Cargando…

Application of updated guidelines on diastolic dysfunction in patients with severe sepsis and septic shock

BACKGROUND: Left ventricular diastolic dysfunction is suggested to be associated with higher mortality in severe sepsis and septic shock, yet the methods of diagnosis described in the literature are often inconsistent. The recently published 2016 American Society of Echocardiography and European Ass...

Descripción completa

Detalles Bibliográficos
Autores principales: Clancy, David J., Scully, Timothy, Slama, Michel, Huang, Stephen, McLean, Anthony S., Orde, Sam R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5736511/
https://www.ncbi.nlm.nih.gov/pubmed/29260409
http://dx.doi.org/10.1186/s13613-017-0342-x
_version_ 1783287364626415616
author Clancy, David J.
Scully, Timothy
Slama, Michel
Huang, Stephen
McLean, Anthony S.
Orde, Sam R.
author_facet Clancy, David J.
Scully, Timothy
Slama, Michel
Huang, Stephen
McLean, Anthony S.
Orde, Sam R.
author_sort Clancy, David J.
collection PubMed
description BACKGROUND: Left ventricular diastolic dysfunction is suggested to be associated with higher mortality in severe sepsis and septic shock, yet the methods of diagnosis described in the literature are often inconsistent. The recently published 2016 American Society of Echocardiography and European Association of Cardiovascular Imaging (ASE/EACVI) guidelines offer the opportunity to apply a simple pragmatic diagnostic algorithm for the detection of diastolic dysfunction; however, it has not been tested in this cohort. AIMS: We sought to assess the applicability in septic patients of recently published 2016 ASE/EACVI guidelines on diastolic dysfunction compared with the 2009 ASE guidelines. Our hypothesis was that there would be poor agreement in classifying patients. METHODS: Prospective observational study includes patients identified as having severe sepsis and septic shock. Patients underwent transthoracic echocardiography on day 1 and day 3 of their ICU admission. Patients with normal and abnormal (ejection fraction < 52%) systolic function had their diastolic function stratified according to both the 2009 ASE and 2016 ASE/EACVI guidelines. RESULTS: On day 1 echocardiography, of the 62 patients analysed, 37 (60%) had diastolic dysfunction according to the 2016 ASE/EACVI guideline with a further 23% having indeterminate diastolic function, compared to the 2009 ASE guidelines where only 13 (21%) had confirmed diastolic dysfunction with 46 (74%) having indeterminate diastolic dysfunction. On day 3, of the 55 patients studied, 22 patients (40%) were defined as having diastolic dysfunction, with 6 (11%) having indeterminate diastolic dysfunction according to the 2016 ASE/EACVI guidelines, compared to the 2009 guidelines where 11 (20%) were confirmed to have diastolic dysfunction and 41 (75%) had indeterminate diastolic function. Systolic dysfunction was identified in 18 of 62 patients (29%) on day 1 and 18 of 55 (33%) on day 3. These patients were classified as having abnormal diastolic function in 94 and 89% with the 2016 guidelines on day 1 and day 3, respectively, compared with 50 and 28% using the 2009 guidelines. The 2016 guidelines had less patients with indeterminate diastolic function on days 1 and 3 (11 and 6%) compared to the 2009 guidelines (50 and 72%). Normal systolic function was identified in 44 patients on day 1 and 37 on day 3. In this group, abnormal diastolic function was present in 45 and 54% on days 1 and 3 according to the 2016 ASE/EACVI guidelines, compared with 9 and 16% using the 2009 guidelines, respectively. In those with normal systolic function, the 2016 guidelines had less indeterminate patients with 30 and 16% on days 1 and 3, respectively, compared to 84 and 76% in the 2009 guidelines. CONCLUSION: The 2016 ASE/EACVI diastolic function guidelines identify a significantly higher incidence of dysfunction in patients with severe sepsis and septic shock compared to the previous 2009 guidelines. Although the new guidelines seem to be an improvement, issues remain with the application of guidelines using traditional measures of diastolic dysfunction in this cohort. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13613-017-0342-x) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5736511
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-57365112017-12-20 Application of updated guidelines on diastolic dysfunction in patients with severe sepsis and septic shock Clancy, David J. Scully, Timothy Slama, Michel Huang, Stephen McLean, Anthony S. Orde, Sam R. Ann Intensive Care Research BACKGROUND: Left ventricular diastolic dysfunction is suggested to be associated with higher mortality in severe sepsis and septic shock, yet the methods of diagnosis described in the literature are often inconsistent. The recently published 2016 American Society of Echocardiography and European Association of Cardiovascular Imaging (ASE/EACVI) guidelines offer the opportunity to apply a simple pragmatic diagnostic algorithm for the detection of diastolic dysfunction; however, it has not been tested in this cohort. AIMS: We sought to assess the applicability in septic patients of recently published 2016 ASE/EACVI guidelines on diastolic dysfunction compared with the 2009 ASE guidelines. Our hypothesis was that there would be poor agreement in classifying patients. METHODS: Prospective observational study includes patients identified as having severe sepsis and septic shock. Patients underwent transthoracic echocardiography on day 1 and day 3 of their ICU admission. Patients with normal and abnormal (ejection fraction < 52%) systolic function had their diastolic function stratified according to both the 2009 ASE and 2016 ASE/EACVI guidelines. RESULTS: On day 1 echocardiography, of the 62 patients analysed, 37 (60%) had diastolic dysfunction according to the 2016 ASE/EACVI guideline with a further 23% having indeterminate diastolic function, compared to the 2009 ASE guidelines where only 13 (21%) had confirmed diastolic dysfunction with 46 (74%) having indeterminate diastolic dysfunction. On day 3, of the 55 patients studied, 22 patients (40%) were defined as having diastolic dysfunction, with 6 (11%) having indeterminate diastolic dysfunction according to the 2016 ASE/EACVI guidelines, compared to the 2009 guidelines where 11 (20%) were confirmed to have diastolic dysfunction and 41 (75%) had indeterminate diastolic function. Systolic dysfunction was identified in 18 of 62 patients (29%) on day 1 and 18 of 55 (33%) on day 3. These patients were classified as having abnormal diastolic function in 94 and 89% with the 2016 guidelines on day 1 and day 3, respectively, compared with 50 and 28% using the 2009 guidelines. The 2016 guidelines had less patients with indeterminate diastolic function on days 1 and 3 (11 and 6%) compared to the 2009 guidelines (50 and 72%). Normal systolic function was identified in 44 patients on day 1 and 37 on day 3. In this group, abnormal diastolic function was present in 45 and 54% on days 1 and 3 according to the 2016 ASE/EACVI guidelines, compared with 9 and 16% using the 2009 guidelines, respectively. In those with normal systolic function, the 2016 guidelines had less indeterminate patients with 30 and 16% on days 1 and 3, respectively, compared to 84 and 76% in the 2009 guidelines. CONCLUSION: The 2016 ASE/EACVI diastolic function guidelines identify a significantly higher incidence of dysfunction in patients with severe sepsis and septic shock compared to the previous 2009 guidelines. Although the new guidelines seem to be an improvement, issues remain with the application of guidelines using traditional measures of diastolic dysfunction in this cohort. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13613-017-0342-x) contains supplementary material, which is available to authorized users. Springer International Publishing 2017-12-19 /pmc/articles/PMC5736511/ /pubmed/29260409 http://dx.doi.org/10.1186/s13613-017-0342-x Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Clancy, David J.
Scully, Timothy
Slama, Michel
Huang, Stephen
McLean, Anthony S.
Orde, Sam R.
Application of updated guidelines on diastolic dysfunction in patients with severe sepsis and septic shock
title Application of updated guidelines on diastolic dysfunction in patients with severe sepsis and septic shock
title_full Application of updated guidelines on diastolic dysfunction in patients with severe sepsis and septic shock
title_fullStr Application of updated guidelines on diastolic dysfunction in patients with severe sepsis and septic shock
title_full_unstemmed Application of updated guidelines on diastolic dysfunction in patients with severe sepsis and septic shock
title_short Application of updated guidelines on diastolic dysfunction in patients with severe sepsis and septic shock
title_sort application of updated guidelines on diastolic dysfunction in patients with severe sepsis and septic shock
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5736511/
https://www.ncbi.nlm.nih.gov/pubmed/29260409
http://dx.doi.org/10.1186/s13613-017-0342-x
work_keys_str_mv AT clancydavidj applicationofupdatedguidelinesondiastolicdysfunctioninpatientswithseveresepsisandsepticshock
AT scullytimothy applicationofupdatedguidelinesondiastolicdysfunctioninpatientswithseveresepsisandsepticshock
AT slamamichel applicationofupdatedguidelinesondiastolicdysfunctioninpatientswithseveresepsisandsepticshock
AT huangstephen applicationofupdatedguidelinesondiastolicdysfunctioninpatientswithseveresepsisandsepticshock
AT mcleananthonys applicationofupdatedguidelinesondiastolicdysfunctioninpatientswithseveresepsisandsepticshock
AT ordesamr applicationofupdatedguidelinesondiastolicdysfunctioninpatientswithseveresepsisandsepticshock