Cargando…
Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography
PURPOSE: To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. METHODS: Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeata...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5742459/ https://www.ncbi.nlm.nih.gov/pubmed/29375908 http://dx.doi.org/10.1155/2017/1516395 |
_version_ | 1783288380495233024 |
---|---|
author | Jung, Soyeon Chin, Hee Seung Kim, Na Rae Lee, Kang Won Jung, Ji Won |
author_facet | Jung, Soyeon Chin, Hee Seung Kim, Na Rae Lee, Kang Won Jung, Ji Won |
author_sort | Jung, Soyeon |
collection | PubMed |
description | PURPOSE: To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. METHODS: Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. RESULTS: Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT (P > 0.050), although flattest K, mean K, and CCT differed (P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. CONCLUSIONS: Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error. |
format | Online Article Text |
id | pubmed-5742459 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-57424592018-01-28 Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography Jung, Soyeon Chin, Hee Seung Kim, Na Rae Lee, Kang Won Jung, Ji Won J Ophthalmol Research Article PURPOSE: To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. METHODS: Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. RESULTS: Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT (P > 0.050), although flattest K, mean K, and CCT differed (P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. CONCLUSIONS: Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error. Hindawi 2017 2017-12-10 /pmc/articles/PMC5742459/ /pubmed/29375908 http://dx.doi.org/10.1155/2017/1516395 Text en Copyright © 2017 Soyeon Jung et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Jung, Soyeon Chin, Hee Seung Kim, Na Rae Lee, Kang Won Jung, Ji Won Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography |
title | Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography |
title_full | Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography |
title_fullStr | Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography |
title_full_unstemmed | Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography |
title_short | Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography |
title_sort | comparison of repeatability and agreement between swept-source optical biometry and dual-scheimpflug topography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5742459/ https://www.ncbi.nlm.nih.gov/pubmed/29375908 http://dx.doi.org/10.1155/2017/1516395 |
work_keys_str_mv | AT jungsoyeon comparisonofrepeatabilityandagreementbetweensweptsourceopticalbiometryanddualscheimpflugtopography AT chinheeseung comparisonofrepeatabilityandagreementbetweensweptsourceopticalbiometryanddualscheimpflugtopography AT kimnarae comparisonofrepeatabilityandagreementbetweensweptsourceopticalbiometryanddualscheimpflugtopography AT leekangwon comparisonofrepeatabilityandagreementbetweensweptsourceopticalbiometryanddualscheimpflugtopography AT jungjiwon comparisonofrepeatabilityandagreementbetweensweptsourceopticalbiometryanddualscheimpflugtopography |