Cargando…
Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study
BACKGROUND AND OBJECTIVES: This in vitro study seeks to evaluate and compare the marginal and internal fit of cobalt-chromium copings fabricated using the conventional and direct metal laser sintering (DMLS) techniques. METHODS: A master model of a prepared molar tooth was made using cobalt-chromium...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5730929/ https://www.ncbi.nlm.nih.gov/pubmed/29249881 http://dx.doi.org/10.4103/jips.jips_88_17 |
_version_ | 1783286434016264192 |
---|---|
author | Ullattuthodi, Sujana Cherian, Kandathil Phillip Anandkumar, R. Nambiar, M. Sreedevi |
author_facet | Ullattuthodi, Sujana Cherian, Kandathil Phillip Anandkumar, R. Nambiar, M. Sreedevi |
author_sort | Ullattuthodi, Sujana |
collection | PubMed |
description | BACKGROUND AND OBJECTIVES: This in vitro study seeks to evaluate and compare the marginal and internal fit of cobalt-chromium copings fabricated using the conventional and direct metal laser sintering (DMLS) techniques. METHODS: A master model of a prepared molar tooth was made using cobalt-chromium alloy. Silicone impression of the master model was made and thirty standardized working models were then produced; twenty working models for conventional lost-wax technique and ten working models for DMLS technique. A total of twenty metal copings were fabricated using two different production techniques: conventional lost-wax method and DMLS; ten samples in each group. The conventional and DMLS copings were cemented to the working models using glass ionomer cement. Marginal gap of the copings were measured at predetermined four points. The die with the cemented copings are standardized-sectioned with a heavy duty lathe. Then, each sectioned samples were analyzed for the internal gap between the die and the metal coping using a metallurgical microscope. Digital photographs were taken at ×50 magnification and analyzed using measurement software. Statistical analysis was done by unpaired t-test and analysis of variance (ANOVA). RESULTS: The results of this study reveal that no significant difference was present in the marginal gap of conventional and DMLS copings (P > 0.05) by means of ANOVA. The mean values of internal gap of DMLS copings were significantly greater than that of conventional copings (P < 0.05). CONCLUSIONS: Within the limitations of this in vitro study, it was concluded that the internal fit of conventional copings was superior to that of the DMLS copings. Marginal fit of the copings fabricated by two different techniques had no significant difference. |
format | Online Article Text |
id | pubmed-5730929 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-57309292018-10-01 Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study Ullattuthodi, Sujana Cherian, Kandathil Phillip Anandkumar, R. Nambiar, M. Sreedevi J Indian Prosthodont Soc Original Article BACKGROUND AND OBJECTIVES: This in vitro study seeks to evaluate and compare the marginal and internal fit of cobalt-chromium copings fabricated using the conventional and direct metal laser sintering (DMLS) techniques. METHODS: A master model of a prepared molar tooth was made using cobalt-chromium alloy. Silicone impression of the master model was made and thirty standardized working models were then produced; twenty working models for conventional lost-wax technique and ten working models for DMLS technique. A total of twenty metal copings were fabricated using two different production techniques: conventional lost-wax method and DMLS; ten samples in each group. The conventional and DMLS copings were cemented to the working models using glass ionomer cement. Marginal gap of the copings were measured at predetermined four points. The die with the cemented copings are standardized-sectioned with a heavy duty lathe. Then, each sectioned samples were analyzed for the internal gap between the die and the metal coping using a metallurgical microscope. Digital photographs were taken at ×50 magnification and analyzed using measurement software. Statistical analysis was done by unpaired t-test and analysis of variance (ANOVA). RESULTS: The results of this study reveal that no significant difference was present in the marginal gap of conventional and DMLS copings (P > 0.05) by means of ANOVA. The mean values of internal gap of DMLS copings were significantly greater than that of conventional copings (P < 0.05). CONCLUSIONS: Within the limitations of this in vitro study, it was concluded that the internal fit of conventional copings was superior to that of the DMLS copings. Marginal fit of the copings fabricated by two different techniques had no significant difference. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5730929/ /pubmed/29249881 http://dx.doi.org/10.4103/jips.jips_88_17 Text en Copyright: © 2017 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Ullattuthodi, Sujana Cherian, Kandathil Phillip Anandkumar, R. Nambiar, M. Sreedevi Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study |
title | Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study |
title_full | Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study |
title_fullStr | Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study |
title_full_unstemmed | Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study |
title_short | Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study |
title_sort | marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: a comparative in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5730929/ https://www.ncbi.nlm.nih.gov/pubmed/29249881 http://dx.doi.org/10.4103/jips.jips_88_17 |
work_keys_str_mv | AT ullattuthodisujana marginalandinternalfitofcobaltchromiumcopingsfabricatedusingtheconventionalandthedirectmetallasersinteringtechniquesacomparativeinvitrostudy AT cheriankandathilphillip marginalandinternalfitofcobaltchromiumcopingsfabricatedusingtheconventionalandthedirectmetallasersinteringtechniquesacomparativeinvitrostudy AT anandkumarr marginalandinternalfitofcobaltchromiumcopingsfabricatedusingtheconventionalandthedirectmetallasersinteringtechniquesacomparativeinvitrostudy AT nambiarmsreedevi marginalandinternalfitofcobaltchromiumcopingsfabricatedusingtheconventionalandthedirectmetallasersinteringtechniquesacomparativeinvitrostudy |