Cargando…

Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study

BACKGROUND AND OBJECTIVES: This in vitro study seeks to evaluate and compare the marginal and internal fit of cobalt-chromium copings fabricated using the conventional and direct metal laser sintering (DMLS) techniques. METHODS: A master model of a prepared molar tooth was made using cobalt-chromium...

Descripción completa

Detalles Bibliográficos
Autores principales: Ullattuthodi, Sujana, Cherian, Kandathil Phillip, Anandkumar, R., Nambiar, M. Sreedevi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5730929/
https://www.ncbi.nlm.nih.gov/pubmed/29249881
http://dx.doi.org/10.4103/jips.jips_88_17
_version_ 1783286434016264192
author Ullattuthodi, Sujana
Cherian, Kandathil Phillip
Anandkumar, R.
Nambiar, M. Sreedevi
author_facet Ullattuthodi, Sujana
Cherian, Kandathil Phillip
Anandkumar, R.
Nambiar, M. Sreedevi
author_sort Ullattuthodi, Sujana
collection PubMed
description BACKGROUND AND OBJECTIVES: This in vitro study seeks to evaluate and compare the marginal and internal fit of cobalt-chromium copings fabricated using the conventional and direct metal laser sintering (DMLS) techniques. METHODS: A master model of a prepared molar tooth was made using cobalt-chromium alloy. Silicone impression of the master model was made and thirty standardized working models were then produced; twenty working models for conventional lost-wax technique and ten working models for DMLS technique. A total of twenty metal copings were fabricated using two different production techniques: conventional lost-wax method and DMLS; ten samples in each group. The conventional and DMLS copings were cemented to the working models using glass ionomer cement. Marginal gap of the copings were measured at predetermined four points. The die with the cemented copings are standardized-sectioned with a heavy duty lathe. Then, each sectioned samples were analyzed for the internal gap between the die and the metal coping using a metallurgical microscope. Digital photographs were taken at ×50 magnification and analyzed using measurement software. Statistical analysis was done by unpaired t-test and analysis of variance (ANOVA). RESULTS: The results of this study reveal that no significant difference was present in the marginal gap of conventional and DMLS copings (P > 0.05) by means of ANOVA. The mean values of internal gap of DMLS copings were significantly greater than that of conventional copings (P < 0.05). CONCLUSIONS: Within the limitations of this in vitro study, it was concluded that the internal fit of conventional copings was superior to that of the DMLS copings. Marginal fit of the copings fabricated by two different techniques had no significant difference.
format Online
Article
Text
id pubmed-5730929
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-57309292018-10-01 Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study Ullattuthodi, Sujana Cherian, Kandathil Phillip Anandkumar, R. Nambiar, M. Sreedevi J Indian Prosthodont Soc Original Article BACKGROUND AND OBJECTIVES: This in vitro study seeks to evaluate and compare the marginal and internal fit of cobalt-chromium copings fabricated using the conventional and direct metal laser sintering (DMLS) techniques. METHODS: A master model of a prepared molar tooth was made using cobalt-chromium alloy. Silicone impression of the master model was made and thirty standardized working models were then produced; twenty working models for conventional lost-wax technique and ten working models for DMLS technique. A total of twenty metal copings were fabricated using two different production techniques: conventional lost-wax method and DMLS; ten samples in each group. The conventional and DMLS copings were cemented to the working models using glass ionomer cement. Marginal gap of the copings were measured at predetermined four points. The die with the cemented copings are standardized-sectioned with a heavy duty lathe. Then, each sectioned samples were analyzed for the internal gap between the die and the metal coping using a metallurgical microscope. Digital photographs were taken at ×50 magnification and analyzed using measurement software. Statistical analysis was done by unpaired t-test and analysis of variance (ANOVA). RESULTS: The results of this study reveal that no significant difference was present in the marginal gap of conventional and DMLS copings (P > 0.05) by means of ANOVA. The mean values of internal gap of DMLS copings were significantly greater than that of conventional copings (P < 0.05). CONCLUSIONS: Within the limitations of this in vitro study, it was concluded that the internal fit of conventional copings was superior to that of the DMLS copings. Marginal fit of the copings fabricated by two different techniques had no significant difference. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5730929/ /pubmed/29249881 http://dx.doi.org/10.4103/jips.jips_88_17 Text en Copyright: © 2017 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ullattuthodi, Sujana
Cherian, Kandathil Phillip
Anandkumar, R.
Nambiar, M. Sreedevi
Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study
title Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study
title_full Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study
title_fullStr Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study
title_full_unstemmed Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study
title_short Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study
title_sort marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: a comparative in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5730929/
https://www.ncbi.nlm.nih.gov/pubmed/29249881
http://dx.doi.org/10.4103/jips.jips_88_17
work_keys_str_mv AT ullattuthodisujana marginalandinternalfitofcobaltchromiumcopingsfabricatedusingtheconventionalandthedirectmetallasersinteringtechniquesacomparativeinvitrostudy
AT cheriankandathilphillip marginalandinternalfitofcobaltchromiumcopingsfabricatedusingtheconventionalandthedirectmetallasersinteringtechniquesacomparativeinvitrostudy
AT anandkumarr marginalandinternalfitofcobaltchromiumcopingsfabricatedusingtheconventionalandthedirectmetallasersinteringtechniquesacomparativeinvitrostudy
AT nambiarmsreedevi marginalandinternalfitofcobaltchromiumcopingsfabricatedusingtheconventionalandthedirectmetallasersinteringtechniquesacomparativeinvitrostudy