Cargando…

In Vitro Evaluation of PCL and P(3HB) as Coating Materials for Selective Laser Melted Porous Titanium Implants

Titanium is widely used as a bone implant material due to its biocompatibility and high resilience. Since its Young’s modulus differs from bone tissue, the resulting “stress shielding” could lead to scaffold loosening. However, by using a scaffold-shaped geometry, the Young’s modulus can be adjusted...

Descripción completa

Detalles Bibliográficos
Autores principales: Grau, Michael, Matena, Julia, Teske, Michael, Petersen, Svea, Aliuos, Pooyan, Roland, Laura, Grabow, Niels, Murua Escobar, Hugo, Gellrich, Nils-Claudius, Haferkamp, Heinz, Nolte, Ingo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5744279/
https://www.ncbi.nlm.nih.gov/pubmed/29168794
http://dx.doi.org/10.3390/ma10121344
_version_ 1783288712038187008
author Grau, Michael
Matena, Julia
Teske, Michael
Petersen, Svea
Aliuos, Pooyan
Roland, Laura
Grabow, Niels
Murua Escobar, Hugo
Gellrich, Nils-Claudius
Haferkamp, Heinz
Nolte, Ingo
author_facet Grau, Michael
Matena, Julia
Teske, Michael
Petersen, Svea
Aliuos, Pooyan
Roland, Laura
Grabow, Niels
Murua Escobar, Hugo
Gellrich, Nils-Claudius
Haferkamp, Heinz
Nolte, Ingo
author_sort Grau, Michael
collection PubMed
description Titanium is widely used as a bone implant material due to its biocompatibility and high resilience. Since its Young’s modulus differs from bone tissue, the resulting “stress shielding” could lead to scaffold loosening. However, by using a scaffold-shaped geometry, the Young’s modulus can be adjusted. Also, a porous geometry enables vascularisation and bone ingrowth inside the implant itself. Additionally, growth factors can improve these effects. In order to create a deposit and release system for these factors, the titanium scaffolds could be coated with degradable polymers. Therefore, in the present study, synthetic poly-ε-caprolactone (PCL) and the biopolymer poly(3-hydroxybutyrate) (P(3HB)) were tested for coating efficiency, cell adhesion, and biocompatibility to find a suitable coating material. The underlying scaffold was created from titanium by Selective Laser Melting (SLM) and coated with PCL or P(3HB) via dip coating. To test the biocompatibility, Live Cell Imaging (LCI) as well as vitality and proliferation assays were performed. In addition, cell adhesion forces were detected via Single Cell Force Spectroscopy, while the coating efficiency was observed using environmental scanning electron microscopy (ESEM) and energy-dispersive X-ray (EDX) analyses. Regarding the coating efficiency, PCL showed higher values in comparison to P(3HB). Vitality assays revealed decent vitality values for both polymers, while values for PCL were significantly lower than those for blank titanium. No significant differences could be observed between PCL and P(3HB) in proliferation and cell adhesion studies. Although LCI observations revealed decreasing values in cell number and populated area over time on both polymer-coated scaffolds, these outcomes could be explained by the possibility of coating diluent residues accumulating in the culture medium. Overall, both polymers fulfill the requirements regarding biocompatibility. Nonetheless, since only PCL coating ensured the maintenance of the porous implant structure, it is preferable to be used as a coating material for creating a deposit and release system for growth factors.
format Online
Article
Text
id pubmed-5744279
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57442792017-12-31 In Vitro Evaluation of PCL and P(3HB) as Coating Materials for Selective Laser Melted Porous Titanium Implants Grau, Michael Matena, Julia Teske, Michael Petersen, Svea Aliuos, Pooyan Roland, Laura Grabow, Niels Murua Escobar, Hugo Gellrich, Nils-Claudius Haferkamp, Heinz Nolte, Ingo Materials (Basel) Article Titanium is widely used as a bone implant material due to its biocompatibility and high resilience. Since its Young’s modulus differs from bone tissue, the resulting “stress shielding” could lead to scaffold loosening. However, by using a scaffold-shaped geometry, the Young’s modulus can be adjusted. Also, a porous geometry enables vascularisation and bone ingrowth inside the implant itself. Additionally, growth factors can improve these effects. In order to create a deposit and release system for these factors, the titanium scaffolds could be coated with degradable polymers. Therefore, in the present study, synthetic poly-ε-caprolactone (PCL) and the biopolymer poly(3-hydroxybutyrate) (P(3HB)) were tested for coating efficiency, cell adhesion, and biocompatibility to find a suitable coating material. The underlying scaffold was created from titanium by Selective Laser Melting (SLM) and coated with PCL or P(3HB) via dip coating. To test the biocompatibility, Live Cell Imaging (LCI) as well as vitality and proliferation assays were performed. In addition, cell adhesion forces were detected via Single Cell Force Spectroscopy, while the coating efficiency was observed using environmental scanning electron microscopy (ESEM) and energy-dispersive X-ray (EDX) analyses. Regarding the coating efficiency, PCL showed higher values in comparison to P(3HB). Vitality assays revealed decent vitality values for both polymers, while values for PCL were significantly lower than those for blank titanium. No significant differences could be observed between PCL and P(3HB) in proliferation and cell adhesion studies. Although LCI observations revealed decreasing values in cell number and populated area over time on both polymer-coated scaffolds, these outcomes could be explained by the possibility of coating diluent residues accumulating in the culture medium. Overall, both polymers fulfill the requirements regarding biocompatibility. Nonetheless, since only PCL coating ensured the maintenance of the porous implant structure, it is preferable to be used as a coating material for creating a deposit and release system for growth factors. MDPI 2017-11-23 /pmc/articles/PMC5744279/ /pubmed/29168794 http://dx.doi.org/10.3390/ma10121344 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Grau, Michael
Matena, Julia
Teske, Michael
Petersen, Svea
Aliuos, Pooyan
Roland, Laura
Grabow, Niels
Murua Escobar, Hugo
Gellrich, Nils-Claudius
Haferkamp, Heinz
Nolte, Ingo
In Vitro Evaluation of PCL and P(3HB) as Coating Materials for Selective Laser Melted Porous Titanium Implants
title In Vitro Evaluation of PCL and P(3HB) as Coating Materials for Selective Laser Melted Porous Titanium Implants
title_full In Vitro Evaluation of PCL and P(3HB) as Coating Materials for Selective Laser Melted Porous Titanium Implants
title_fullStr In Vitro Evaluation of PCL and P(3HB) as Coating Materials for Selective Laser Melted Porous Titanium Implants
title_full_unstemmed In Vitro Evaluation of PCL and P(3HB) as Coating Materials for Selective Laser Melted Porous Titanium Implants
title_short In Vitro Evaluation of PCL and P(3HB) as Coating Materials for Selective Laser Melted Porous Titanium Implants
title_sort in vitro evaluation of pcl and p(3hb) as coating materials for selective laser melted porous titanium implants
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5744279/
https://www.ncbi.nlm.nih.gov/pubmed/29168794
http://dx.doi.org/10.3390/ma10121344
work_keys_str_mv AT graumichael invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT matenajulia invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT teskemichael invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT petersensvea invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT aliuospooyan invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT rolandlaura invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT grabowniels invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT muruaescobarhugo invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT gellrichnilsclaudius invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT haferkampheinz invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants
AT nolteingo invitroevaluationofpclandp3hbascoatingmaterialsforselectivelasermeltedporoustitaniumimplants