Cargando…

Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity

INTRODUCTION: With arthroscopic techniques being used, the importance of knot tying has been examined. Previous literature has examined the use of reversing half-hitches on alternating posts (RHAPs) on knot security. Separately, there has been research regarding different suture materials commonly u...

Descripción completa

Detalles Bibliográficos
Autores principales: Chong, Alexander CM., Prohaska, Daniel J., Bye, Brian P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: University of Kansas Medical Center 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5733413/
https://www.ncbi.nlm.nih.gov/pubmed/29472965
_version_ 1783286893882900480
author Chong, Alexander CM.
Prohaska, Daniel J.
Bye, Brian P.
author_facet Chong, Alexander CM.
Prohaska, Daniel J.
Bye, Brian P.
author_sort Chong, Alexander CM.
collection PubMed
description INTRODUCTION: With arthroscopic techniques being used, the importance of knot tying has been examined. Previous literature has examined the use of reversing half-hitches on alternating posts (RHAPs) on knot security. Separately, there has been research regarding different suture materials commonly used in the operating room. The specific aim of this study was to validate the effect of different stacked half-hitch configuration and different braided suture materials on arthroscopic knot integrity. METHODS: Three different suture materials tied with five different RHAPs in arthroscopic knots were compared. A single load-to-failure test was performed and the mean ultimate clinical failure load was obtained. RESULTS: Significant knot holding strength improvement was found when one half-hitch was reversed as compared to baseline knot. When two of the half-hitches were reversed, there was a greater improvement with all knots having a mean ultimate clinical failure load greater than 150 newtons (N). Comparison of the suture materials demonstrated a higher mean ultimate clinical failure load when Force Fiber(®) was used and at least one half-hitch was reversed. Knots tied with either Force Fiber(®) or Orthocord(®) showed 0% chance of knot slippage while knots tied with FiberWire(®) or braided fishing line had about 10 and 30% knot slippage chances, respectively. CONCLUSIONS: A significant effect was observed in regards to both stacked half-hitch configuration and suture materials used on knot loop and knot security. Caution should be used with tying three RHAPs in arthroscopic surgery, particularly with a standard knot pusher and arthroscopic cannulas. The findings of this study indicated the importance of three RHAPs in performing arthroscopic knot tying and provided evidence regarding discrepancies of maximum clinical failure loads observed between orthopaedic surgeons, thereby leading to better surgical outcomes in the future.
format Online
Article
Text
id pubmed-5733413
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher University of Kansas Medical Center
record_format MEDLINE/PubMed
spelling pubmed-57334132018-02-22 Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity Chong, Alexander CM. Prohaska, Daniel J. Bye, Brian P. Kans J Med Original Research INTRODUCTION: With arthroscopic techniques being used, the importance of knot tying has been examined. Previous literature has examined the use of reversing half-hitches on alternating posts (RHAPs) on knot security. Separately, there has been research regarding different suture materials commonly used in the operating room. The specific aim of this study was to validate the effect of different stacked half-hitch configuration and different braided suture materials on arthroscopic knot integrity. METHODS: Three different suture materials tied with five different RHAPs in arthroscopic knots were compared. A single load-to-failure test was performed and the mean ultimate clinical failure load was obtained. RESULTS: Significant knot holding strength improvement was found when one half-hitch was reversed as compared to baseline knot. When two of the half-hitches were reversed, there was a greater improvement with all knots having a mean ultimate clinical failure load greater than 150 newtons (N). Comparison of the suture materials demonstrated a higher mean ultimate clinical failure load when Force Fiber(®) was used and at least one half-hitch was reversed. Knots tied with either Force Fiber(®) or Orthocord(®) showed 0% chance of knot slippage while knots tied with FiberWire(®) or braided fishing line had about 10 and 30% knot slippage chances, respectively. CONCLUSIONS: A significant effect was observed in regards to both stacked half-hitch configuration and suture materials used on knot loop and knot security. Caution should be used with tying three RHAPs in arthroscopic surgery, particularly with a standard knot pusher and arthroscopic cannulas. The findings of this study indicated the importance of three RHAPs in performing arthroscopic knot tying and provided evidence regarding discrepancies of maximum clinical failure loads observed between orthopaedic surgeons, thereby leading to better surgical outcomes in the future. University of Kansas Medical Center 2017-05-15 /pmc/articles/PMC5733413/ /pubmed/29472965 Text en © 2017 The University of Kansas Medical Center This is an open access article under the terms of the Attribution-ShareAlike CC BY-SA (https://creativecommons.org/licenses/by-sa/4.0/) . This license lets others remix, tweak, and build upon your work even for commercial purposes, as long as they credit you and license their new creations under the identical terms.
spellingShingle Original Research
Chong, Alexander CM.
Prohaska, Daniel J.
Bye, Brian P.
Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity
title Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity
title_full Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity
title_fullStr Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity
title_full_unstemmed Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity
title_short Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity
title_sort validation of different combination of three reversing half-hitches alternating posts (rhaps) effects on arthroscopic knot integrity
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5733413/
https://www.ncbi.nlm.nih.gov/pubmed/29472965
work_keys_str_mv AT chongalexandercm validationofdifferentcombinationofthreereversinghalfhitchesalternatingpostsrhapseffectsonarthroscopicknotintegrity
AT prohaskadanielj validationofdifferentcombinationofthreereversinghalfhitchesalternatingpostsrhapseffectsonarthroscopicknotintegrity
AT byebrianp validationofdifferentcombinationofthreereversinghalfhitchesalternatingpostsrhapseffectsonarthroscopicknotintegrity