Cargando…

Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection

A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimi...

Descripción completa

Detalles Bibliográficos
Autores principales: Jaszczak, Ewa, Ruman, Marek, Narkowicz, Sylwia, Namieśnik, Jacek, Polkowska, Żaneta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5733758/
https://www.ncbi.nlm.nih.gov/pubmed/29348966
http://dx.doi.org/10.1155/2017/7157953
_version_ 1783286938837450752
author Jaszczak, Ewa
Ruman, Marek
Narkowicz, Sylwia
Namieśnik, Jacek
Polkowska, Żaneta
author_facet Jaszczak, Ewa
Ruman, Marek
Narkowicz, Sylwia
Namieśnik, Jacek
Polkowska, Żaneta
author_sort Jaszczak, Ewa
collection PubMed
description A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detection limits (LODs) in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples.
format Online
Article
Text
id pubmed-5733758
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-57337582018-01-18 Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection Jaszczak, Ewa Ruman, Marek Narkowicz, Sylwia Namieśnik, Jacek Polkowska, Żaneta J Anal Methods Chem Research Article A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detection limits (LODs) in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples. Hindawi 2017 2017-11-21 /pmc/articles/PMC5733758/ /pubmed/29348966 http://dx.doi.org/10.1155/2017/7157953 Text en Copyright © 2017 Ewa Jaszczak et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Jaszczak, Ewa
Ruman, Marek
Narkowicz, Sylwia
Namieśnik, Jacek
Polkowska, Żaneta
Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
title Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
title_full Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
title_fullStr Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
title_full_unstemmed Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
title_short Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
title_sort development of an analytical protocol for determination of cyanide in human biological samples based on application of ion chromatography with pulsed amperometric detection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5733758/
https://www.ncbi.nlm.nih.gov/pubmed/29348966
http://dx.doi.org/10.1155/2017/7157953
work_keys_str_mv AT jaszczakewa developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection
AT rumanmarek developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection
AT narkowiczsylwia developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection
AT namiesnikjacek developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection
AT polkowskazaneta developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection