Cargando…
MDRD vs. CKD-EPI in comparison to (51)Chromium EDTA: a cross sectional study of Malaysian CKD cohort
BACKGROUND: Accurate measurement of renal function is important: however, radiolabelled gold standard measurement of GFR is highly expensive and can only be used on a very limited scale. We aim to compare the performance of Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease-Epid...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5729257/ https://www.ncbi.nlm.nih.gov/pubmed/29237422 http://dx.doi.org/10.1186/s12882-017-0776-2 |
_version_ | 1783286156584026112 |
---|---|
author | Jalalonmuhali, Maisarah Lim, Soo Kun Md Shah, Mohammad Nazri Ng, Kok Peng |
author_facet | Jalalonmuhali, Maisarah Lim, Soo Kun Md Shah, Mohammad Nazri Ng, Kok Peng |
author_sort | Jalalonmuhali, Maisarah |
collection | PubMed |
description | BACKGROUND: Accurate measurement of renal function is important: however, radiolabelled gold standard measurement of GFR is highly expensive and can only be used on a very limited scale. We aim to compare the performance of Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) equations in the multi-ethnic population attending University Malaya Medical Centre (UMMC). METHODS: This is a cross-sectional study recruiting patients, who attend UMMC Nephrology clinics on voluntary basis. 51-Chromium EDTA ((51)Cr-EDTA) plasma level was used to measure the reference GFR. The serum creatinine was determined by IDMS reference modified Jaffe kinetic assay (Cr(Jaffe)). The predictive capabilities of MDRD and CKD-EPI based equations were calculated. Data was analysed using SPSS version 20 and correlation, bias, precision and accuracy were determined. RESULTS: A total of 113 subjects with mean age of 58.12 ± 14.76 years and BMI of 25.99 ± 4.29 kg/m(2) were recruited. The mean reference GFR was 66.98 ± 40.65 ml/min/1.73m(2), while the estimated GFR based on MDRD and CKD-EPI formula were 62.17 ± 40.40, and 60.44 ± 34.59, respectively. Both MDRD and CKD-EPI were well-correlated with reference GFR (0.806 and 0.867 respectively) and statistically significant with p < 0.001. In the overall cohort, although MDRD had smaller bias than CKD-EPI (4.81 vs. 6.54), CKD-EPI was more precise (25.22 vs. 20.29) with higher accuracy within 30% of measured GFR (79.65 vs. 86.73%). CONCLUSION: The CKD-EPI equation appeared to be more precise and accurate than the MDRD equation in estimating GFR in our cohort of multi-ethnic populations in Malaysia. |
format | Online Article Text |
id | pubmed-5729257 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-57292572017-12-18 MDRD vs. CKD-EPI in comparison to (51)Chromium EDTA: a cross sectional study of Malaysian CKD cohort Jalalonmuhali, Maisarah Lim, Soo Kun Md Shah, Mohammad Nazri Ng, Kok Peng BMC Nephrol Research Article BACKGROUND: Accurate measurement of renal function is important: however, radiolabelled gold standard measurement of GFR is highly expensive and can only be used on a very limited scale. We aim to compare the performance of Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) equations in the multi-ethnic population attending University Malaya Medical Centre (UMMC). METHODS: This is a cross-sectional study recruiting patients, who attend UMMC Nephrology clinics on voluntary basis. 51-Chromium EDTA ((51)Cr-EDTA) plasma level was used to measure the reference GFR. The serum creatinine was determined by IDMS reference modified Jaffe kinetic assay (Cr(Jaffe)). The predictive capabilities of MDRD and CKD-EPI based equations were calculated. Data was analysed using SPSS version 20 and correlation, bias, precision and accuracy were determined. RESULTS: A total of 113 subjects with mean age of 58.12 ± 14.76 years and BMI of 25.99 ± 4.29 kg/m(2) were recruited. The mean reference GFR was 66.98 ± 40.65 ml/min/1.73m(2), while the estimated GFR based on MDRD and CKD-EPI formula were 62.17 ± 40.40, and 60.44 ± 34.59, respectively. Both MDRD and CKD-EPI were well-correlated with reference GFR (0.806 and 0.867 respectively) and statistically significant with p < 0.001. In the overall cohort, although MDRD had smaller bias than CKD-EPI (4.81 vs. 6.54), CKD-EPI was more precise (25.22 vs. 20.29) with higher accuracy within 30% of measured GFR (79.65 vs. 86.73%). CONCLUSION: The CKD-EPI equation appeared to be more precise and accurate than the MDRD equation in estimating GFR in our cohort of multi-ethnic populations in Malaysia. BioMed Central 2017-12-13 /pmc/articles/PMC5729257/ /pubmed/29237422 http://dx.doi.org/10.1186/s12882-017-0776-2 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Jalalonmuhali, Maisarah Lim, Soo Kun Md Shah, Mohammad Nazri Ng, Kok Peng MDRD vs. CKD-EPI in comparison to (51)Chromium EDTA: a cross sectional study of Malaysian CKD cohort |
title | MDRD vs. CKD-EPI in comparison to (51)Chromium EDTA: a cross sectional study of Malaysian CKD cohort |
title_full | MDRD vs. CKD-EPI in comparison to (51)Chromium EDTA: a cross sectional study of Malaysian CKD cohort |
title_fullStr | MDRD vs. CKD-EPI in comparison to (51)Chromium EDTA: a cross sectional study of Malaysian CKD cohort |
title_full_unstemmed | MDRD vs. CKD-EPI in comparison to (51)Chromium EDTA: a cross sectional study of Malaysian CKD cohort |
title_short | MDRD vs. CKD-EPI in comparison to (51)Chromium EDTA: a cross sectional study of Malaysian CKD cohort |
title_sort | mdrd vs. ckd-epi in comparison to (51)chromium edta: a cross sectional study of malaysian ckd cohort |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5729257/ https://www.ncbi.nlm.nih.gov/pubmed/29237422 http://dx.doi.org/10.1186/s12882-017-0776-2 |
work_keys_str_mv | AT jalalonmuhalimaisarah mdrdvsckdepiincomparisonto51chromiumedtaacrosssectionalstudyofmalaysianckdcohort AT limsookun mdrdvsckdepiincomparisonto51chromiumedtaacrosssectionalstudyofmalaysianckdcohort AT mdshahmohammadnazri mdrdvsckdepiincomparisonto51chromiumedtaacrosssectionalstudyofmalaysianckdcohort AT ngkokpeng mdrdvsckdepiincomparisonto51chromiumedtaacrosssectionalstudyofmalaysianckdcohort |