Cargando…
Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries
OBJECTIVES: When a patient has cone beam computed tomography (CBCT) images based on the treatment plan, it is possible to use these images for evaluation of caries, and there is no need for new radiographs, according to the “as low as reasonably achievable” (ALARA) principle. The aim of this study w...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tehran University of Medical Sciences
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5745226/ https://www.ncbi.nlm.nih.gov/pubmed/29285032 |
_version_ | 1783288878487044096 |
---|---|
author | Abdinian, Mehrdad Nazeri, Rahman Ghaiour, Marzieh |
author_facet | Abdinian, Mehrdad Nazeri, Rahman Ghaiour, Marzieh |
author_sort | Abdinian, Mehrdad |
collection | PubMed |
description | OBJECTIVES: When a patient has cone beam computed tomography (CBCT) images based on the treatment plan, it is possible to use these images for evaluation of caries, and there is no need for new radiographs, according to the “as low as reasonably achievable” (ALARA) principle. The aim of this study was to determine the effect of filtration and thickness of CBCT cross-sections on detection of proximal caries. MATERIALS AND METHODS: In this in-vitro study, 100 teeth were placed in the dental sockets of a dry skull, and were fixed in normal proximal contacts. CBCT images were taken and were evaluated by two observers on the panoramic view at 1-, 3- and 5-mm-thick cross-sections, with the use of filtrations 0, 1 and 2. Afterwards, the samples were sectioned and underwent a histological evaluation. McNemar’s test was used to compare the findings on CBCT images and histological evaluation. Receiver operating characteristic (ROC) curves and logistic regression were used to evaluate the diagnostic accuracy of different cross-sections. RESULTS: The maximum AZ-value was achieved at 3-mm thickness/filtration 2. However, the differences between 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1 were not significant (P=0.728 and 0.868, respectively). The minimum AZ-value was achieved at 5-mm thickness/filtration 0. CONCLUSIONS: Although CBCT is not sufficiently effective in detecting caries, the best cross-sections for detection of proximal caries were achieved at 3-mm thickness/filtration 2, 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1. |
format | Online Article Text |
id | pubmed-5745226 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Tehran University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-57452262017-12-28 Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries Abdinian, Mehrdad Nazeri, Rahman Ghaiour, Marzieh J Dent (Tehran) Original Article OBJECTIVES: When a patient has cone beam computed tomography (CBCT) images based on the treatment plan, it is possible to use these images for evaluation of caries, and there is no need for new radiographs, according to the “as low as reasonably achievable” (ALARA) principle. The aim of this study was to determine the effect of filtration and thickness of CBCT cross-sections on detection of proximal caries. MATERIALS AND METHODS: In this in-vitro study, 100 teeth were placed in the dental sockets of a dry skull, and were fixed in normal proximal contacts. CBCT images were taken and were evaluated by two observers on the panoramic view at 1-, 3- and 5-mm-thick cross-sections, with the use of filtrations 0, 1 and 2. Afterwards, the samples were sectioned and underwent a histological evaluation. McNemar’s test was used to compare the findings on CBCT images and histological evaluation. Receiver operating characteristic (ROC) curves and logistic regression were used to evaluate the diagnostic accuracy of different cross-sections. RESULTS: The maximum AZ-value was achieved at 3-mm thickness/filtration 2. However, the differences between 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1 were not significant (P=0.728 and 0.868, respectively). The minimum AZ-value was achieved at 5-mm thickness/filtration 0. CONCLUSIONS: Although CBCT is not sufficiently effective in detecting caries, the best cross-sections for detection of proximal caries were achieved at 3-mm thickness/filtration 2, 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1. Tehran University of Medical Sciences 2017-07 /pmc/articles/PMC5745226/ /pubmed/29285032 Text en Copyright© Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Abdinian, Mehrdad Nazeri, Rahman Ghaiour, Marzieh Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries |
title | Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries |
title_full | Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries |
title_fullStr | Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries |
title_full_unstemmed | Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries |
title_short | Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries |
title_sort | effect of filtration and thickness of cross-sections of cone beam computed tomography images on detection of proximal caries |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5745226/ https://www.ncbi.nlm.nih.gov/pubmed/29285032 |
work_keys_str_mv | AT abdinianmehrdad effectoffiltrationandthicknessofcrosssectionsofconebeamcomputedtomographyimagesondetectionofproximalcaries AT nazerirahman effectoffiltrationandthicknessofcrosssectionsofconebeamcomputedtomographyimagesondetectionofproximalcaries AT ghaiourmarzieh effectoffiltrationandthicknessofcrosssectionsofconebeamcomputedtomographyimagesondetectionofproximalcaries |