Cargando…
Comparisons of auditory brainstem response and sound level tolerance in tinnitus ears and non-tinnitus ears in unilateral tinnitus patients with normal audiograms
OBJECTIVE: Recently, “hidden hearing loss” with cochlear synaptopathy has been suggested as a potential pathophysiology of tinnitus in individuals with a normal hearing threshold. Several studies have demonstrated that subjects with tinnitus and normal audiograms show significantly reduced auditory...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5734686/ https://www.ncbi.nlm.nih.gov/pubmed/29253030 http://dx.doi.org/10.1371/journal.pone.0189157 |
_version_ | 1783287085448298496 |
---|---|
author | Shim, Hyun Joon An, Yong-Hwi Kim, Dong Hyun Yoon, Ji Eun Yoon, Ji Hyang |
author_facet | Shim, Hyun Joon An, Yong-Hwi Kim, Dong Hyun Yoon, Ji Eun Yoon, Ji Hyang |
author_sort | Shim, Hyun Joon |
collection | PubMed |
description | OBJECTIVE: Recently, “hidden hearing loss” with cochlear synaptopathy has been suggested as a potential pathophysiology of tinnitus in individuals with a normal hearing threshold. Several studies have demonstrated that subjects with tinnitus and normal audiograms show significantly reduced auditory brainstem response (ABR) wave I amplitudes compared with control subjects, but normal wave V amplitudes, suggesting increased central auditory gain. We aimed to reconfirm the “hidden hearing loss” theory through a within-subject comparison of wave I and wave V amplitudes and uncomfortable loudness level (UCL), which might be decreased with increased central gain, in tinnitus ears (TEs) and non-tinnitus ears (NTEs). SUBJECTS AND METHODS: Human subjects included 43 unilateral tinnitus patients (19 males, 24 females) with normal and symmetric hearing thresholds and 18 control subjects with normal audiograms. The amplitudes of wave I and V from the peak to the following trough were measured twice at 90 dB nHL and we separately assessed UCLs at 500 Hz and 3000 Hz pure tones in each TE and NTE. RESULTS: The within-subject comparison between TEs and NTEs showed no significant differences in wave I and wave V amplitude, or wave V/I ratio in both the male and female groups. Individual data revealed increased V/I amplitude ratios > mean + 2 SD in 3 TEs, but not in any control ears. We found no significant differences in UCL at 500 Hz or 3000 Hz between the TEs and NTEs, but the UCLs of both TEs and NTEs were lower than those of the control ears. CONCLUSIONS: Our ABR data do not represent meaningful evidence supporting the hypothesis of cochlear synaptopathy with increased central gain in tinnitus subjects with normal audiograms. However, reduced sound level tolerance in both TEs and NTEs might reflect increased central gain consequent on hidden synaptopathy that was subsequently balanced between the ears by lateral olivocochlear efferents. |
format | Online Article Text |
id | pubmed-5734686 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-57346862017-12-22 Comparisons of auditory brainstem response and sound level tolerance in tinnitus ears and non-tinnitus ears in unilateral tinnitus patients with normal audiograms Shim, Hyun Joon An, Yong-Hwi Kim, Dong Hyun Yoon, Ji Eun Yoon, Ji Hyang PLoS One Research Article OBJECTIVE: Recently, “hidden hearing loss” with cochlear synaptopathy has been suggested as a potential pathophysiology of tinnitus in individuals with a normal hearing threshold. Several studies have demonstrated that subjects with tinnitus and normal audiograms show significantly reduced auditory brainstem response (ABR) wave I amplitudes compared with control subjects, but normal wave V amplitudes, suggesting increased central auditory gain. We aimed to reconfirm the “hidden hearing loss” theory through a within-subject comparison of wave I and wave V amplitudes and uncomfortable loudness level (UCL), which might be decreased with increased central gain, in tinnitus ears (TEs) and non-tinnitus ears (NTEs). SUBJECTS AND METHODS: Human subjects included 43 unilateral tinnitus patients (19 males, 24 females) with normal and symmetric hearing thresholds and 18 control subjects with normal audiograms. The amplitudes of wave I and V from the peak to the following trough were measured twice at 90 dB nHL and we separately assessed UCLs at 500 Hz and 3000 Hz pure tones in each TE and NTE. RESULTS: The within-subject comparison between TEs and NTEs showed no significant differences in wave I and wave V amplitude, or wave V/I ratio in both the male and female groups. Individual data revealed increased V/I amplitude ratios > mean + 2 SD in 3 TEs, but not in any control ears. We found no significant differences in UCL at 500 Hz or 3000 Hz between the TEs and NTEs, but the UCLs of both TEs and NTEs were lower than those of the control ears. CONCLUSIONS: Our ABR data do not represent meaningful evidence supporting the hypothesis of cochlear synaptopathy with increased central gain in tinnitus subjects with normal audiograms. However, reduced sound level tolerance in both TEs and NTEs might reflect increased central gain consequent on hidden synaptopathy that was subsequently balanced between the ears by lateral olivocochlear efferents. Public Library of Science 2017-12-18 /pmc/articles/PMC5734686/ /pubmed/29253030 http://dx.doi.org/10.1371/journal.pone.0189157 Text en © 2017 Shim et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Shim, Hyun Joon An, Yong-Hwi Kim, Dong Hyun Yoon, Ji Eun Yoon, Ji Hyang Comparisons of auditory brainstem response and sound level tolerance in tinnitus ears and non-tinnitus ears in unilateral tinnitus patients with normal audiograms |
title | Comparisons of auditory brainstem response and sound level tolerance in tinnitus ears and non-tinnitus ears in unilateral tinnitus patients with normal audiograms |
title_full | Comparisons of auditory brainstem response and sound level tolerance in tinnitus ears and non-tinnitus ears in unilateral tinnitus patients with normal audiograms |
title_fullStr | Comparisons of auditory brainstem response and sound level tolerance in tinnitus ears and non-tinnitus ears in unilateral tinnitus patients with normal audiograms |
title_full_unstemmed | Comparisons of auditory brainstem response and sound level tolerance in tinnitus ears and non-tinnitus ears in unilateral tinnitus patients with normal audiograms |
title_short | Comparisons of auditory brainstem response and sound level tolerance in tinnitus ears and non-tinnitus ears in unilateral tinnitus patients with normal audiograms |
title_sort | comparisons of auditory brainstem response and sound level tolerance in tinnitus ears and non-tinnitus ears in unilateral tinnitus patients with normal audiograms |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5734686/ https://www.ncbi.nlm.nih.gov/pubmed/29253030 http://dx.doi.org/10.1371/journal.pone.0189157 |
work_keys_str_mv | AT shimhyunjoon comparisonsofauditorybrainstemresponseandsoundleveltoleranceintinnitusearsandnontinnitusearsinunilateraltinnituspatientswithnormalaudiograms AT anyonghwi comparisonsofauditorybrainstemresponseandsoundleveltoleranceintinnitusearsandnontinnitusearsinunilateraltinnituspatientswithnormalaudiograms AT kimdonghyun comparisonsofauditorybrainstemresponseandsoundleveltoleranceintinnitusearsandnontinnitusearsinunilateraltinnituspatientswithnormalaudiograms AT yoonjieun comparisonsofauditorybrainstemresponseandsoundleveltoleranceintinnitusearsandnontinnitusearsinunilateraltinnituspatientswithnormalaudiograms AT yoonjihyang comparisonsofauditorybrainstemresponseandsoundleveltoleranceintinnitusearsandnontinnitusearsinunilateraltinnituspatientswithnormalaudiograms |