Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study

BACKGROUND: Application of objective measurement of stroke gait with accelerometer-based wearable technology and associated algorithms is increasing, despite reports questioning the accuracy of this technique in quantifying specific stroke-related gait impairments. The aim of this study is to determ...

Descripción completa

Detalles Bibliográficos
Autores principales: Moore, Sarah A., Hickey, Aodhan, Lord, Sue, Del Din, Silvia, Godfrey, Alan, Rochester, Lynn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5747176/
https://www.ncbi.nlm.nih.gov/pubmed/29284544
http://dx.doi.org/10.1186/s12984-017-0341-z
_version_ 1783289237698772992
author Moore, Sarah A.
Hickey, Aodhan
Lord, Sue
Del Din, Silvia
Godfrey, Alan
Rochester, Lynn
author_facet Moore, Sarah A.
Hickey, Aodhan
Lord, Sue
Del Din, Silvia
Godfrey, Alan
Rochester, Lynn
author_sort Moore, Sarah A.
collection PubMed
description BACKGROUND: Application of objective measurement of stroke gait with accelerometer-based wearable technology and associated algorithms is increasing, despite reports questioning the accuracy of this technique in quantifying specific stroke-related gait impairments. The aim of this study is to determine the feasibility, validity and reliability of a low-cost open-source system incorporating algorithms and a single tri-axial accelerometer-based wearable to quantify gait characteristics in the laboratory and community post-stroke. METHODS: Twenty-five participants with stroke wore the wearable (AX3, Axivity) on the lower back during a laboratory 2 minute continuous walk (preferred pace) on two occasions a week apart and continuously in the community for two consecutive 7 day periods. Video, instrumented walkway (GaitRite) and an OPAL accelerometer-based wearable were used as laboratory references. RESULTS: Feasibility of the proposed system was good. The system was valid for measuring step count (ICC 0.899). Inherent differences in gait quantification between algorithm and GaitRite resulted in difficulties comparing agreement between the different systems. Agreement was moderate-excellent (ICC 0.503–0.936) for mean and variability gait characteristics vs. OPAL. Agreement was moderate-poor between the system and OPAL for asymmetry characteristics. Moderate-excellent reliability (ICC 0.534–0.857) was demonstrated for 11/14 laboratory measured gait characteristics. Community test-retest reliability was good-excellent (ICC 0.867–0.983) for all except one (ICC 0.699) of the 19 gait characteristics. CONCLUSION: The proposed system is a low-cost, reliable tool for quantifying gait post-stroke with multiple potential applications. Further refinement to optimise gait quantification algorithms for certain gait characteristics including gait asymmetry is required.
format Online
Article
Text
id pubmed-5747176
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-57471762018-01-03 Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study Moore, Sarah A. Hickey, Aodhan Lord, Sue Del Din, Silvia Godfrey, Alan Rochester, Lynn J Neuroeng Rehabil Research BACKGROUND: Application of objective measurement of stroke gait with accelerometer-based wearable technology and associated algorithms is increasing, despite reports questioning the accuracy of this technique in quantifying specific stroke-related gait impairments. The aim of this study is to determine the feasibility, validity and reliability of a low-cost open-source system incorporating algorithms and a single tri-axial accelerometer-based wearable to quantify gait characteristics in the laboratory and community post-stroke. METHODS: Twenty-five participants with stroke wore the wearable (AX3, Axivity) on the lower back during a laboratory 2 minute continuous walk (preferred pace) on two occasions a week apart and continuously in the community for two consecutive 7 day periods. Video, instrumented walkway (GaitRite) and an OPAL accelerometer-based wearable were used as laboratory references. RESULTS: Feasibility of the proposed system was good. The system was valid for measuring step count (ICC 0.899). Inherent differences in gait quantification between algorithm and GaitRite resulted in difficulties comparing agreement between the different systems. Agreement was moderate-excellent (ICC 0.503–0.936) for mean and variability gait characteristics vs. OPAL. Agreement was moderate-poor between the system and OPAL for asymmetry characteristics. Moderate-excellent reliability (ICC 0.534–0.857) was demonstrated for 11/14 laboratory measured gait characteristics. Community test-retest reliability was good-excellent (ICC 0.867–0.983) for all except one (ICC 0.699) of the 19 gait characteristics. CONCLUSION: The proposed system is a low-cost, reliable tool for quantifying gait post-stroke with multiple potential applications. Further refinement to optimise gait quantification algorithms for certain gait characteristics including gait asymmetry is required. BioMed Central 2017-12-29 /pmc/articles/PMC5747176/ /pubmed/29284544 http://dx.doi.org/10.1186/s12984-017-0341-z Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Moore, Sarah A.
Hickey, Aodhan
Lord, Sue
Del Din, Silvia
Godfrey, Alan
Rochester, Lynn
Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study
title Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study
title_full Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study
title_fullStr Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study
title_full_unstemmed Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study
title_short Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study
title_sort comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5747176/
https://www.ncbi.nlm.nih.gov/pubmed/29284544
http://dx.doi.org/10.1186/s12984-017-0341-z
work_keys_str_mv AT mooresaraha comprehensivemeasurementofstrokegaitcharacteristicswithasingleaccelerometerinthelaboratoryandcommunityafeasibilityvalidityandreliabilitystudy
AT hickeyaodhan comprehensivemeasurementofstrokegaitcharacteristicswithasingleaccelerometerinthelaboratoryandcommunityafeasibilityvalidityandreliabilitystudy
AT lordsue comprehensivemeasurementofstrokegaitcharacteristicswithasingleaccelerometerinthelaboratoryandcommunityafeasibilityvalidityandreliabilitystudy
AT deldinsilvia comprehensivemeasurementofstrokegaitcharacteristicswithasingleaccelerometerinthelaboratoryandcommunityafeasibilityvalidityandreliabilitystudy
AT godfreyalan comprehensivemeasurementofstrokegaitcharacteristicswithasingleaccelerometerinthelaboratoryandcommunityafeasibilityvalidityandreliabilitystudy
AT rochesterlynn comprehensivemeasurementofstrokegaitcharacteristicswithasingleaccelerometerinthelaboratoryandcommunityafeasibilityvalidityandreliabilitystudy