Cargando…

Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach

OBJECTIVE: The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction...

Descripción completa

Detalles Bibliográficos
Autor principal: Felicita, A. Sumathi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dental Press International 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5730136/
https://www.ncbi.nlm.nih.gov/pubmed/29160344
http://dx.doi.org/10.1590/2177-6709.22.5.047-055.oar
_version_ 1783286302698897408
author Felicita, A. Sumathi
author_facet Felicita, A. Sumathi
author_sort Felicita, A. Sumathi
collection PubMed
description OBJECTIVE: The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction using mini-implants. METHODS: The optimum force required for en-masse intrusion and retraction can be calculated by using simple mathematical formulae. Depending on the position of the mini-implant and the relationship of the attachment to the center of resistance of the anterior segment, different clinical outcomes are encountered. Using certain mathematical formulae, accurate measurements of the magnitude of force and moment generated on the teeth can be calculated for each clinical outcome. RESULTS: Optimum force for en-masse intrusion and retraction of maxillary anterior teeth is 212 grams per side. Force applied at an angle of 5(o) to 16(o) from the occlusal plane produce intrusive and retraction force components that are within the physiologic limit. CONCLUSION: Different clinical outcomes are encountered depending on the position of the mini-implant and the length of the attachment. It is possible to calculate the forces and moments generated for any given magnitude of applied force. The orthodontist can apply the basic biomechanical principles mentioned in this study to calculate the forces and moments for different hypothetical clinical scenarios.
format Online
Article
Text
id pubmed-5730136
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Dental Press International
record_format MEDLINE/PubMed
spelling pubmed-57301362017-12-18 Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach Felicita, A. Sumathi Dental Press J Orthod Original Article OBJECTIVE: The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction using mini-implants. METHODS: The optimum force required for en-masse intrusion and retraction can be calculated by using simple mathematical formulae. Depending on the position of the mini-implant and the relationship of the attachment to the center of resistance of the anterior segment, different clinical outcomes are encountered. Using certain mathematical formulae, accurate measurements of the magnitude of force and moment generated on the teeth can be calculated for each clinical outcome. RESULTS: Optimum force for en-masse intrusion and retraction of maxillary anterior teeth is 212 grams per side. Force applied at an angle of 5(o) to 16(o) from the occlusal plane produce intrusive and retraction force components that are within the physiologic limit. CONCLUSION: Different clinical outcomes are encountered depending on the position of the mini-implant and the length of the attachment. It is possible to calculate the forces and moments generated for any given magnitude of applied force. The orthodontist can apply the basic biomechanical principles mentioned in this study to calculate the forces and moments for different hypothetical clinical scenarios. Dental Press International 2017 /pmc/articles/PMC5730136/ /pubmed/29160344 http://dx.doi.org/10.1590/2177-6709.22.5.047-055.oar Text en http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Original Article
Felicita, A. Sumathi
Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach
title Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach
title_full Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach
title_fullStr Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach
title_full_unstemmed Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach
title_short Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach
title_sort quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: a conceptual approach
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5730136/
https://www.ncbi.nlm.nih.gov/pubmed/29160344
http://dx.doi.org/10.1590/2177-6709.22.5.047-055.oar
work_keys_str_mv AT felicitaasumathi quantificationofintrusiveretractionforceandmomentgeneratedduringenmasseretractionofmaxillaryanteriorteethusingminiimplantsaconceptualapproach