Cargando…
Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5733758/ https://www.ncbi.nlm.nih.gov/pubmed/29348966 http://dx.doi.org/10.1155/2017/7157953 |
_version_ | 1783286938837450752 |
---|---|
author | Jaszczak, Ewa Ruman, Marek Narkowicz, Sylwia Namieśnik, Jacek Polkowska, Żaneta |
author_facet | Jaszczak, Ewa Ruman, Marek Narkowicz, Sylwia Namieśnik, Jacek Polkowska, Żaneta |
author_sort | Jaszczak, Ewa |
collection | PubMed |
description | A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detection limits (LODs) in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples. |
format | Online Article Text |
id | pubmed-5733758 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-57337582018-01-18 Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection Jaszczak, Ewa Ruman, Marek Narkowicz, Sylwia Namieśnik, Jacek Polkowska, Żaneta J Anal Methods Chem Research Article A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detection limits (LODs) in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples. Hindawi 2017 2017-11-21 /pmc/articles/PMC5733758/ /pubmed/29348966 http://dx.doi.org/10.1155/2017/7157953 Text en Copyright © 2017 Ewa Jaszczak et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Jaszczak, Ewa Ruman, Marek Narkowicz, Sylwia Namieśnik, Jacek Polkowska, Żaneta Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection |
title | Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection |
title_full | Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection |
title_fullStr | Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection |
title_full_unstemmed | Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection |
title_short | Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection |
title_sort | development of an analytical protocol for determination of cyanide in human biological samples based on application of ion chromatography with pulsed amperometric detection |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5733758/ https://www.ncbi.nlm.nih.gov/pubmed/29348966 http://dx.doi.org/10.1155/2017/7157953 |
work_keys_str_mv | AT jaszczakewa developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection AT rumanmarek developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection AT narkowiczsylwia developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection AT namiesnikjacek developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection AT polkowskazaneta developmentofananalyticalprotocolfordeterminationofcyanideinhumanbiologicalsamplesbasedonapplicationofionchromatographywithpulsedamperometricdetection |