dx.doi.org/10.5371/hp.2017.29.4.223 Text en Copyright © 2017 by Korean Hip Society http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Choi, Won Kee Kim, Jae Jung Cho, Myung-Rae Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results |
title | Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results |
title_full | Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results |
title_fullStr | Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results |
title_full_unstemmed | Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results |
title_short | Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results |
title_sort | results of total hip arthroplasty with 36-mm metallic femoral heads on 1st generation highly cross linked polyethylene as a bearing surface in less than forty year-old patients: minimum ten-year results |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5729163/ https://www.ncbi.nlm.nih.gov/pubmed/29250495 http://dx.doi.org/10.5371/hp.2017.29.4.223 |
work_keys_str_mv | AT choiwonkee resultsoftotalhiparthroplastywith36mmmetallicfemoralheadson1stgenerationhighlycrosslinkedpolyethyleneasabearingsurfaceinlessthanfortyyearoldpatientsminimumtenyearresults AT kimjaejung resultsoftotalhiparthroplastywith36mmmetallicfemoralheadson1stgenerationhighlycrosslinkedpolyethyleneasabearingsurfaceinlessthanfortyyearoldpatientsminimumtenyearresults AT chomyungrae resultsoftotalhiparthroplastywith36mmmetallicfemoralheadson1stgenerationhighlycrosslinkedpolyethyleneasabearingsurfaceinlessthanfortyyearoldpatientsminimumtenyearresults |