Cargando…

Reference ranges for rotational thromboelastometry in male Sprague Dawley rats

BACKGROUND: A functional coagulation assay was used to investigate the extrinsic pathway of coagulation on citrated whole blood samples from healthy adult male Sprague Dawley rats using the mini cup and pin system. METHODS: Reference values for coagulation parameters from forty-three animals were ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Cruz, Mariana Vigiola, Luker, Jenna N., Carney, Bonnie C., Brummel-Ziedins, Kathleen E., Bravo, Maria-Cristina, Orfeo, Thomas, Chen, Jason H., Moffatt, Lauren T., Shupp, Jeffrey W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5747092/
https://www.ncbi.nlm.nih.gov/pubmed/29299031
http://dx.doi.org/10.1186/s12959-017-0154-0
_version_ 1783289217704525824
author Cruz, Mariana Vigiola
Luker, Jenna N.
Carney, Bonnie C.
Brummel-Ziedins, Kathleen E.
Bravo, Maria-Cristina
Orfeo, Thomas
Chen, Jason H.
Moffatt, Lauren T.
Shupp, Jeffrey W.
author_facet Cruz, Mariana Vigiola
Luker, Jenna N.
Carney, Bonnie C.
Brummel-Ziedins, Kathleen E.
Bravo, Maria-Cristina
Orfeo, Thomas
Chen, Jason H.
Moffatt, Lauren T.
Shupp, Jeffrey W.
author_sort Cruz, Mariana Vigiola
collection PubMed
description BACKGROUND: A functional coagulation assay was used to investigate the extrinsic pathway of coagulation on citrated whole blood samples from healthy adult male Sprague Dawley rats using the mini cup and pin system. METHODS: Reference values for coagulation parameters from forty-three animals were calculated using data obtained from the ROTEM® delta hemostasis analyzer with the EXTEM test. RESULTS: The following ranges, presented as the 2.5–97.5 percentiles, were established: CT [18–77], CFT [20–80], α [73–86], MCF [53–70], and ML [1–22], along with others. CONCLUSIONS: These reference ranges can be used in future studies in rats to identify clinically significant coagulopathies.
format Online
Article
Text
id pubmed-5747092
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-57470922018-01-03 Reference ranges for rotational thromboelastometry in male Sprague Dawley rats Cruz, Mariana Vigiola Luker, Jenna N. Carney, Bonnie C. Brummel-Ziedins, Kathleen E. Bravo, Maria-Cristina Orfeo, Thomas Chen, Jason H. Moffatt, Lauren T. Shupp, Jeffrey W. Thromb J Research BACKGROUND: A functional coagulation assay was used to investigate the extrinsic pathway of coagulation on citrated whole blood samples from healthy adult male Sprague Dawley rats using the mini cup and pin system. METHODS: Reference values for coagulation parameters from forty-three animals were calculated using data obtained from the ROTEM® delta hemostasis analyzer with the EXTEM test. RESULTS: The following ranges, presented as the 2.5–97.5 percentiles, were established: CT [18–77], CFT [20–80], α [73–86], MCF [53–70], and ML [1–22], along with others. CONCLUSIONS: These reference ranges can be used in future studies in rats to identify clinically significant coagulopathies. BioMed Central 2017-12-28 /pmc/articles/PMC5747092/ /pubmed/29299031 http://dx.doi.org/10.1186/s12959-017-0154-0 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Cruz, Mariana Vigiola
Luker, Jenna N.
Carney, Bonnie C.
Brummel-Ziedins, Kathleen E.
Bravo, Maria-Cristina
Orfeo, Thomas
Chen, Jason H.
Moffatt, Lauren T.
Shupp, Jeffrey W.
Reference ranges for rotational thromboelastometry in male Sprague Dawley rats
title Reference ranges for rotational thromboelastometry in male Sprague Dawley rats
title_full Reference ranges for rotational thromboelastometry in male Sprague Dawley rats
title_fullStr Reference ranges for rotational thromboelastometry in male Sprague Dawley rats
title_full_unstemmed Reference ranges for rotational thromboelastometry in male Sprague Dawley rats
title_short Reference ranges for rotational thromboelastometry in male Sprague Dawley rats
title_sort reference ranges for rotational thromboelastometry in male sprague dawley rats
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5747092/
https://www.ncbi.nlm.nih.gov/pubmed/29299031
http://dx.doi.org/10.1186/s12959-017-0154-0
work_keys_str_mv AT cruzmarianavigiola referencerangesforrotationalthromboelastometryinmalespraguedawleyrats
AT lukerjennan referencerangesforrotationalthromboelastometryinmalespraguedawleyrats
AT carneybonniec referencerangesforrotationalthromboelastometryinmalespraguedawleyrats
AT brummelziedinskathleene referencerangesforrotationalthromboelastometryinmalespraguedawleyrats
AT bravomariacristina referencerangesforrotationalthromboelastometryinmalespraguedawleyrats
AT orfeothomas referencerangesforrotationalthromboelastometryinmalespraguedawleyrats
AT chenjasonh referencerangesforrotationalthromboelastometryinmalespraguedawleyrats
AT moffattlaurent referencerangesforrotationalthromboelastometryinmalespraguedawleyrats
AT shuppjeffreyw referencerangesforrotationalthromboelastometryinmalespraguedawleyrats