Cargando…
R-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation
BACKGROUND: R-wave synchronised atrial pacing is an effective temporary pacing therapy in infants with postoperative junctional ectopic tachycardia. In the technique currently used, adverse short or long intervals between atrial pacing and ventricular sensing (AP–VS) may be observed during routine c...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5735521/ https://www.ncbi.nlm.nih.gov/pubmed/29258517 http://dx.doi.org/10.1186/s12938-017-0430-z |
_version_ | 1783287223136813056 |
---|---|
author | Entenmann, Andreas Michel, Miriam Ismer, Bruno Gebauer, Roman |
author_facet | Entenmann, Andreas Michel, Miriam Ismer, Bruno Gebauer, Roman |
author_sort | Entenmann, Andreas |
collection | PubMed |
description | BACKGROUND: R-wave synchronised atrial pacing is an effective temporary pacing therapy in infants with postoperative junctional ectopic tachycardia. In the technique currently used, adverse short or long intervals between atrial pacing and ventricular sensing (AP–VS) may be observed during routine clinical practice. OBJECTIVES: The aim of the study was to analyse outcomes of R-wave synchronised atrial pacing and the relationship between maximum tracking rates and AP–VS intervals. METHODS: Calculated AP–VS intervals were compared with those predicted by experienced pediatric cardiologist. RESULTS: A maximum tracking rate (MTR) set 10 bpm higher than the heart rate (HR) may result in undesirable short AP–VS intervals (minimum 83 ms). A MTR set 20 bpm above the HR is the hemodynamically better choice (minimum 96 ms). Effects of either setting on the AP–VS interval could not be predicted by experienced observers. In our newly proposed technique the AP–VS interval approaches 95 ms for HR > 210 bpm and 130 ms for HR < 130 bpm. The progression is linear and decreases strictly (− 0.4 ms/bpm) between the two extreme levels. CONCLUSIONS: Adjusting the AP–VS interval in the currently used technique is complex and may imply unfavorable pacemaker settings. A new pacemaker design is advisable to allow direct control of the AP–VS interval. |
format | Online Article Text |
id | pubmed-5735521 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-57355212017-12-21 R-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation Entenmann, Andreas Michel, Miriam Ismer, Bruno Gebauer, Roman Biomed Eng Online Research BACKGROUND: R-wave synchronised atrial pacing is an effective temporary pacing therapy in infants with postoperative junctional ectopic tachycardia. In the technique currently used, adverse short or long intervals between atrial pacing and ventricular sensing (AP–VS) may be observed during routine clinical practice. OBJECTIVES: The aim of the study was to analyse outcomes of R-wave synchronised atrial pacing and the relationship between maximum tracking rates and AP–VS intervals. METHODS: Calculated AP–VS intervals were compared with those predicted by experienced pediatric cardiologist. RESULTS: A maximum tracking rate (MTR) set 10 bpm higher than the heart rate (HR) may result in undesirable short AP–VS intervals (minimum 83 ms). A MTR set 20 bpm above the HR is the hemodynamically better choice (minimum 96 ms). Effects of either setting on the AP–VS interval could not be predicted by experienced observers. In our newly proposed technique the AP–VS interval approaches 95 ms for HR > 210 bpm and 130 ms for HR < 130 bpm. The progression is linear and decreases strictly (− 0.4 ms/bpm) between the two extreme levels. CONCLUSIONS: Adjusting the AP–VS interval in the currently used technique is complex and may imply unfavorable pacemaker settings. A new pacemaker design is advisable to allow direct control of the AP–VS interval. BioMed Central 2017-12-19 /pmc/articles/PMC5735521/ /pubmed/29258517 http://dx.doi.org/10.1186/s12938-017-0430-z Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Entenmann, Andreas Michel, Miriam Ismer, Bruno Gebauer, Roman R-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation |
title | R-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation |
title_full | R-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation |
title_fullStr | R-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation |
title_full_unstemmed | R-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation |
title_short | R-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation |
title_sort | r-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5735521/ https://www.ncbi.nlm.nih.gov/pubmed/29258517 http://dx.doi.org/10.1186/s12938-017-0430-z |
work_keys_str_mv | AT entenmannandreas rwavesynchronisedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardiatheatrioventricularintervalinvestigatedbycomputationalanalysisandclinicalevaluation AT michelmiriam rwavesynchronisedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardiatheatrioventricularintervalinvestigatedbycomputationalanalysisandclinicalevaluation AT ismerbruno rwavesynchronisedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardiatheatrioventricularintervalinvestigatedbycomputationalanalysisandclinicalevaluation AT gebauerroman rwavesynchronisedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardiatheatrioventricularintervalinvestigatedbycomputationalanalysisandclinicalevaluation |