Cargando…

Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions

PURPOSE: The goal of this study was to evaluate the fracture resistances of various monolithic crowns fabricated by computer-aided design and computer-aided manufacturing (CAD/CAM) with different thickness. MATERIALS AND METHODS: Test dies were fabricated as mandibular molar forms with occlusal redu...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Sulki, Yoon, Hyung-In, Park, Eun-Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5741445/
https://www.ncbi.nlm.nih.gov/pubmed/29279761
http://dx.doi.org/10.4047/jap.2017.9.6.423
_version_ 1783288195195076608
author Choi, Sulki
Yoon, Hyung-In
Park, Eun-Jin
author_facet Choi, Sulki
Yoon, Hyung-In
Park, Eun-Jin
author_sort Choi, Sulki
collection PubMed
description PURPOSE: The goal of this study was to evaluate the fracture resistances of various monolithic crowns fabricated by computer-aided design and computer-aided manufacturing (CAD/CAM) with different thickness. MATERIALS AND METHODS: Test dies were fabricated as mandibular molar forms with occlusal reductions using CAD/CAM. With different occlusal thickness (1.0 or 1.5 mm), a polymer-infiltrated ceramic network (Enamic, EN), and zirconia-reinforced lithium silicate (Suprinity, SU and Celtra-Duo, CD) were used to fabricate molar crowns. Lithium disilicate (e.max CAD, EM) crowns (occlusal: 1.5 mm) were fabricated as control. Seventy crowns (n=10 per group) were bonded to abutments and stored in water for 24 hours. A universal testing machine was used to apply load to crown until fracture. The fractured specimens were examined with a scanning electron microscopy. RESULTS: The type of ceramics and the occlusal thickness showed a significant interaction. With a recommended thickness (1.5 mm), the SU revealed the mean load similar to the EM, higher compared with those of the EN and CD. The fracture loads in a reduced thickness (1.0 mm) were similar among the SU, CD, and EN. The mean fracture load of the SU and CD enhanced significantly when the occlusal thickness increased, whereas that of the EN did not. CONCLUSION: The fracture loads of monolithic crowns were differently influenced by the changes in occlusal thickness, depending on the type of ceramics. Within the limitations of this study, all the tested crowns withstood the physiological masticatory loads both at the recommended and reduced occlusal thickness.
format Online
Article
Text
id pubmed-5741445
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-57414452017-12-26 Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions Choi, Sulki Yoon, Hyung-In Park, Eun-Jin J Adv Prosthodont Original Article PURPOSE: The goal of this study was to evaluate the fracture resistances of various monolithic crowns fabricated by computer-aided design and computer-aided manufacturing (CAD/CAM) with different thickness. MATERIALS AND METHODS: Test dies were fabricated as mandibular molar forms with occlusal reductions using CAD/CAM. With different occlusal thickness (1.0 or 1.5 mm), a polymer-infiltrated ceramic network (Enamic, EN), and zirconia-reinforced lithium silicate (Suprinity, SU and Celtra-Duo, CD) were used to fabricate molar crowns. Lithium disilicate (e.max CAD, EM) crowns (occlusal: 1.5 mm) were fabricated as control. Seventy crowns (n=10 per group) were bonded to abutments and stored in water for 24 hours. A universal testing machine was used to apply load to crown until fracture. The fractured specimens were examined with a scanning electron microscopy. RESULTS: The type of ceramics and the occlusal thickness showed a significant interaction. With a recommended thickness (1.5 mm), the SU revealed the mean load similar to the EM, higher compared with those of the EN and CD. The fracture loads in a reduced thickness (1.0 mm) were similar among the SU, CD, and EN. The mean fracture load of the SU and CD enhanced significantly when the occlusal thickness increased, whereas that of the EN did not. CONCLUSION: The fracture loads of monolithic crowns were differently influenced by the changes in occlusal thickness, depending on the type of ceramics. Within the limitations of this study, all the tested crowns withstood the physiological masticatory loads both at the recommended and reduced occlusal thickness. The Korean Academy of Prosthodontics 2017-12 2017-12-14 /pmc/articles/PMC5741445/ /pubmed/29279761 http://dx.doi.org/10.4047/jap.2017.9.6.423 Text en © 2017 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Choi, Sulki
Yoon, Hyung-In
Park, Eun-Jin
Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions
title Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions
title_full Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions
title_fullStr Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions
title_full_unstemmed Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions
title_short Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions
title_sort load-bearing capacity of various cad/cam monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5741445/
https://www.ncbi.nlm.nih.gov/pubmed/29279761
http://dx.doi.org/10.4047/jap.2017.9.6.423
work_keys_str_mv AT choisulki loadbearingcapacityofvariouscadcammonolithicmolarcrownsunderrecommendedocclusalthicknessandreducedocclusalthicknessconditions
AT yoonhyungin loadbearingcapacityofvariouscadcammonolithicmolarcrownsunderrecommendedocclusalthicknessandreducedocclusalthicknessconditions
AT parkeunjin loadbearingcapacityofvariouscadcammonolithicmolarcrownsunderrecommendedocclusalthicknessandreducedocclusalthicknessconditions