Cargando…

Investigation of the Longitudinal Relaxation Time of Rat Tibial Cortical Bone Using SWIFT

Sweep imaging with Fourier transform (SWIFT) method has been developed to image tissues with very short T(2) values, such as cortical bone. The purpose of this study was to measure the T(1) value of the rat cortical bone. It was approximately 120 ms on 7.04T. This result could thus be useful for stu...

Descripción completa

Detalles Bibliográficos
Autores principales: Sukenari, Tsuyoshi, Ikoma, Kazuya, Horii, Motoyuki, Umeda, Masahiro, Kido, Masamitsu, Hayashi, Shigeki, Hara, Yusuke, Yamasaki, Tetsuro, Onishi, Okihiro, Morihara, Toru, Fujiwara, Hiroyoshi, Kawata, Mitsuhiro, Kubo, Toshikazu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Magnetic Resonance in Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5743527/
https://www.ncbi.nlm.nih.gov/pubmed/27941296
http://dx.doi.org/10.2463/mrms.tn.2016-0050
_version_ 1783288584396079104
author Sukenari, Tsuyoshi
Ikoma, Kazuya
Horii, Motoyuki
Umeda, Masahiro
Kido, Masamitsu
Hayashi, Shigeki
Hara, Yusuke
Yamasaki, Tetsuro
Onishi, Okihiro
Morihara, Toru
Fujiwara, Hiroyoshi
Kawata, Mitsuhiro
Kubo, Toshikazu
author_facet Sukenari, Tsuyoshi
Ikoma, Kazuya
Horii, Motoyuki
Umeda, Masahiro
Kido, Masamitsu
Hayashi, Shigeki
Hara, Yusuke
Yamasaki, Tetsuro
Onishi, Okihiro
Morihara, Toru
Fujiwara, Hiroyoshi
Kawata, Mitsuhiro
Kubo, Toshikazu
author_sort Sukenari, Tsuyoshi
collection PubMed
description Sweep imaging with Fourier transform (SWIFT) method has been developed to image tissues with very short T(2) values, such as cortical bone. The purpose of this study was to measure the T(1) value of the rat cortical bone. It was approximately 120 ms on 7.04T. This result could thus be useful for studying bony tissue according to the SWIFT method in the future.
format Online
Article
Text
id pubmed-5743527
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Japanese Society for Magnetic Resonance in Medicine
record_format MEDLINE/PubMed
spelling pubmed-57435272018-01-04 Investigation of the Longitudinal Relaxation Time of Rat Tibial Cortical Bone Using SWIFT Sukenari, Tsuyoshi Ikoma, Kazuya Horii, Motoyuki Umeda, Masahiro Kido, Masamitsu Hayashi, Shigeki Hara, Yusuke Yamasaki, Tetsuro Onishi, Okihiro Morihara, Toru Fujiwara, Hiroyoshi Kawata, Mitsuhiro Kubo, Toshikazu Magn Reson Med Sci Technical Note Sweep imaging with Fourier transform (SWIFT) method has been developed to image tissues with very short T(2) values, such as cortical bone. The purpose of this study was to measure the T(1) value of the rat cortical bone. It was approximately 120 ms on 7.04T. This result could thus be useful for studying bony tissue according to the SWIFT method in the future. Japanese Society for Magnetic Resonance in Medicine 2016-12-12 /pmc/articles/PMC5743527/ /pubmed/27941296 http://dx.doi.org/10.2463/mrms.tn.2016-0050 Text en © 2016 Japanese Society for Magnetic Resonance in Medicine http://creativecommons.org/licenses/by/3.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License.
spellingShingle Technical Note
Sukenari, Tsuyoshi
Ikoma, Kazuya
Horii, Motoyuki
Umeda, Masahiro
Kido, Masamitsu
Hayashi, Shigeki
Hara, Yusuke
Yamasaki, Tetsuro
Onishi, Okihiro
Morihara, Toru
Fujiwara, Hiroyoshi
Kawata, Mitsuhiro
Kubo, Toshikazu
Investigation of the Longitudinal Relaxation Time of Rat Tibial Cortical Bone Using SWIFT
title Investigation of the Longitudinal Relaxation Time of Rat Tibial Cortical Bone Using SWIFT
title_full Investigation of the Longitudinal Relaxation Time of Rat Tibial Cortical Bone Using SWIFT
title_fullStr Investigation of the Longitudinal Relaxation Time of Rat Tibial Cortical Bone Using SWIFT
title_full_unstemmed Investigation of the Longitudinal Relaxation Time of Rat Tibial Cortical Bone Using SWIFT
title_short Investigation of the Longitudinal Relaxation Time of Rat Tibial Cortical Bone Using SWIFT
title_sort investigation of the longitudinal relaxation time of rat tibial cortical bone using swift
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5743527/
https://www.ncbi.nlm.nih.gov/pubmed/27941296
http://dx.doi.org/10.2463/mrms.tn.2016-0050
work_keys_str_mv AT sukenaritsuyoshi investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT ikomakazuya investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT horiimotoyuki investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT umedamasahiro investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT kidomasamitsu investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT hayashishigeki investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT harayusuke investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT yamasakitetsuro investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT onishiokihiro investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT moriharatoru investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT fujiwarahiroyoshi investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT kawatamitsuhiro investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift
AT kubotoshikazu investigationofthelongitudinalrelaxationtimeofrattibialcorticalboneusingswift