Cargando…
A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes
Measuring the temperature of a sample is a fundamental need in many biological and chemical processes. When the volume of the sample is on the microliter or nanoliter scale (e.g., cells, microorganisms, precious samples, or samples in microfluidic devices), accurate measurement of the sample tempera...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5746210/ https://www.ncbi.nlm.nih.gov/pubmed/29284028 http://dx.doi.org/10.1371/journal.pone.0189430 |
_version_ | 1783289057711751168 |
---|---|
author | McKenzie, Brittney A. Grover, William H. |
author_facet | McKenzie, Brittney A. Grover, William H. |
author_sort | McKenzie, Brittney A. |
collection | PubMed |
description | Measuring the temperature of a sample is a fundamental need in many biological and chemical processes. When the volume of the sample is on the microliter or nanoliter scale (e.g., cells, microorganisms, precious samples, or samples in microfluidic devices), accurate measurement of the sample temperature becomes challenging. In this work, we demonstrate a technique for accurately determining the temperature of microliter volumes using a simple 3D-printed microfluidic chip. We accomplish this by first filling “microfluidic thermometer” channels on the chip with substances with precisely known freezing/melting points. We then use a thermoelectric cooler to create a stable and linear temperature gradient along these channels within a measurement region on the chip. A custom software tool (available as online Supporting Information) is then used to find the locations of solid-liquid interfaces in the thermometer channels; these locations have known temperatures equal to the freezing/melting points of the substances in the channels. The software then uses the locations of these interfaces to calculate the temperature at any desired point within the measurement region. Using this approach, the temperature of any microliter-scale on-chip sample can be measured with an uncertainty of about a quarter of a degree Celsius. As a proof-of-concept, we use this technique to measure the unknown freezing point of a 50 microliter volume of solution and demonstrate its feasibility on a 400 nanoliter sample. Additionally, this technique can be used to measure the temperature of any on-chip sample, not just near-zero-Celsius freezing points. We demonstrate this by using an oil that solidifies near room temperature (coconut oil) in a microfluidic thermometer to measure on-chip temperatures well above zero Celsius. By providing a low-cost and simple way to accurately measure temperatures in small volumes, this technique should find applications in both research and educational laboratories. |
format | Online Article Text |
id | pubmed-5746210 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-57462102018-01-08 A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes McKenzie, Brittney A. Grover, William H. PLoS One Research Article Measuring the temperature of a sample is a fundamental need in many biological and chemical processes. When the volume of the sample is on the microliter or nanoliter scale (e.g., cells, microorganisms, precious samples, or samples in microfluidic devices), accurate measurement of the sample temperature becomes challenging. In this work, we demonstrate a technique for accurately determining the temperature of microliter volumes using a simple 3D-printed microfluidic chip. We accomplish this by first filling “microfluidic thermometer” channels on the chip with substances with precisely known freezing/melting points. We then use a thermoelectric cooler to create a stable and linear temperature gradient along these channels within a measurement region on the chip. A custom software tool (available as online Supporting Information) is then used to find the locations of solid-liquid interfaces in the thermometer channels; these locations have known temperatures equal to the freezing/melting points of the substances in the channels. The software then uses the locations of these interfaces to calculate the temperature at any desired point within the measurement region. Using this approach, the temperature of any microliter-scale on-chip sample can be measured with an uncertainty of about a quarter of a degree Celsius. As a proof-of-concept, we use this technique to measure the unknown freezing point of a 50 microliter volume of solution and demonstrate its feasibility on a 400 nanoliter sample. Additionally, this technique can be used to measure the temperature of any on-chip sample, not just near-zero-Celsius freezing points. We demonstrate this by using an oil that solidifies near room temperature (coconut oil) in a microfluidic thermometer to measure on-chip temperatures well above zero Celsius. By providing a low-cost and simple way to accurately measure temperatures in small volumes, this technique should find applications in both research and educational laboratories. Public Library of Science 2017-12-28 /pmc/articles/PMC5746210/ /pubmed/29284028 http://dx.doi.org/10.1371/journal.pone.0189430 Text en © 2017 McKenzie, Grover http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article McKenzie, Brittney A. Grover, William H. A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes |
title | A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes |
title_full | A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes |
title_fullStr | A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes |
title_full_unstemmed | A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes |
title_short | A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes |
title_sort | microfluidic thermometer: precise temperature measurements in microliter- and nanoliter-scale volumes |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5746210/ https://www.ncbi.nlm.nih.gov/pubmed/29284028 http://dx.doi.org/10.1371/journal.pone.0189430 |
work_keys_str_mv | AT mckenziebrittneya amicrofluidicthermometerprecisetemperaturemeasurementsinmicroliterandnanoliterscalevolumes AT groverwilliamh amicrofluidicthermometerprecisetemperaturemeasurementsinmicroliterandnanoliterscalevolumes AT mckenziebrittneya microfluidicthermometerprecisetemperaturemeasurementsinmicroliterandnanoliterscalevolumes AT groverwilliamh microfluidicthermometerprecisetemperaturemeasurementsinmicroliterandnanoliterscalevolumes |