Cargando…

Imaging the human placental microcirculation with micro-focus computed tomography: Optimisation of tissue preparation and image acquisition

Micro-CT provides 3D volume imaging with spatial resolution at the micrometre scale. We investigated the optimal human placenta tissue preparation (contrast agent, perfusion pressure, perfusion location and perfusion vessel) and imaging (energy, target material, exposure time and frames) parameters....

Descripción completa

Detalles Bibliográficos
Autores principales: Pratt, Rosalind, Hutchinson, J. Ciaran, Melbourne, Andrew, Zuluaga, Maria A., Virasami, Alex, Vercauteren, Tom, Ourselin, Sebastien, Sebire, Neil J., Arthurs, Owen J., David, Anna L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5730539/
https://www.ncbi.nlm.nih.gov/pubmed/29208237
http://dx.doi.org/10.1016/j.placenta.2017.09.013
_version_ 1783286359862018048
author Pratt, Rosalind
Hutchinson, J. Ciaran
Melbourne, Andrew
Zuluaga, Maria A.
Virasami, Alex
Vercauteren, Tom
Ourselin, Sebastien
Sebire, Neil J.
Arthurs, Owen J.
David, Anna L.
author_facet Pratt, Rosalind
Hutchinson, J. Ciaran
Melbourne, Andrew
Zuluaga, Maria A.
Virasami, Alex
Vercauteren, Tom
Ourselin, Sebastien
Sebire, Neil J.
Arthurs, Owen J.
David, Anna L.
author_sort Pratt, Rosalind
collection PubMed
description Micro-CT provides 3D volume imaging with spatial resolution at the micrometre scale. We investigated the optimal human placenta tissue preparation (contrast agent, perfusion pressure, perfusion location and perfusion vessel) and imaging (energy, target material, exposure time and frames) parameters. Microfil (Flow Tech, Carver, MA) produced better fill than Barium sulphate (84.1%(±11.5%)vs70.4%(±18.02%) p = 0.01). Perfusion via umbilical artery produced better fill than via chorionic vessels (83.8%(±17.7%)vs78.0%(±21.9%), p < 0.05), or via umbilical vein (83.8%(±16.4%)vs69.8%(±20.3%), p < 0.01). Imaging at 50 keV with a molybdenum target produced the best contrast to noise ratio. We propose this method to enable quantification and comparison of the human fetoplacental vascular tree.
format Online
Article
Text
id pubmed-5730539
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-57305392017-12-22 Imaging the human placental microcirculation with micro-focus computed tomography: Optimisation of tissue preparation and image acquisition Pratt, Rosalind Hutchinson, J. Ciaran Melbourne, Andrew Zuluaga, Maria A. Virasami, Alex Vercauteren, Tom Ourselin, Sebastien Sebire, Neil J. Arthurs, Owen J. David, Anna L. Placenta Article Micro-CT provides 3D volume imaging with spatial resolution at the micrometre scale. We investigated the optimal human placenta tissue preparation (contrast agent, perfusion pressure, perfusion location and perfusion vessel) and imaging (energy, target material, exposure time and frames) parameters. Microfil (Flow Tech, Carver, MA) produced better fill than Barium sulphate (84.1%(±11.5%)vs70.4%(±18.02%) p = 0.01). Perfusion via umbilical artery produced better fill than via chorionic vessels (83.8%(±17.7%)vs78.0%(±21.9%), p < 0.05), or via umbilical vein (83.8%(±16.4%)vs69.8%(±20.3%), p < 0.01). Imaging at 50 keV with a molybdenum target produced the best contrast to noise ratio. We propose this method to enable quantification and comparison of the human fetoplacental vascular tree. Elsevier 2017-12 /pmc/articles/PMC5730539/ /pubmed/29208237 http://dx.doi.org/10.1016/j.placenta.2017.09.013 Text en © 2017 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pratt, Rosalind
Hutchinson, J. Ciaran
Melbourne, Andrew
Zuluaga, Maria A.
Virasami, Alex
Vercauteren, Tom
Ourselin, Sebastien
Sebire, Neil J.
Arthurs, Owen J.
David, Anna L.
Imaging the human placental microcirculation with micro-focus computed tomography: Optimisation of tissue preparation and image acquisition
title Imaging the human placental microcirculation with micro-focus computed tomography: Optimisation of tissue preparation and image acquisition
title_full Imaging the human placental microcirculation with micro-focus computed tomography: Optimisation of tissue preparation and image acquisition
title_fullStr Imaging the human placental microcirculation with micro-focus computed tomography: Optimisation of tissue preparation and image acquisition
title_full_unstemmed Imaging the human placental microcirculation with micro-focus computed tomography: Optimisation of tissue preparation and image acquisition
title_short Imaging the human placental microcirculation with micro-focus computed tomography: Optimisation of tissue preparation and image acquisition
title_sort imaging the human placental microcirculation with micro-focus computed tomography: optimisation of tissue preparation and image acquisition
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5730539/
https://www.ncbi.nlm.nih.gov/pubmed/29208237
http://dx.doi.org/10.1016/j.placenta.2017.09.013
work_keys_str_mv AT prattrosalind imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition
AT hutchinsonjciaran imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition
AT melbourneandrew imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition
AT zuluagamariaa imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition
AT virasamialex imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition
AT vercauterentom imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition
AT ourselinsebastien imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition
AT sebireneilj imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition
AT arthursowenj imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition
AT davidannal imagingthehumanplacentalmicrocirculationwithmicrofocuscomputedtomographyoptimisationoftissuepreparationandimageacquisition