Cargando…
Resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report
BACKGROUND: The resuscitative endovascular balloon occlusion of the aorta, because of its efficacy and feasibility, has been widely used in treating patients with severe torso trauma. However, complications developing around the site proximal to the occlusion by resuscitative endovascular balloon oc...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5729271/ https://www.ncbi.nlm.nih.gov/pubmed/29237485 http://dx.doi.org/10.1186/s13256-017-1511-0 |
_version_ | 1783286160017063936 |
---|---|
author | Maruhashi, Takaaki Minehara, Hiroaki Takeuchi, Ichiro Kataoka, Yuichi Asari, Yasushi |
author_facet | Maruhashi, Takaaki Minehara, Hiroaki Takeuchi, Ichiro Kataoka, Yuichi Asari, Yasushi |
author_sort | Maruhashi, Takaaki |
collection | PubMed |
description | BACKGROUND: The resuscitative endovascular balloon occlusion of the aorta, because of its efficacy and feasibility, has been widely used in treating patients with severe torso trauma. However, complications developing around the site proximal to the occlusion by resuscitative endovascular balloon occlusion of the aorta have almost never been studied. CASE PRESENTATION: A 50-year-old Japanese woman fell from a height of approximately 10 m. At initial arrival, her respiratory rate was 24 breaths/minute, her blood oxygen saturation was 95% under 10 L/minute oxygenation, her pulse rate was 90 beats per minute, and her blood pressure was 180/120 mmHg. Mild lung contusion, hemopneumothorax, unstable pelvic fracture, and retroperitoneal bleeding with extravasation of contrast media were observed in initial computed tomography. As her vital signs had deteriorated during computed tomography, a 7-French aortic occlusion catheter (RESCUE BALLOON®, Tokai Medical Products, Aichi, Japan) was inserted and inflated for aortic occlusion at the first lumbar vertebra level and transcatheter arterial embolization was performed for the pelvic fracture. Her bilateral internal iliac arteries were embolized with a gelatin sponge; however, the embolized sites presented recanalization as coagulopathy appeared. Her bilateral internal iliac arteries were re-embolized by n-butyl-2-cyanoacrylate. The balloon was deflated 18 minutes later. After embolization, repeat computed tomography was performed and a massive hemothorax, which had not been captured on arrival, had appeared in her left pleural cavity. Thoracotomy hemostasis was performed and a hemothorax of approximately 2500 ml was aspirated to search for the source of bleeding. However, clear active bleeding was not captured; resuscitative endovascular balloon occlusion of the aorta may have been the cause of the increased bleeding of the thoracic injury at the proximal site of the aorta occlusion. CONCLUSIONS: It is necessary to note that the use of resuscitative endovascular balloon occlusion of the aorta may increase bleeding in sites proximal to occlusions, even in the case of minor injuries without active bleeding at the initial diagnosis. |
format | Online Article Text |
id | pubmed-5729271 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-57292712017-12-18 Resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report Maruhashi, Takaaki Minehara, Hiroaki Takeuchi, Ichiro Kataoka, Yuichi Asari, Yasushi J Med Case Rep Case Report BACKGROUND: The resuscitative endovascular balloon occlusion of the aorta, because of its efficacy and feasibility, has been widely used in treating patients with severe torso trauma. However, complications developing around the site proximal to the occlusion by resuscitative endovascular balloon occlusion of the aorta have almost never been studied. CASE PRESENTATION: A 50-year-old Japanese woman fell from a height of approximately 10 m. At initial arrival, her respiratory rate was 24 breaths/minute, her blood oxygen saturation was 95% under 10 L/minute oxygenation, her pulse rate was 90 beats per minute, and her blood pressure was 180/120 mmHg. Mild lung contusion, hemopneumothorax, unstable pelvic fracture, and retroperitoneal bleeding with extravasation of contrast media were observed in initial computed tomography. As her vital signs had deteriorated during computed tomography, a 7-French aortic occlusion catheter (RESCUE BALLOON®, Tokai Medical Products, Aichi, Japan) was inserted and inflated for aortic occlusion at the first lumbar vertebra level and transcatheter arterial embolization was performed for the pelvic fracture. Her bilateral internal iliac arteries were embolized with a gelatin sponge; however, the embolized sites presented recanalization as coagulopathy appeared. Her bilateral internal iliac arteries were re-embolized by n-butyl-2-cyanoacrylate. The balloon was deflated 18 minutes later. After embolization, repeat computed tomography was performed and a massive hemothorax, which had not been captured on arrival, had appeared in her left pleural cavity. Thoracotomy hemostasis was performed and a hemothorax of approximately 2500 ml was aspirated to search for the source of bleeding. However, clear active bleeding was not captured; resuscitative endovascular balloon occlusion of the aorta may have been the cause of the increased bleeding of the thoracic injury at the proximal site of the aorta occlusion. CONCLUSIONS: It is necessary to note that the use of resuscitative endovascular balloon occlusion of the aorta may increase bleeding in sites proximal to occlusions, even in the case of minor injuries without active bleeding at the initial diagnosis. BioMed Central 2017-12-14 /pmc/articles/PMC5729271/ /pubmed/29237485 http://dx.doi.org/10.1186/s13256-017-1511-0 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Case Report Maruhashi, Takaaki Minehara, Hiroaki Takeuchi, Ichiro Kataoka, Yuichi Asari, Yasushi Resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report |
title | Resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report |
title_full | Resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report |
title_fullStr | Resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report |
title_full_unstemmed | Resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report |
title_short | Resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report |
title_sort | resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5729271/ https://www.ncbi.nlm.nih.gov/pubmed/29237485 http://dx.doi.org/10.1186/s13256-017-1511-0 |
work_keys_str_mv | AT maruhashitakaaki resuscitativeendovascularballoonocclusionoftheaortamayincreasethebleedingofminorthoracicinjuryinseveremultipletraumapatientsacasereport AT mineharahiroaki resuscitativeendovascularballoonocclusionoftheaortamayincreasethebleedingofminorthoracicinjuryinseveremultipletraumapatientsacasereport AT takeuchiichiro resuscitativeendovascularballoonocclusionoftheaortamayincreasethebleedingofminorthoracicinjuryinseveremultipletraumapatientsacasereport AT kataokayuichi resuscitativeendovascularballoonocclusionoftheaortamayincreasethebleedingofminorthoracicinjuryinseveremultipletraumapatientsacasereport AT asariyasushi resuscitativeendovascularballoonocclusionoftheaortamayincreasethebleedingofminorthoracicinjuryinseveremultipletraumapatientsacasereport |